Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
RAC052
Message Unable to create a configuration job because an existing configuration job is
already in progress.
Detailed
Description
Unable to create a configuration job because an existing configuration job is
already in progress. Only one configuration job for a component can run or can be
processed at any time.
Recommended
Response Action
Retry the operation after the existing configuration job is complete, or cancel the
existing configuration job and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC053
Message OS to iDRAC pass-through is disabled.
Detailed
Description
One or more attributes being set are dependent on OS to iDRAC pass-through
being enabled.
Recommended
Response Action
Enable OS to iDRAC pass-through and retry the previous command.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC054
Message User account attributes cannot be reset to default values due to an internal error.
Detailed
Description
The user account attributes cannot be reset to default values due to an internal
error.
Recommended
Response Action
Make sure the configuration XML file contains valid values for user account
attributes and retry the operation.
Category Configuration (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
1218