Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PSU1002
Message arg1 was removed
Arguments arg1 = PSU Sensor Name
Detailed
Description
The enclosure detected that a power supply unit was removed and is no longer
functioning in optimal condition.
Recommended
Response Action
Re-insert the power supply unit into the enclosure. Re-connect the AC power
cable and switch on the power supply unit. Contact technical support if the issue
persists.
Category Storage (PSU = Power Supply)
Severity Severity 1 (Critical)
Trap/EventID 4233
OMSA Event ID 2324
OMSA Trap ID 100400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
PSU1003
Message arg1 is switched OFF.
Arguments arg1 = PSU Sensor Name
Detailed
Description
The power supply is not providing any power. This may be because the power
supply switch is in the off position or the power supply has failed.
Recommended
Response Action
Check whether the power switch on the power supply unit is turned off or on. If it
is turned off, turn it on. If the problem is not corrected, verify that the power cord is
attached and functional. See the storage hardware documentation for more
information.
1072