Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PWR2254
Message The use of 110V is unacknowledged and the chassis cannot grant power on
permission to the server.
Detailed
Description
The use of 110V is unacknowledged for the chassis and the chassis cannot grant
power on permission to the server.
Recommended
Response Action
Check for unacknowledged use of 110V and change to acknowledged. Using the
Chassis Management Controller (CMC) web interface, select Chassis
Overview>Power>Configuration and then check the 110V Acknowledge field. Retry
the operation to turn on the server.
Category Audit (PWR = Power Usage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PWR2255
Message The Chassis Management Controller (CMC) is configured in Max Power
Conservation Mode and is unable to grant power on permission to the server.
Detailed
Description
The Chassis Management Controller (CMC) is configured in Max Power
Conservation Mode and is unable to grant power on permission to the server.
Recommended
Response Action
Disable the Max Power Conservation Mode on the chassis and retry the operation.
Using the Chassis Management Controller (CMC) web interface, select Chassis
1126