Reference Guide

Table Of Contents
Recommended
Response Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2)
Reconnect the power cable to the power supply unit. 3) Install a new power supply
unit 4) Restore the input power supply.
Category System Health (PSU = Power Supply)
Severity Severity 1 (Critical)
OMSA Event ID 5352
OMSA Trap ID 5352
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PSU1010
Message The DC power supply is switched off.
Detailed
Description
The power supply unit is switched off. Either you have switched off the power
supply unit or it is defective.
Recommended
Response Action
Check to see whether the power switch is turned off or on. If it is turned off, turn it
on. If the problem is not corrected, verify that the power cord is attached and
functional. If the problem continues or if the power switch is already turned on,
then replace the power supply unit.
Category Storage (PSU = Power Supply)
Severity Severity 1 (Critical)
Trap/EventID 4233
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
1076