Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 AMP Event Messages........................................................................................ 113 AMP0300........................................................................................................................................... 113 AMP0301............................................................................................................................................ 113 AMP0302................................................................................
ASR0009............................................................................................................................................ 133 ASR0100............................................................................................................................................ 134 ASR0101............................................................................................................................................. 134 ASR0102................................................
BAR026.............................................................................................................................................. 155 BAR027.............................................................................................................................................. 156 BAR028.............................................................................................................................................. 156 BAR029...............................................
BAR068.............................................................................................................................................. 177 BAR069.............................................................................................................................................. 177 BAR070.............................................................................................................................................. 178 BAR071...............................................
BAR110...............................................................................................................................................198 BAR111............................................................................................................................................... 199 BAR112............................................................................................................................................... 199 BAR113.............................................
BAT1010............................................................................................................................................ 223 BAT1011............................................................................................................................................. 223 BAT1012.............................................................................................................................................224 BAT1013................................................
BIOS014............................................................................................................................................ 246 BIOS015.............................................................................................................................................247 BIOS016.............................................................................................................................................247 BIOS017.................................................
CBL0002........................................................................................................................................... 262 CBL0003........................................................................................................................................... 263 CBL0004........................................................................................................................................... 263 CBL0005....................................................
CMC8527.......................................................................................................................................... 285 CMC8528.......................................................................................................................................... 285 CMC8529.......................................................................................................................................... 286 CMC8531.......................................................
CMC8579.......................................................................................................................................... 307 CMC8601.......................................................................................................................................... 307 CMC8602..........................................................................................................................................308 CMC8603........................................................
CPU9000...........................................................................................................................................332 10 CPUA Event Messages................................................................................... 333 CPUA0023.........................................................................................................................................333 11 CTL Event Messages................................................................................
CTL24................................................................................................................................................ 355 CTL25................................................................................................................................................ 356 CTL26................................................................................................................................................ 357 CTL27.............................................
CTL62................................................................................................................................................ 382 CTL63................................................................................................................................................ 383 CTL64................................................................................................................................................ 383 CTL65.............................................
12 DH Event Messages........................................................................................407 DH001............................................................................................................................................... 407 DH002...............................................................................................................................................407 DH003..........................................................................................
DIAG0212.......................................................................................................................................... 423 DIAG0213.......................................................................................................................................... 423 DIAG0221.......................................................................................................................................... 424 DIAG0232...................................................
DIAG8006......................................................................................................................................... 440 DIAG8007......................................................................................................................................... 440 DIAG8008..........................................................................................................................................441 DIAG8009......................................................
DIS009.............................................................................................................................................. 458 DIS010............................................................................................................................................... 458 DIS011................................................................................................................................................459 DIS012.............................................
ENC22............................................................................................................................................... 480 ENC23................................................................................................................................................481 ENC24............................................................................................................................................... 482 ENC25................................................
FAN0003........................................................................................................................................... 504 FAN0004........................................................................................................................................... 505 FAN0005........................................................................................................................................... 506 FAN0006....................................................
19 FC Event Messages.........................................................................................528 FC001................................................................................................................................................ 528 FC002................................................................................................................................................528 FC003.......................................................................................
FLDC1014.......................................................................................................................................... 546 FLDC1015.......................................................................................................................................... 547 FLDC1016.......................................................................................................................................... 547 FLDC1017...................................................
HWC0010..........................................................................................................................................570 HWC0011........................................................................................................................................... 571 HWC0012...........................................................................................................................................571 HWC0013.......................................................
HWC2009......................................................................................................................................... 593 HWC2010..........................................................................................................................................594 HWC2011.......................................................................................................................................... 594 HWC2012.........................................................
HWC5035.......................................................................................................................................... 616 HWC5036.......................................................................................................................................... 616 HWC5037...........................................................................................................................................617 HWC6000.......................................................
IOID005.............................................................................................................................................639 IOID006............................................................................................................................................ 639 IOID110............................................................................................................................................. 640 IOID111................................................
IOV103.............................................................................................................................................. 660 IOV104.............................................................................................................................................. 660 IOV105............................................................................................................................................... 661 IOV106..............................................
ISM0010............................................................................................................................................ 679 ISM0011.............................................................................................................................................680 ISM0012............................................................................................................................................ 680 ISM0013.................................................
JCP026............................................................................................................................................. 694 JCP027..............................................................................................................................................694 JCP028..............................................................................................................................................695 JCP029..................................................
LC031.................................................................................................................................................707 LC032................................................................................................................................................ 708 LC033................................................................................................................................................ 708 LC034.............................................
LC073................................................................................................................................................ 720 LC074.................................................................................................................................................721 LC075................................................................................................................................................. 721 LC076............................................
LIC212................................................................................................................................................736 LIC213................................................................................................................................................ 737 LIC501................................................................................................................................................ 737 LIC502..........................................
LOG320............................................................................................................................................. 754 LOG321..............................................................................................................................................754 LOG322..............................................................................................................................................755 LOG323..................................................
MEM0702...........................................................................................................................................774 MEM1000...........................................................................................................................................775 MEM1001........................................................................................................................................... 775 MEM1002......................................................
MEM8500.......................................................................................................................................... 798 MEM8501...........................................................................................................................................798 MEM8502.......................................................................................................................................... 799 MEM9000.......................................................
NIC500.............................................................................................................................................. 816 NIC501...............................................................................................................................................816 NIC502.............................................................................................................................................. 816 NIC503...............................................
OSD27............................................................................................................................................... 830 OSD28...............................................................................................................................................830 OSD29...............................................................................................................................................830 OSD3...................................................
OSD65............................................................................................................................................... 842 OSD7................................................................................................................................................. 843 OSD8................................................................................................................................................. 843 OSD9...............................................
PCI1342............................................................................................................................................. 863 PCI1344............................................................................................................................................. 863 PCI1346.............................................................................................................................................864 PCI1348...............................................
PCI5008............................................................................................................................................ 887 PCI5009............................................................................................................................................ 888 38 PDR Event Messages..................................................................................... 889 PDR1............................................................................................
PDR1107............................................................................................................................................. 911 PDR1108.............................................................................................................................................911 PDR111............................................................................................................................................... 912 PDR1116..............................................
PDR27................................................................................................................................................936 PDR28................................................................................................................................................937 PDR29............................................................................................................................................... 938 PDR3.................................................
PDR66............................................................................................................................................... 963 PDR67................................................................................................................................................964 PDR68............................................................................................................................................... 964 PDR69................................................
POW002............................................................................................................................................986 POW003............................................................................................................................................986 POW004............................................................................................................................................987 POW005........................................................
