Reference Guide

Table Of Contents
Detailed
Description
Physical disks cannot be displayed. This error may occur if the host system is
powered off, physical disks are removed, or incorrect filters are applied.
Recommended
Response Action
1. Check if the host system is powered off or shutdown. 2. Check if the physical
disks are inserted into the enclosure or attached to the backplane. 3. Check if
correct filters are applied. 4. Check that the Storage Enclosure is on. 5. verify that
the adapter cables are properly connected and there are no bent pins.
Category Storage (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0512
Message There are no virtual disks to be displayed.
Detailed
Description
Virtual disks cannot be displayed. This error may occur if the host system is
powered off, no virtual disks were created, or incorrect filters are applied.
Recommended
Response Action
1. Check if the host system is ON. 2. Check if virtual disks are created. 3. Check if
correct filters are applied. 4. Check if the Storage Enclosure is ON. 5. Verify that the
adapter cables are properly connected and there are no bent pins.
Category Storage (RAC = RAC Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
RAC0513
Message There are no virtual disks to be displayed.
Detailed
Description
There are no virtual disks to be displayed. There may be no virtual disks created, the
controller(s) may not be in RAID mode, or there may be pending creation or
deletion jobs that have not completed.
Recommended
Response Action
Check the following: 1) Check if the server is turned off. If the server is turned off,
turn it on and wait until POST completes. 2) If no virtual disks are created, to start
the virtual disk creation process, click #{create_virtualdisk_link}. 3) If create virtual
disk operation(s) are in a pending state, complete the creation process. To
complete the virtual disk(s) creation, go to the Pending Operations page and create
a configuration job on the appropriate controller. 4) If delete virtual disk
operation(s) are in pending state, then cancel the operation. To cancel delete
virtual disk pending operation(s), go to the Pending Operations page and delete all
pending operation(s) on the appropriate controller. 5) If the Controller(s) are in HBA
mode, switch the controller(s) to RAID mode. To switch controller(s) to RAID mode
using the F2 System Setup utility, go to Device Settings > RAID Controller >
Controller Management > Advanced Controller Management > Switch to RAID
mode.
Category Storage (RAC = RAC Event)
1216