Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PSU8502
Message The PSU in slot arg1 detected 110 VAC input voltage and does not match chassis
configuration.
Arguments arg1 = slot number
Detailed
Description
The input voltage of the PSU specified in the message does not match the input
voltage of the PSUs already present in the chassis.
Recommended
Response Action
Do the following: 1) Check the power configuration "Allow 110 VAC Operation"
setting and make sure it is enabled. 2) Check if the input voltage of all the PSUs are
the same. 3) If the input voltage of the PSU specified in the message is not the
same, then remove the unmatched PSU.
Category Audit (PSU = Power Supply)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PSU8503
Message The PSU in slot arg1 detected 220 VAC input voltage and does not match chassis
configuration.
Arguments arg1 = slot number
Detailed
Description
The input voltage of the PSU specified in the message does not match the input
voltage of the PSUs already present in the chassis.
1080