Reference Guide

Table Of Contents
Detailed
Description
Unable to set the chassis redundancy policy to AC Redundancy.
Recommended
Response Action
Retry the operation using the CMC command line interface or CMC Web interface.
To set the chassis redundancy policy using the command line, enter "racadm
config -g cfgChassisPower -o cfgChassisRedundancyPolicy 1". To configure the
chassis redundancy policy using the Web interface, click Chassis Overview > Power
> Configuration. From the Redundancy drop-down menu, select AC Redundancy.
Category Audit (PSU = Power Supply)
Severity Severity 1 (Critical)
Trap/EventID 8329
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
PSU8506
Message Unable to change power cap because Server Based Power Management Mode is
enabled.
Detailed
Description
When the Server Power Management mode is enabled the Power cap cannot be
set.
Recommended
Response Action
To enable the ability to set the power cap, switch to external Power Management
and disable the Server Based Management Mode in the CMC Web interface.
Category Audit (PSU = Power Supply)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
1082