Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
RAC0728
Message The Quick Sync communication is no longer functioning.
Detailed
Description
The Quick Sync communication or the connection to the iDRAC is no longer
functioning.
Recommended
Response Action
Do the following: 1) Remove and reseat the bezel. 2) Turn the bezel on by pressing
the activation button. 3) Try the Quick Sync feature again. If the issue persists,
contact your technical support provider.
Category System Health (RAC = RAC Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
RAC073
Message Unable to perform the iDRAC reset operation because a vFlash partition creation
operation is in progress.
Detailed
Description
The iDRAC reset operation cannot be completed because a vFlash partition
creation operation is in progress.
Recommended
Response Action
Wait for the vFlash partition creation process to complete and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
1272