Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PSU100
Message Power supply arg1 is offline.
Arguments arg1 = power supply unit
Detailed
Description
The power supply unit identified in the message is offline, because of the one of
the following reasons: 1) The power supply unit is not correctly seated. 2) The
power cable may not be connected properly or disconnected. 3) The power supply
unit has failed. 4) There is an input power failure.
Recommended
Response Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2)
Reconnect the power cable to the power supply unit. 3) Install a new power supply
unit 4) Restore the input power supply.
Category System Health (PSU = Power Supply)
Severity Severity 2 (Warning)
OMSA Event ID 5303
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PSU1000
Message Power supply cable has been removed from arg1 .
Arguments arg1 = PSU Sensor Name
1070