Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
RAC0561
Message iDRAC to CMC communication link is not functioning for agent free monitoring of
chassis PCIe slots.
Detailed
Description
iDRAC lost connection with CMC proxy component that enables agent free
monitoring of PCIe slots. Agent free monitoring will not be supported for Chassis
PCIe slots while this connection is not functioning.
Recommended
Response Action
Do the following: 1) Check the Lifecycle Log for the subsequent RAC0562
communications restored message that will indicate the link was re-established
automatically. 2) If there is no subsequent RAC0562 message in the Lifecycle Log,
restart the iDRAC. The iDRAC can be restarted by using the RACADM command
line utility and entering "racadm racreset". 3) After the iDRAC has restarted, if the
communications link is still not functioning, restart the CMC and check the
Lifecycle Log for this link error after the CMC has restarted. 4) If the issue persists,
contact your service provider.
Category System Health (RAC = RAC Event)
Severity Severity 3 (Informational)
Trap/EventID 2531
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
1220