42 PST Event Messages.................................................................................... 1008 PST0000......................................................................................................................................... 1008 PST0001..........................................................................................................................................1008 PST0002..............................................................................................
PST0137...........................................................................................................................................1029 PST0138.......................................................................................................................................... 1030 PST0139........................................................................................................................................... 1031 PST0140...................................................
PSU0042......................................................................................................................................... 1054 PSU0043......................................................................................................................................... 1054 PSU0044......................................................................................................................................... 1055 PSU0045.......................................................
PSU500............................................................................................................................................1078 PSU501............................................................................................................................................ 1078 PSU502............................................................................................................................................1078 PSU503....................................................
PWR1001......................................................................................................................................... 1098 PWR1002.........................................................................................................................................1099 PWR1003.........................................................................................................................................1099 PWR1004.........................................................
PWR2209......................................................................................................................................... 1120 PWR221............................................................................................................................................ 1121 PWR2210.......................................................................................................................................... 1121 PWR2211....................................................
PWR8516..........................................................................................................................................1142 PWR8517..........................................................................................................................................1143 PWR8518......................................................................................................................................... 1144 PWR8519.......................................................
RAC011............................................................................................................................................ 1160 RAC0113.......................................................................................................................................... 1160 RAC0115........................................................................................................................................... 1161 RAC0116..................................................
RAC016............................................................................................................................................ 1173 RAC0160.......................................................................................................................................... 1173 RAC0169.......................................................................................................................................... 1173 RAC017....................................................
RAC0241.......................................................................................................................................... 1185 RAC0242..........................................................................................................................................1186 RAC0243..........................................................................................................................................1186 RAC0244......................................................
RAC0281.......................................................................................................................................... 1198 RAC0282..........................................................................................................................................1198 RAC0283..........................................................................................................................................1199 RAC0284......................................................
RAC049............................................................................................................................................ 1211 RAC050............................................................................................................................................ 1211 RAC0500..........................................................................................................................................1212 RAC0501...................................................
RAC0610......................................................................................................................................... 1226 RAC0611.......................................................................................................................................... 1226 RAC0612..........................................................................................................................................1226 RAC0613......................................................
RAC0649......................................................................................................................................... 1239 RAC065........................................................................................................................................... 1239 RAC0654......................................................................................................................................... 1239 RAC0655......................................................
RAC0692......................................................................................................................................... 1254 RAC0693......................................................................................................................................... 1254 RAC0694......................................................................................................................................... 1254 RAC0695.......................................................
RAC0740..........................................................................................................................................1273 RAC0741.......................................................................................................................................... 1273 RAC0742..........................................................................................................................................1274 RAC0743......................................................
RAC1001..........................................................................................................................................1288 RAC1002......................................................................................................................................... 1289 RAC1003......................................................................................................................................... 1289 RAC1004.......................................................
RAC1045......................................................................................................................................... 1309 RAC1046..........................................................................................................................................1310 RAC1047.......................................................................................................................................... 1310 RAC1048......................................................
RAC1123........................................................................................................................................... 1331 RAC1128.......................................................................................................................................... 1332 RAC1129.......................................................................................................................................... 1332 RAC1130...................................................
RAC1176...........................................................................................................................................1353 RAC1177...........................................................................................................................................1354 RAC1178.......................................................................................................................................... 1354 RAC1179....................................................
RAC945............................................................................................................................................ 1371 RAC946............................................................................................................................................1372 RAC947............................................................................................................................................ 1372 RAC948...................................................
RAC988........................................................................................................................................... 1392 RAC989........................................................................................................................................... 1393 RAC990........................................................................................................................................... 1393 RAC991.....................................................
RDU8509......................................................................................................................................... 1415 RDU8510..........................................................................................................................................1416 RDU8511.......................................................................................................................................... 1416 RDU8512......................................................
RED023............................................................................................................................................1437 RED024........................................................................................................................................... 1438 RED025............................................................................................................................................1438 RED026.....................................................
RED065............................................................................................................................................1461 RED066............................................................................................................................................1461 RED067............................................................................................................................................1462 RED068.....................................................
RFL2008.......................................................................................................................................... 1479 RFL2009.......................................................................................................................................... 1479 50 RFLA Event Messages.................................................................................. 1481 RFLA2001...........................................................................................
RSI0004...........................................................................................................................................1499 54 SEC Event Messages.................................................................................... 1500 SEC0000......................................................................................................................................... 1500 SEC0001............................................................................................
SEC0610..........................................................................................................................................1520 SEC0611........................................................................................................................................... 1521 SEC0612...........................................................................................................................................1521 SEC0613....................................................
SEL1500........................................................................................................................................... 1541 SEL1501........................................................................................................................................... 1542 SEL1502........................................................................................................................................... 1542 SEL1503.................................................
STOR0106........................................................................................................................................1561 STOR0107........................................................................................................................................1562 STOR0108....................................................................................................................................... 1562 STOR0109.........................................................
STOR035..........................................................................................................................................1578 STOR037..........................................................................................................................................1579 STOR038......................................................................................................................................... 1579 STOR039.......................................................
STOR064......................................................................................................................................... 1595 STOR065......................................................................................................................................... 1595 STOR066......................................................................................................................................... 1596 STOR067.......................................................
STOR3.............................................................................................................................................. 1614 STOR300..........................................................................................................................................1615 STOR301.......................................................................................................................................... 1615 STOR302...................................................
SUP0115.......................................................................................................................................... 1629 SUP0116.......................................................................................................................................... 1629 SUP0117...........................................................................................................................................1629 SUP0118....................................................
SUP0511.......................................................................................................................................... 1643 SUP0513.......................................................................................................................................... 1644 SUP0514..........................................................................................................................................1644 SUP0515.....................................................
SWC0001........................................................................................................................................ 1664 SWC0002........................................................................................................................................ 1665 SWC0003........................................................................................................................................ 1665 SWC0004..........................................................
SWC0048........................................................................................................................................ 1685 SWC0049........................................................................................................................................ 1686 SWC0050........................................................................................................................................ 1686 SWC0051..........................................................
SWC0113......................................................................................................................................... 1704 SWC0114......................................................................................................................................... 1705 SWC0115......................................................................................................................................... 1705 SWC0116.......................................................
SWC0155.......................................................................................................................................... 1717 SWC0156..........................................................................................................................................1717 SWC0157..........................................................................................................................................1718 SWC0158......................................................
SWC0236.........................................................................................................................................1730 SWC0237.........................................................................................................................................1730 SWC0238.........................................................................................................................................1730 SWC0239..........................................................
