Reference Guide

Table Of Contents
Recommended
Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider.
Category System Health (AMP = Amperage)
Severity Severity 1 (Critical)
OMSA Event ID 5200
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
AMP401
Message Unable to read the arg1 sensor value.
Arguments arg1 = sensor name
Detailed
Description
The current sensor identified in the message has failed. This condition can cause
system performance issues and degradation in the monitoring capability of the
system.
Recommended
Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider.
Category System Health (AMP = Amperage)
Severity Severity 2 (Warning)
OMSA Event ID 5201
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
127