Reference Guide

Table Of Contents
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0514
Message Unable to create virtual disk(s) on the selected controller.
Detailed
Description
Virtual disk(s) cannot be created because of one or more reasons identified in the
Recommended Response Action.
Recommended
Response Action
Check the following: 1) If no physical disk drives are available for virtual disk (VD)
creation, install additional physical disk drives. 2) If the maximum number of VDs
that can be created on the controller has been reached, a new VD cannot be
created until an existing VD is deleted. 3) If the maximum number of VDs supported
by drive group has been created, a new VD cannot be created until an existing VD
is deleted from the selected drive group. 4) If the physical disk drive(s) are in non-
RAID mode, convert them to RAID mode by pressing Ctrl+R while restarting the
server, and then select the required controller. Press F2 and select the Convert to
RAID capable option, and then complete the operation. 5) If a job is currently
running or scheduled on the selected controller, the job must be completed or
deleted before attempting a new operation. Status of the scheduled job can be
viewed and managed on the Job Queue page on iDRAC. Click Job Queue link to
view the status of the scheduled jobs.
Category Storage (RAC = RAC Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
RAC0516
Message Converting physical disk drives to RAID-compatible will overwrite any OS-created
RAID arrays.
Detailed
Description
Converting physical disk drives to RAID-compatible will overwrite any OS-created
RAID arrays.
Recommended
Response Action
Make sure that there are no OS-configured RAID arrays, and then click OK.
Category Storage (RAC = RAC Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
1217