SWC0278.........................................................................................................................................1742 SWC0279.........................................................................................................................................1743 SWC0280........................................................................................................................................ 1743 SWC0281..........................................................
SWC0320.........................................................................................................................................1755 SWC0321......................................................................................................................................... 1756 SWC0322.........................................................................................................................................1756 SWC0323.........................................................
SWC4009.........................................................................................................................................1774 SWC4010......................................................................................................................................... 1775 SWC4011..........................................................................................................................................1775 SWC4012........................................................
SWC8530.........................................................................................................................................1796 SWC8531......................................................................................................................................... 1797 SWC8532......................................................................................................................................... 1797 SWC8533........................................................
SWU8500.........................................................................................................................................1819 SWU8501.........................................................................................................................................1820 SWU8502........................................................................................................................................ 1820 SWU8503..........................................................
SWU8549........................................................................................................................................ 1842 SWU8550........................................................................................................................................ 1842 SWU8551......................................................................................................................................... 1843 SWU8552.........................................................
SYS030............................................................................................................................................ 1858 SYS031.............................................................................................................................................1858 SYS032.............................................................................................................................................1859 SYS033..................................................
SYS073............................................................................................................................................ 1880 SYS074............................................................................................................................................ 1880 SYS075............................................................................................................................................. 1881 SYS076.................................................
SYS111.............................................................................................................................................. 1897 SYS112..............................................................................................................................................1897 SYS113............................................................................................................................................. 1898 SYS114..............................................
SYS153..............................................................................................................................................1919 SYS154............................................................................................................................................. 1919 SYS155............................................................................................................................................. 1920 SYS156...............................................
62 TMP Event Messages................................................................................... 1937 TMP0100......................................................................................................................................... 1937 TMP0101..........................................................................................................................................1937 TMP0102...............................................................................................
TMP0201......................................................................................................................................... 1959 TMP0202.........................................................................................................................................1959 TMP0203.........................................................................................................................................1960 TMP0204.........................................................
UEFI0000........................................................................................................................................ 1980 UEFI0001.........................................................................................................................................1980 UEFI0004.........................................................................................................................................1981 UEFI0005......................................................
UEFI0044........................................................................................................................................2002 UEFI0045........................................................................................................................................ 2002 UEFI0046........................................................................................................................................2003 UEFI0047........................................................
UEFI0086........................................................................................................................................ 2024 UEFI0087........................................................................................................................................ 2025 UEFI0088........................................................................................................................................ 2025 UEFI0089......................................................
UEFI0128.........................................................................................................................................2047 UEFI0129.........................................................................................................................................2047 UEFI0130........................................................................................................................................ 2048 UEFI0131......................................................
UEFI0170.........................................................................................................................................2070 UEFI0171.......................................................................................................................................... 2071 UEFI0172..........................................................................................................................................2071 UEFI0173...................................................
UEFI0212.........................................................................................................................................2094 UEFI0213.........................................................................................................................................2094 UEFI0214.........................................................................................................................................2095 UEFI0215......................................................
UEFI0254..........................................................................................................................................2117 UEFI0255......................................................................................................................................... 2118 UEFI0256......................................................................................................................................... 2118 UEFI0257...................................................
USR0034..........................................................................................................................................2135 USR0150.......................................................................................................................................... 2135 USR0151...........................................................................................................................................2136 USR0152.....................................................
67 VDR Event Messages....................................................................................2156 VDR1................................................................................................................................................ 2156 VDR10..............................................................................................................................................2156 VDR100..........................................................................................
VDR34............................................................................................................................................. 2180 VDR35.............................................................................................................................................. 2181 VDR36..............................................................................................................................................2182 VDR37..................................................
68 VF Event Messages.......................................................................................2207 VF001.............................................................................................................................................. 2207 VF002.............................................................................................................................................. 2207 VF003.........................................................................................
VF040.............................................................................................................................................. 2219 VF041...............................................................................................................................................2219 VF042.............................................................................................................................................. 2219 VF043................................................
VFL0714...........................................................................................................................................2232 VFL0715........................................................................................................................................... 2232 VFL0716...........................................................................................................................................2232 VFL0719...................................................
VLT0209..........................................................................................................................................2253 VLT0210.......................................................................................................................................... 2254 VLT0211...........................................................................................................................................2254 VLT0212.....................................................
VME0002.........................................................................................................................................2278 VME0003.........................................................................................................................................2279 VME0004........................................................................................................................................ 2279 VME0005..........................................................
1 AMP Event Messages AMP0300 Message The system board arg1 current is less than the lower warning threshold. Arguments arg1 = name Detailed Description None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
LCD Message System board current is outside of range. Contact Support Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* AMP0302 Message The system board arg1 current is greater than the upper warning threshold.
Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded. Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes. Category System Health (AMP = Amperage) Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message System board current is outside of range.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* AMP0305 Message The system board arg1 current is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* AMP0307 Message Disk drive bay arg1 current is less than the lower critical threshold.
Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
AMP0310 Message Disk drive bay arg1 current is outside of range. Arguments arg1 = name Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded. Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* AMP0312 Message System level current is less than the lower warning threshold. Detailed Description None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
Trap/EventID 2177 LCD Message System level current is outside of range. Contact Support iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC AMP0314 Message System level current is greater than the upper warning threshold. Detailed Description Product documentation contains information on correct configuration.
Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes. Category System Health (AMP = Amperage) Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message System level current is outside of range.
AMP0317 Message System level current is within range. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* AMP0319 Message Chassis power level current is less than the lower critical threshold.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* AMP0321 Message Chassis power level current is greater than the upper critical threshold. Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling.
Severity Severity 1 (Critical) Trap/EventID 2177 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* AMP0323 Message Chassis power level current is within range. Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
AMP402 Message The arg1 sensor returned to a normal state with a value of arg2 A. Arguments arg1 = sensor name, arg2 = current Detailed Description The current sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC AMP404 Message The arg1 sensor detected an error with a value of arg2 A. Arguments arg1 = sensor name, arg2 = current Detailed Description The current sensor identified in the message is faulty or the current drawn by the system exceed the critical threshold.
Detailed Description The current sensor identified in the message may be faulty. This condition can cause system performance issues and degradation in the monitoring capability of the system. Recommended Response Action Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a faulty sensor, replace the system board. For more information, contact your service provider.
2 ASR Event Messages ASR0000 Message The watchdog timer expired. Detailed Description The operating system or potentially an application failed to communicate to the baseboard management controller (BMC) within the timeout period. Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC ASR0002 Message The watchdog timer powered off the system. Detailed Description The operating system or an application failed to communicate to the baseboard management controller (BMC). The system powered off per the configured setting.
