Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PSU0913
Message Power unit arg1 is operating normally.
Arguments arg1 = number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health (PSU = Power Supply)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PSU0914
Message A predictive failure detected on power unit arg1 .
Arguments arg1 = number
Detailed
Description
Status from the power supply indicates a power supply exception occurred. The
power supply will try to operate. System Performance and power redundancy may
be degraded or lost.
Recommended
Response Action
Remove input power and re-install supply at the next service window.
Category System Health (PSU = Power Supply)
Severity Severity 2 (Warning)
OMSA Event ID 5353
OMSA Trap ID 5353
1069