Reference Guide

Table Of Contents
Recommended
Response Action
Remove and reapply input power. If the problem persists, contact technical
support. Refer to the product documentation to choose a convenient contact
method.
Category System Health (PST = BIOS POST)
Severity Severity 1 (Critical)
Trap/EventID 2425
LCD Message Parity error. Power cycle system
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PST0138
Message SuperIO failed.
Detailed
Description
System BIOS detected a failure with the SIO. This exception occurred early in
system power on, thus the system may not display video. (BIOS POST code
exception code 8A)
Recommended
Response Action
Remove and reapply input power. If the problem persists, contact technical
support. Refer to the product documentation to choose a convenient contact
method.
Category System Health (PST = BIOS POST)
Severity Severity 1 (Critical)
Trap/EventID 2425
LCD Message SuperIO failure. Power cycle system
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
1030