Severity Severity 1 (Critical) Trap/EventID 2233 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC ASR0008 Message The watchdog timer interrupt was initiated. Detailed Description The operating system or an application failed to communicate to the baseboard management controller (BMC) within the timeout period.
Recommended Response Action No response action is required. Category System Health (ASR = Auto Sys Reset) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC ASR0100 Message The BIOS watchdog timer reset the system.
Detailed Description The operating system or an application failed to communicate within the timeout period. System was reset. (IPMI sensor type code 23h offset 01 - event 3:0 - 3h if booting 4h if running) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
ASR0103 Message The OS watchdog timer powered down the system. Detailed Description The operating system or an application failed to communicate within the timeout period. The system was powered down. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC ASR0105 Message The OS watchdog timer powered off the system. Detailed Description The operating system or an application failed to failed to communicate within the timeout period. The system was powered off. (IPMI sensor type code 23h offset 02h event 3:0 - 4h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC ASR0107 Message The OS watchdog timer pre-timeout interrupt was initiated. Detailed Description The operating system or an application failed to respond to a pre-notification within the timeout period.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC ASR200 Message The watchdog timer expired at arg1 . Arguments arg1 = day month date hh:mm:ss yyyy Detailed Description The watchdog timer has expired at the date and time identified in the message, because iDRAC did not receive a response within the specified time.
Recommended Response Action To determine the correct cause of the exception, contact your service provider Category System Health (ASR = Auto Sys Reset) Severity Severity 1 (Critical) OMSA Event ID 5006 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC ASR202 Message The watchdog timer turned off the system at arg1 .
ASR203 Message The watchdog timer performed an AC power cycle on the system at arg1 . Arguments arg1 = day month date hh:mm:ss yyyy Detailed Description The watchdog timer has performed an AC power cycle on the system after the specified time at the date and time identified in the message, because the operating system has crashed or hung.
LC Log iDRAC ✔* CMC ✔* 142 LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔*
3 BAR Event Messages BAR001 Message Export System Profile requested. Detailed Description A system profile export operation has been requested. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR003 Message Preparing vFlash Backup partition. Detailed Description The Backup partition is being created for storing the backup file. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR005 Message Collecting Lifecycle Controller data. Detailed Description The Lifecycle Controller data is being collected and copied into the backup file. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR007 Message Export System Profile completed. Detailed Description System profile export operation is successfully completed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR009 Message Valid vFlash media not present. Detailed Description The vFlash media is not present on the system. Recommended Response Action Insert the appropriate vFlash media in the designated vFlash portal, enable and initialize it, and retry.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR011 Message Unable to collect Hardware Inventory information. Detailed Description Hardware Inventory data collection and export did not complete successfully. Recommended Response Action Enter system services to enter Unified Server Configurator (USC), and select exit and reboot option in USC to instantiate the database, if Collect System Inventory on Restart (CSIOR) is not enabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR013 Message Host System Shutdown unsuccessful. Detailed Description The request to shut the Host system down did not complete successfully. Recommended Response Action Restart the Integrated Remote Access Controller (iDRAC) and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR015 Message Backup file data processing error. Detailed Description The Backup file information was not properly processed and the operation cannot continue. This can be due to resource constraints within the processing environment. If the network share is read only, this error will be thrown also.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR017 Message Backup file validation requested. Detailed Description A system profile backup file validation has been requested. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR019 Message Validating Restore operation, allow several minutes for this to complete. Detailed Description A system profile backup file validation is in progress. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR021 Message Insufficient space on network share. Detailed Description The system profile export could not complete successfully as there is insufficient space on the network share or connectivity was lost.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR023 Message Starting component updates. Detailed Description The process is entering the component update phase of the restore operation. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR025 Message Restoring Component Firmware. Detailed Description For each component with firmware, an update is in progress. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR027 Message Host System Component Restore complete, shutting down Host System. Detailed Description The component restoration on the host system is complete. The Host System will shutdown. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR029 Message Restoring Integrated Remote Access Controller firmware. Detailed Description The Integrated Remote Access Controller firmware and configuration import is in progress. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR031 Message RESERVED Detailed Description RESERVED Recommended Response Action RESERVED Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR033 Message Unable to Restore Lifecycle Controller data. Detailed Description A Lifecycle Controller internal data import operation did not complete successfully. Recommended Response Action Do the following: 1) Download and apply the Dell Update Package for the Unified Server Configurator (USC).
Category Configuration (BAR = Backup/Restore) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR035 Message Unable to Restore Integrated Remote Access Controller configuration. Detailed Description The Integrated Remote Access Controller (iDRAC) Configuration import did not complete successfully.
Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR037 Message System Reset or Lifecycle Controller Actions Canceled, System Profile Failure Recovery completed. Detailed Description Adjustments to Lifecycle and Integrated Remote Access Controller environments are complete.
Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR039 Message License not present. Detailed Description The license required for operation is not present. Recommended Response Action Use supported vFlash media and licensing for this feature, and try the operation again.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR041 Message System Shutdown. Detailed Description Shutting down host system. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR043 Message Timeout waiting for Unified Server Configurator to exit. Detailed Description A timeout occurred waiting for the Unified Server Configurator (USC) to exit. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR045 Message Powering down the Host System for Integrated Remote Access Controller Restore. Detailed Description The host system is powering down to facilitate the import of the Integrated Remote Access Controller system profile. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR047 Message System Profile operation canceled by user. Detailed Description The System Profile operation was canceled as part of a clean up operation performed during a restart of the Integrated Remote Access Controller. Recommended Response Action Resubmit the System Profile operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR049 Message Automatic Host System power up setup failed. Detailed Description The automatic Host System power up request has erred and the system will not power up after the Integrated Remote Access Controller has restarted. Recommended Response Action As indicated by the job status, wait for restore to complete.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR051 Message Performing Component Configuration Restore for Device : arg1 Arguments arg1 = device name Detailed Description The configuration import for the specified device is in progress. Recommended Response Action No response action is required.
device indicated will update the firmware storage partition. A backup of the server profile is recommended after updating. Recommended Response Action No response action is required.
