Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PWR2401
Message Power management firmware initialization error
Detailed
Description
The iDRAC controller detected that the power management firmware did not
initialize properly. The system may operate in a performance degraded state.
Recommended
Response Action
"1) Disconnect system input power, wait one minute, reconnect system input
power. 2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest revision."
Category System Health (PWR = Power Usage)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PWR2402
Message iDRAC is unable to communicate with power management firmware.
Detailed
Description
The iDRAC controller cannot communicate with the power management firmware
due to an problem with the interface to the power management engine or with the
power management engine itself. The system may operate in a performance
degraded state.
Recommended
Response Action
Check the Lifecycle Controller Log (LC Log) and make sure that there are no
subsequent log entries indicating that Communication with power management
firmware has been restored. If this log entry is not present then do one of the
following: 1) Disconnect system input power, wait one minute, reconnect system
1132