Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PSU1007
Message arg1 has failed.
Arguments arg1 = PSU Sensor Name
Detailed
Description
A device has been failed and the system is no longer functioning in optimal
condition.
Recommended
Response Action
Replace the device.
Category Storage (PSU = Power Supply)
Severity Severity 1 (Critical)
Trap/EventID 4233
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PSU101
Message Power supply arg1 is not present.
Arguments arg1 = power supply unit
Detailed
Description
The power supply unit identified in the message is not present, because of the one
of the following reasons: 1) The power supply unit is not correctly seated. 2) The
power cable may not be connected properly or disconnected. 3) The power supply
unit has failed. 4) There is an input power failure.
1075