BAR054 Message System Reset or Lifecycle Controller Actions Canceled, System Profile Failure Recovery unsuccessful. Detailed Description The attempt to clean up after an unsuccessful Backup/Restore of a system profile operation has not been successful. The Lifecycle Controller/System Services related operations may not execute as expected until the system is properly restored to a functional configuration. Recommended Response Action Enter the iDRAC configuration utility.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR056 Message Component Configuration Restored on Device : arg1 Arguments arg1 = device name Detailed Description The configuration import was successful for the specified device. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR058 Message Validating NFS destination access. Detailed Description The system profile import or export network destination is being tested for access. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR060 Message Collecting firmware inventory information. Detailed Description Collecting firmware inventory and copying it into the system profile backup file. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR062 Message Collecting Lifecycle Controller Configuration database. Detailed Description Collecting the Lifecycle Controller configuration database and copying it into the server profile backup file. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR064 Message Collecting Integrated Remote Access Controller firmware. Detailed Description Collecting the Integrated Remote Access Controller firmware and copying it in the server profile backup file. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR066 Message vFlash media not enabled. Detailed Description The system profile export destination is not enabled. Recommended Response Action Enable the vFlash media and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR068 Message vFlash media not supported. Detailed Description The system profile export destination is not supported. Recommended Response Action Insert, enable and initialize supported vFlash media and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR070 Message NFS Destination access denied. Detailed Description Access to the NFS export/import destination is not possible or has been denied. Recommended Response Action Verify that the input parameters are correct, connectivity exists to the destination end point, and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR072 Message Format of vFlash Backup partition unsuccessful. Detailed Description The vFlash backup partition format operation was not successful. Recommended Response Action Enable and initialize the vFlash media and retry the export. If the issue persists, try a new vFlash media or use the network share option(s).
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR074 Message Unable to collect Firmware Inventory information. Detailed Description The collection and export of firmware inventory data did not complete successfully. Recommended Response Action Apply the Dell Update Package for Unified Server Configurator (USC).
Category Configuration (BAR = Backup/Restore) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR076 Message Unable to collect the Configuration database. Detailed Description The collection and export of Lifecycle Controller Configuration Database failed.
Recommended Response Action Apply Dell Update Packages for all devices and software, and try the operation again. If the error continues, repair the Lifecycle Controller and apply the packages again, and retry the operation.
Recommended Response Action Apply the integrated remote access controller firmware, manually set the configuration attributes, and try the operation again. Category Configuration (BAR = Backup/Restore) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR080 Message Restoring Lifecycle Controller Configuration database.
Recommended Response Action No response action is required. Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR082 Message Restoring Remote Access Controller configuration. Detailed Description Remote access controller firmware and configuration import in progress.
Recommended Response Action Obtain a valid host system backup image and try the operation again. Reboot the remote access controller and try the operation again. If the error continues, download a new remote access controller firmware image and try the operation again.
Detailed Description The validation of the system profile backup file has failed. The retrieval of system information to validate the backup file has failed. Recommended Response Action Restart the remote access controller, and retry the operation. If the error continues, use the remote access controller firmware to try the operation again.
BAR087 Message Unable to Restore the Lifecycle Controller Firmware images. Detailed Description The system profile import of Lifecycle Controller firmware images has failed. Recommended Response Action Apply the Dell Update Package for this system. If the error continues, use the field service repair software to repair the Lifecycle Controller.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR089 Message Lifecycle Controller needs to be updated. Detailed Description A problem has been detected with the installation of the Unified Server Configurator (USC). This needs to be corrected before a valid Backup file can be created. Recommended Response Action Obtain the Dell update package for the Unified Server Configurator and apply it. Then perform a Backup operation to save this data, for later restore.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR091 Message System Profile Backup completed. Detailed Description A System Profile Backup request made by the user of the Unified Server Configurator interface has completed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR093 Message Disconnect from CIFS unsuccessful. Detailed Description The attempt to disconnect from the specified CIFS location was not successful. Recommended Response Action If this happens on a backup request, restart the Integrated Remote Access Controller and try the operation again. If this is a restore request the Integrated Remote Access will be restarted during the execution of the request.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR095 Message Another Restore operation already in progress. Detailed Description The request to restore a System Profile from a Backup file did not complete successfully because there is already a request in progress.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR097 Message Lifecycle Controller Unified Server Configurator incompatibility detected. Detailed Description The current Lifecycle Controller Unified Server Configurator software installed on the system does not have Backup and Restore feature support.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR099 Message Collecting License data. Detailed Description License data is being collected and copied into the backup Server Profile. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR101 Message Restoring License data. Detailed Description Importing license data from the backup Server Profile. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR103 Message Collecting system branding data. Detailed Description System branding data is being collected and copied to the backup Server Profile. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR105 Message Restoring system branding data. Detailed Description Importing system branding data from the Server Profile backup file. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR107 Message vFlash media reader license not present. Detailed Description The vFlash media reader requires a license to function. Recommended Response Action Obtain the license for vFlash media from your service provider. Install the license and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR109 Message OEMDRV partition is in use. Detailed Description The OEMDRV partition is mounted for performing operating system deployment use. This situation prevents the Export and Import Server Profile operation from continuing.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR111 Message Server Profile operation timed out. Detailed Description The Import or Export job did not complete successfully. The Import or Export operation timed-out while validating or transferring Server Profile data.
Recommended Response Action Obtain a valid Server Profile file for the target system and try the operation again. If the problem reoccurs, restart the iDRAC and try the operation again.
Arguments arg1 = job ID Detailed Description The Automatic Backup job identified in the message is created per the Server Profile automatic export schedule previously configured. Recommended Response Action No response action is required.
BAR116 Message Unable to create a recurring export Server Profile job because an existing scheduled Backup Image job is scheduled within the next 24 hours. Detailed Description Unable to create a recurring export Server Profile job because an existing scheduled Backup Image job is scheduled within the next 24 hours. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy 203
4 BAT Event Messages BAT0000 Message The system board battery is low. Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the system board battery at the next service window.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* BAT0002 Message The system board battery has failed. Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the system board battery.
Recommended Response Action No response action is required. Category System Health (BAT = Battery Event) Severity Severity 3 (Informational) Trap/EventID 2227 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* BAT0004 Message The system board battery is absent.
BAT0005 Message The storage battery is low. Detailed Description The system has to remain powered on to charge the battery. Recommended Response Action Allow the PERC RAID controller battery to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC BAT0007 Message The storage battery has failed. Detailed Description The PERC RAID controller battery may have failed because of thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation. 2) Check the system logs for thermal related issues.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC BAT0009 Message The storage battery is absent. Detailed Description The PERC RAID controller battery may report absent due to disconnect or thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation.
