Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PST0080
Message An issue was detected. System at boot F1/F2 prompt. Requires entry to continue.
Detailed
Description
System is at the F1/F2 prompt because the system BIOS detected an issue other
than "No bootable devices".
Recommended
Response Action
Check post display screen for details. Press F1 to continue boot, or press F2 to go
to setup.
Category System Health (PST = BIOS POST)
Severity Severity 2 (Warning)
LCD Message System BIOS at F1/F2 prompt.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PST0081
Message No bootable devices.
Detailed
Description
System is at F1/F2 prompt because the system BIOS was unable to detect a
bootable device.
Recommended
Response Action
Make sure a bootable device is attached to the system and enabled in BIOS setup.
If device is attached and enabled, remove and reapply power to server. If the
problem persists, contact your service provider. Refer to the product
documentation to choose a convenient contact method.
Category System Health (PST = BIOS POST)
1017