Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PWR8528
Message Unable to set Max Power Conservation Mode because the Server Based Power
Management mode is enabled.
Detailed
Description
The Max Power Conservation Mode can be enabled only when Server Based Power
Management Mode is disabled.
Recommended
Response Action
The Max Power Conservation Mode can be changed when Server Based Power
Management mode is disabled. Using the CMC Web UI, navigate to the Chassis
Overview > Power > Configuration page, then uncheck the Enable Server Based
Power Management checkbox. Retry the operation.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PWR8529
Message Max Power Conservation Mode is enabled.
Detailed
Description
The Max Power Conservation Mode is enabled.
Recommended
Response Action
No response action is required.
Category Audit (PWR = Power Usage)
Severity Severity 3 (Informational)