Reference Guide

Table Of Contents
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PWR8508
Message New power budget ( arg1 W AC) may permit future degradation of redundancy.
Arguments arg1 = power value
Detailed
Description
If the power budget exceeds the effective capacity for the current redundancy
policy, it is possible for power allocations to grow beyond the effective capacity,
which would reduce redundancy capabilities.
Recommended
Response Action
No response action is required. Make sure there are enough PSUs to support
redundancy at the specified power budget.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PWR8509
Message Unable to change the server power priority because Server Based Power
Management mode is enabled.
Detailed
Description
Unable to change the server power priority because Server Based Power
Management mode is enabled.
1139