Reference Guide

Table Of Contents
Recommended
Response Action
Reset the iDRAC user credentials and BIOS passwords to default and retry the
operation.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0681
Message Shared component updates through the Server OS or Lifecycle controller cannot
be applied because the CMC setting for Chassis Management at Server Mode is not
set to Manage and Monitor.
Detailed
Description
Shared component updates through the Server OS or Lifecycle controller cannot
be applied because the CMC setting for Chassis Management at Server Mode is not
set to Manage and Monitor.
Recommended
Response Action
To enable this feature do the following: 1) Launch CMC Web UI. 2) Navigate to
Chassis Overview -> Setup -> General, and select Manage and Monitor option for
the Chassis Management at Server Mode. 3) Click Apply to save changes in CMC. 4)
Retry the operation in iDRAC. For more information, refer to the CMC User Guide.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0682
Message Enabling iDRAC Direct USB Configuration XML allows any USB key containing a
correctly formatted configuration XML file to reconfigure the server when plugged
into the USB management port identified by the wrench icon. This may include
operations on RAID configurations, user accounts, and alert settings.
Detailed
Description
Enabling iDRAC Direct USB Configuration XML allows any USB key containing a
correctly formatted configuration XML file to reconfigure the server when plugged
into the USB management port identified by the wrench icon. This may include
operations on RAID configurations, user accounts, and alert settings.
Recommended
Response Action
No response action is required.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
1250