Reference Guide

Table Of Contents
Recommended
Response Action
Do one of the following and retry the operation: 1) If there are no disk drives
available in ready state, insert additional disk drives and make sure the drives are in
ready state. 2) If no virtual disks are present, click <create virtualdisk link> and
create at least one virtual disk. 3) If the physical disk drive(s) are in non-RAID mode,
convert them to RAID mode by pressing Ctrl+R while restarting the server, and
then select the required controller. Press F2 and select the Convert to RAID
capable option, and then complete the operation.
Category Storage (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0677
Message No physical disk drives in ready state, no virtual disks are created, and no PCIe SSD
drives are available to perform operations on.
Detailed
Description
No physical disk drives in ready state, virtual disks, or PCIe SSD drives are available
to perform operations on.
Recommended
Response Action
Do one of the following: 1. If there are no disk drives available in ready state, insert
additional disk drives and make sure the drives are in ready state. 2. If no virtual
disks are present, click <create virtualdisk link> and create at least one virtual disk.
3. If PCIe SSD drives are inserted into the enclosure or attached to the backplane.
Category Storage (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0678
Message Unable to perform Prepare to Remove or Secure Erase operations on PCIe SSD disk
drives.
Detailed
Description
Unable to perform Prepare to Remove or Secure Erase operations on the PCIe SSD
disk drives.
Recommended
Response Action
Make sure PCIe SSD disk drives are inserted into the enclosure or attached to the
backplane and retry the operation. If the issue persists, contact your service
provider.
Category Storage (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
1248