Recommended Response Action Allow the PERC RAID controller battery for the associated bay to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
BAT0012 Message The storage battery for disk drive bay arg1 has failed. Arguments arg1 = bay Detailed Description The PERC RAID controller battery may have failed because of thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation for the associated bay. 2) Check the system logs for thermal related issues.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC BAT0014 Message The storage battery for disk drive bay arg1 is absent. Arguments arg1 = bay Detailed Description The PERC RAID controller battery may report absent due to disconnect or thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation for the associated bay. 2) If installed, reseat or reconnect the battery and cables.
Trap/EventID iDRAC 2226 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC BAT0016 Message The arg1 battery is operating normally. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Check the battery. Category System Health (BAT = Battery Event) Severity Severity 1 (Critical) Trap/EventID 2225 LCD Message The battery has failed. Check battery. iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC BAT0018 Message The arg1 battery is present.
BAT0019 Message The arg1 battery is absent. Arguments arg1 = name Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery to confirm presence. Category System Health (BAT = Battery Event) Severity Severity 1 (Critical) Trap/EventID 2225 LCD Message The battery is absent. Check battery.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAT0031 Message The system board battery status is unknown. Detailed Description The system battery level is unknown, and if the input power is disconnected, the system settings will not be preserved. Recommended Response Action Replace the battery.
OMSA Event ID 2264 OMSA Trap ID 75300;80300;85300;90300;95300;100300;105300;110300;115300;120300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* BAT1001 Message Battery on arg1 was replaced. Arguments arg1 = controller name Detailed Description A controllers battery was replaced.
Arguments arg1 = controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* BAT1004 Message The battery on arg1 learn cycle has timed out. Arguments arg1 = controller name Detailed Description The controller battery must be fully charged before the learn cycle can begin. The battery may be unable to maintain a full charge causing the learn cycle to timeout. In addition, the battery must be able to maintain cached data for a specified period of time in the event of a power loss.
Recommended Response Action No response action is required. Category Storage (BAT = Battery Event) Severity Severity 3 (Informational) Trap/EventID 4275 OMSA Event ID 2179 OMSA Trap ID 115100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔* BAT1006 Message The battery on arg1 learn cycle will start in arg2 days.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* BAT1007 Message The battery on arg1 learn cycle will start in arg2 hours. Arguments arg1 = Controller name, arg2 = arg Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 4274 OMSA Event ID 2188 OMSA Trap ID 115300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* BAT1009 Message Write policy on arg1 was changed to Write Back. Arguments arg1 = controller name Detailed Description The controller battery health has returned to normal.
BAT1010 Message Battery on arg1 requires reconditioning. Initiate a learn cycle. Arguments arg1 = Controller name Detailed Description Battery is in warn only mode and requires reconditioning. Recommended Response Action Start a learn cycle on the battery.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔* BAT1012 Message The arg1 battery temperature is above normal. Arguments arg1 = Controller name Detailed Description Diagnostic event for service to determine if there is an ambient temperature problem. Recommended Response Action No response action is required.
Category Storage (BAT = Battery Event) Severity Severity 2 (Warning) Trap/EventID 4274 OMSA Event ID 2213 OMSA Trap ID 115300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔* BAT1014 Message arg1 battery charge in-progress.
BAT1015 Message arg1 battery charge process is interrupted. Arguments arg1 = Controller name Detailed Description Diagnostic event for service to determine if there is an ambient temperature problem. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ BAT1017 Message The arg1 battery learn mode has changed to Warn. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action If the battery is being charged, then charging the battery should be stopped until the battery cools down and charging should be resumed. If this is not case, then some other condition exists and should be investigated.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ BAT1020 Message The arg1 battery is executing a learn cycle. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Trap/EventID 4274 OMSA Event ID 2278 OMSA Trap ID 115300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ BAT1022 Message arg1 battery recondition is completed. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes.
BAT1023 Message The charge level for the battery on arg1 is within normal limits. Arguments arg1 = controller name Detailed Description The battery health has returned to normal. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ BAT1025 Message arg1 is unable to recover cached data from the Battery Backup Unit (BBU). Arguments arg1 = controller name Detailed Description The controller was unable to recover data from the cache. This may indicate data loss has occurred.
Arguments arg1 = controller name Detailed Description The controller has retrieved cached data. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ BAT1028 Message The battery voltage on arg1 is low. Arguments arg1 = controller name Detailed Description The controller battery voltage is low. This may indicate that the battery is no longer protecting the controller cache. Recommended Response Action The battery needs to recharged. Wait 24 hours to see if the charge is restored.
Trap/EventID 4273 OMSA Event ID 2169 OMSA Trap ID 115400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ BAT1030 Message The arg1 battery charge level is normal. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes.
BAT1031 Message The battery temperature on arg1 is above normal. Arguments arg1 = controller name Detailed Description The room temperature may be too hot. In addition, the system fan may be degraded or failed. Recommended Response Action Verify that the room temperature is normal and that fans are functioning properly. See the storage hardware documentation for acceptable operating temperatures.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ BAT1033 Message The battery on arg1 was removed. Arguments arg1 = controller name Detailed Description The controller cannot communicate with the battery. Either the battery was removed, or the contact point between the controller and the battery is degraded.
Arguments arg1 = controller name Detailed Description One or more battery properties were modified. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC BAT1036 Message The battery on arg1 is discharging. Arguments arg1 = controller name Detailed Description The battery on the controller identified in the message is being discharged. Recommended Response Action No response action is required.
5 BIOS Event Messages BIOS001 Message The command was successful Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration (BIOS = BIOS Management) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS002 Message Resource allocation failure.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BIOS003 Message Missing required parameter. Refer to the inserted comment. Detailed Description An invalid number of arguments was passed to the method. Recommended Response Action Enter all the required command parameters. Check documentation and try again.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BIOS005 Message Mismatch in AttributeName and AttributeValue count Detailed Description The number of AttributeName and AttributeValue parameters do not match. Recommended Response Action Enter the same number of parameters for AttributeName and AttributeValue. Refer to documentation for method input parameter details.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BIOS007 Message Configuration job already created, cannot create another configuration job on specified target until existing job is completed or is cancelled Detailed Description A configuration job is already created on the specified target. No further command is allowed until the existing job succeeds or the job is cancelled. Recommended Response Action Wait for the job to complete.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BIOS009 Message Lifecycle Controller is currently in use. Detailed Description Lifecycle Controller cannot gain access to internal storage because of use by another application or operation. Recommended Response Action Wait for the current Lifecycle Controller operation to complete.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS011 Message Configuration job already created, pending data cannot be deleted Detailed Description Configuration job already created on the specified target. No further command is allowed until the existing job is completed.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS013 Message Invalid AttributeName arg1 Arguments arg1 = attribute name Detailed Description An unknown AttributeName was specified in the operation. Recommended Response Action Enter the correct AttributeName available in the system. Refer to the enumeration response for desired attribute.
