Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PR34
Message arg1 failed after exceeding retry attempt limit.
Arguments arg1 = job ID
Detailed
Description
The job was attempted but failed unexpectedly. An AC Power loss, system crash, or
other interruption during the job processing can cause this failure.
Recommended
Response Action
Recreate and resubmit the job.
Category Configuration (PR = Part Exchange)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PR35
Message Power Supply slot arg1 firmware update will be performed during next system
reboot.
Arguments arg1 = PS slot number
Detailed
Description
The Part Replacement feature has detected a firmware difference for the power
supply and will start the firmware update process upon system reboot.
Recommended
Response Action
No response action is required.
Category Configuration (PR = Part Exchange)
Severity Severity 3 (Informational)
1003