Reference Guide

Table Of Contents
RAC074
Message Unable to perform the iDRAC reset to factory defaults operation because a vFlash
partition creation operation is in progress.
Detailed
Description
The iDRAC reset to factory defaults operation cannot be completed because a
vflash partition creation operation is in progress.
Recommended
Response Action
Wait for the vFlash partition creation process to complete and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0740
Message The Prepare to Remove operation will stop any activity on the PCIe SSD device so
that it can be removed safely. The device is safe to remove when the disk shows
the safe to remove LED pattern.
Detailed
Description
The Prepare to Remove operation will stop any activity on the PCIe SSD device so
that it can be removed safely. The device is safe to remove when the disk shows
the safe to remove LED pattern.
Recommended
Response Action
Press OK to continue.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0741
Message Unable to perform Prepare to Remove or Secure Erase operations on the selected
PCIe SSD disk drive(s), because Lifecycle Controller is not enabled.
Detailed
Description
Unable to perform Prepare to Remove or Secure Erase operations on the selected
PCIe SSD disk drive(s), because Lifecycle Controller is not enabled. Retry the
operation after the server has restarted.
Recommended
Response Action
To enable Lifecycle Controller, reboot the server. During server startup, press F2 to
enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable,
and save the changes. Retry the operation after the server has restarted.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
1273