Category Configuration (BIOS = BIOS Management) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS015 Message AttributeValue cannot be changed to read only AttributeName arg1 . Arguments arg1 = attribute name Detailed Description A set attribute operation was attempted on a read only attribute.
Recommended Response Action No response action is required. Category Configuration (BIOS = BIOS Management) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS017 Message Unable to delete vFlash pending one-time boot configuration Detailed Description Unable to delete vFlash pending one-time boot configuration.
Recommended Response Action Retry the operation with a BIOS password that conforms with system BIOS password requirements. Category Configuration (BIOS = BIOS Management) Severity Severity 2 (Warning) No alerts are applicable for this message BIOS021 Message Cannot authenticate BIOS password. Detailed Description The old BIOS password specified in the change BIOS password operation was incorrect. Recommended Response Action Retry the operation with correct old BIOS password.
No alerts are applicable for this message BIOS024 Message The set operation did not complete successfully as the attribute is read-only. Detailed Description The operation cannot run as the attribute value cannot be modified. Recommended Response Action For more information on the attribute, see Lifecycle Controller-Remote Services documentation.
BIOS027 Message Unable to change the BIOS password because the password is currently being configured using plain text. Unable to set the attribute arg1 . Arguments arg1 = attribute name Detailed Description The attribute identified in the message cannot be set, because the password is currently being reset by using plain text. The BIOS password cannot be simultaneously configured by using plain text and a hash.
Detailed Description The BIOS password cannot be configured because an Export Server Profile operation is already running. Recommended Response Action Wait until the current export operation is completed, and then retry the operation. Category Configuration (BIOS = BIOS Management) Severity Severity 2 (Warning) No alerts are applicable for this message BIOS030 Message Unable to change the BIOS password because an Import Server Profile operation is already running.
BIOS102 Message A system BIOS update is scheduled that requires a reboot. Detailed Description A BIOS update job is scheduled through the remote access controller, and the system must be rebooted to apply the update. Recommended Response Action Reboot the system to apply the BIOS update.
LC Log iDRAC CMC 254 ✔ LCD OS Log ✔* Power Off Power Cycle Reset Chassis Event Proxy
BOOT Event Messages 6 BOOT001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
BOOT004 Message Invalid number of Boot Source arguments Detailed Description An invalid number of source arguments was passed to the method. Recommended Response Action Check documentation and try again (details) Category Configuration (BOOT = BOOT Control) Severity Severity 3 (Informational) No alerts are applicable for this message BOOT005 Message Missing required parameter. Detailed Description One or more of the invoked methods required parameters are missing.
Detailed Description One or more of the Boot Source instance IDs does not belong to the affected Boot Configuration. Recommended Response Action ChangeBootOrderByInstanceID only accepts Boot Sources from the impacted Boot Configuration. Verify that all source arguments belong to the desired Boot Configuration.
Category Configuration (BOOT = BOOT Control) Severity Severity 3 (Informational) No alerts are applicable for this message BOOT011 Message Failed to set vFlash partition for one time boot Detailed Description The provided vFlash partition could not be set for one time boot. Recommended Response Action Power cycle system and reapply firmware packages for Lifecycle Controller and iDRAC.
BOOT014 Message Virtual media not ready. Detailed Description The systems SD card has been removed or is in use. Recommended Response Action Verify that the SD card is inserted and that another operation is not in progress, and try again. Category Configuration (BOOT = BOOT Control) Severity Severity 3 (Informational) No alerts are applicable for this message BOOT015 Message Set operation successful for the boot partition.
BOOT017 Message Source argument does not support enable or disable mode. Detailed Description The boot device(s) specified in the source argument used in the operation cannot be enabled or disabled. This behavior applies to BCV devices and one-time boot. Recommended Response Action Refer to the documentation on validity of operation for the boot device specified. For more information on the operation, see Lifecycle Controller-Remote Services documentation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* 261
7 CBL Event Messages CBL0001 Message Backplane arg1 power cable disconnected. Arguments arg1 = bay ID Detailed Description A backplane signal cable was detected, but the accompanying power cable was not present. Recommended Response Action Reconnect or replace the power cable. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle ✔* ✔ WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy CMC CBL0003 Message Backplane arg1 arg2 cable is disconnected. Arguments arg1 = bay ID, arg2 = cable name Detailed Description The backplane cable identified in the message is disconnected or no cable is detected. Recommended Response Action Reconnect or replace the cable identified in the message.
Category System Health (CBL = Cable) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle ✔* ✔ WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy CMC CBL0005 Message Backplane arg1 arg2 connector incorrectly connected to the motherboard SATA controller.
Detailed Description Each server model only supports a certain set of backplane configurations. For unified backplanes or split mode capable backplanes that are in unified mode, multiple controllers cannot be connected to the same backplane. In unified backplane situations any controller besides the first will not be operational. Recommended Response Action Make sure that only one RAID controller is connected to the backplane. If the issue persists, contact your service provider.
CBL0008 Message One or more cables are missing from arg1 . Arguments arg1 = controller name Detailed Description One or more cables have been detected as missing from the Fault Tolerant storage controller identified in the message. Recommended Response Action Make sure all cables are properly connected. For information about cabling, see the Owners Manual available at the support site.
Detailed Description The SAS cable identified in the message is not connected to the correct expander. Recommended Response Action Reconnect the SAS cable to the correct expander and retry the operation.
CMC Event Messages 8 CMC001 Message The operation is successfully completed. Detailed Description The operation is successfully completed. Recommended Response Action No response action is required. Category Configuration (CMC = Chassis Management Controller) Severity Severity 3 (Informational) No alerts are applicable for this message CMC002 Message Unable to complete the operation because of an unknown issue.
No alerts are applicable for this message CMC004 Message Unable to complete the operation because the parameter arg1 is invalid. Arguments arg1 = parameter name Detailed Description The operation cannot be completed because the parameter identified in the message is invalid. Recommended Response Action Enter a valid parameter and retry the operation. For information about valid parameters, see the CMC Profile document available on the support site.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC CMC8501 Message Chassis Group Leader has synchronized this members configuration. Detailed Description Multi Chassis Management feature on CMC allows for pushing the lead chassis configuration data to its members.
Category System Health (CMC = Chassis Management Controller) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8503 Message Unable to access the IPv4 information of the server. Detailed Description CMC is unable to access the IPv4 information for the specified server.
