This setting will be applied during the next server restart. If the setting is not
compatible with the RAID Controller, then LED status indicators on all the
associated hard disk drives (HDDs) stop functioning.
Recommended
Response Action
Press OK to continue.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0669
Message Initializing the virtual disk will permanently delete data from the virtual disk.
Detailed
Description
Initializing the virtual disk will permanently delete data from the virtual disk.
Recommended
Response Action
Press OK to continue.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC067
Message iDRAC reset to factory defaults operation was not successful.
Detailed
Description
iDRAC reset to factory defaults operation was not successful. This may be due to
IPMI communications issues.
Recommended
Response Action
Do the following: 1) Retry the operation. 2) If the issue persists, remove AC input
power from the server and re-apply AC power to the server and retry the
operation. 3) If the issue continues to persist, contact your service provider.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0670
Message Deleting the virtual disk will remove the virtual disk from the controllers
configuration.
Detailed
Description
Deleting the virtual disk will remove the virtual disk from the controllers
configuration. If the specified virtual disk is a boot device, the server will not boot
unless another boot device is selected in BIOS.
1245