Recommended Response Action Enable the NIC on the server identified in the message using the CMC command line or CMC Web interface, so that the link to launch iDRAC is displayed on the CMC Web interface. To enable the NIC for DHCP using RACADM, enter "racadm setniccfg -m server- -d" where is the server identified in the message. To enable the NIC using the Web interface, click Server Overview > select the identified server, go to Setup > select the Enable LAN check box.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC8506 Message A command to shut down the CMC was initiated. Detailed Description A command to shut down the CMC was initiated. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8508 Message Unable to synchronize the primary and secondary CMC removable flash media and the Extended Storage feature is not available.
Detailed Description The extended storage feature is not activated if the media on the secondary CMC is no longer functional. Recommended Response Action Do one of the following, and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration and verify if the card on the secondary CMC displays errors. 2) Do a failover and then reprovision the card from the same GUI page. Reprovisioning is only allowed on the card of primary CMC.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8511 Message Unable to synchronize the data in the Extended Storage removable flash media in the primary and secondary CMCs.
Recommended Response Action Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If errors are displayed, execute the following racadm command: "racadm cmcchangeover". 3) Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media > Configuration > Repair Active Controller Media in the CMC Web interface.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* CMC8514 Message Fabric mismatch is detected in the I/O Module arg1 . Arguments arg1 = iom slot name Detailed Description This error may occur due to any of the following conditions: 1) Invalid I/O Module and mezzanine card configuration, where a newly installed I/O Modules fabric type and the resident mezzanine cards fabric types do not match or are incompatible.
Severity Severity 2 (Warning) Trap/EventID 2546 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8517 Message A double height server is detected in slot arg1 , however the server is not detected in the bottom slot.
Arguments arg1 = slot number, arg2 = slot number Detailed Description the Double height server identified in the message is detected in the top slot. However, the bottom slot is also responding which should not occur if a double height server is inserted. Recommended Response Action Do the following: 1) Remove the server identified in the message. 2) Restart the CMC and wait for the CMC to complete the start up process. 3) Reinsert the server identified in the message.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* CMC8520 Message The FRU on server arg1 is not functioning. Arguments arg1 = slot number Detailed Description FRU on the server specified in the message is not functioning or CMC is unable to read it. Recommended Response Action Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8522 Message The Mezz card 2 FRU for the server arg1 is not functioning. Arguments arg1 = slot number Detailed Description The Mezz card 2 FRU for the server specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
CMC8525 Message The FRU on the sleeve arg1 is not functioning. Arguments arg1 = slot number Detailed Description The FRU on the sleeve specified in the message is not functioning or CMC is unable to read it. Recommended Response Action Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* CMC8527 Message Unable to retrieve the server- arg1 memory information. Arguments arg1 = slot number Detailed Description CMC is unable to obtain the memory information from the server specified in the message. This occurs if there is no communication between CMC and iDRAC. Recommended Response Action Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8529 Message Unable to perform the requested action on the server- arg1 , because of insufficient privileges. Arguments arg1 = slot number Detailed Description The user account does not have sufficient privileges to perform the requested operation.
privilege is required to perform a virtual reseat operation. This applies to Sleeve or Sled components. Recommended Response Action Use a different user account that has server administration privileges, and retry the operation. For more information, contact your system administrator about necessary privileges.
CMC8533 Message Unable to read the FRU information, status = arg1 Arguments arg1 = status value Detailed Description Unable to read the header of the extended FRU information. This can occur if there is a problem in the communication between the CMC and the server. Recommended Response Action Remove and reinsert the server. The CMC will retry the read operation of the FRU information. If the issue persists, contact your service provider.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* CMC8535 Message Unable to turn on High Power Management for the server arg1 Arguments arg1 = slot number Detailed Description Unable to turn on the server specified in the message because of an internal CMC error. Recommended Response Action Reboot CMC and retry the operation. If the issue persists, reseat the server and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8539 Message The CMC arg1 is unable to log arg2 event to the Hardware Log. Arguments arg1 = slot id, arg2 = event message Detailed Description CMC cannot log new events to Hardware Log if Hardware Log is full. Therefore, new events are not written to the log unless older events are cleared.
Category Audit (CMC = Chassis Management Controller) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8541 Message The watchdog has reset the CMC arg1 . Arguments arg1 = slot id Detailed Description The CMC specified in the message was reset by a watchdog event.
Recommended Response Action No response action is required. Category Audit (CMC = Chassis Management Controller) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8543 Message The CMC arg1 has reset because the thermal threshold was exceeded.
CMC8545 Message Detected a missing process failover condition detected. Process = arg1 . Arguments arg1 = process name Detailed Description A firmware error has occurred causing a CMC failover. The process identified in the message was not detected. The CMC will restart automatically. Recommended Response Action No response action is required. If multiple failovers occur, contact your service provider.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC8547 Message Missing kernel module arg1 . Failover condition detected Arguments arg1 = module name Detailed Description A firmware error occurred causing the failover. If this condition continues, a failover will result. If multiple failovers occur, contact Service. Recommended Response Action No response action is required. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8550 Message The chassis health is arg1 . Arguments arg1 = health state Detailed Description If the chassis health status changes, new status is logged. The possible states are Invalid, Other, Unknown, Healthy, Non-critical, Critical, and Non-recoverable.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8553 Message An internal error occurred and a failover condition is detected. Detailed Description An internal I2C hardware occurred and CMC initiated a failover to clear the hardware error. If the issue persists, contact your service provider..
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8555 Message An internal memory error has occurred and a failover condition is detected. Detailed Description An internal memory error occurred affecting the configuration database and CMC has initiated a failover . If the issue persists, contact your service provider.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8558 Message The system health is restored. Detailed Description The system health has recovered from a failover condition. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8562 Message The log is cleared. Detailed Description The hardware log is cleared. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8564 Message The KVM mapping feature is disabled. Detailed Description The KVM is not mapped to any of the server slots. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8566 Message KVM mapping is disabled for the server slot arg1 . Arguments arg1 = slot number Detailed Description The KVM mapping is disabled for the server slot specified in the message. The KVM cannot be mapped to this server slot.
Category Audit (CMC = Chassis Management Controller) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8568 Message The DVD drive mapping feature is disabled. Detailed Description The DVD drive is disabled and is not mapped to any of the server slots. Recommended Response Action No response action is required.
Category Audit (CMC = Chassis Management Controller) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8570 Message The server slot arg1 is disabled for DVD drive mapping. Arguments arg1 = slot number Detailed Description The server slot specified in the message is disabled for DVD drive mapping.
Category Audit (CMC = Chassis Management Controller) Severity Severity 1 (Critical) Trap/EventID 8689 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8572 Message The coin cell battery in CMC arg1 is not working.
Detailed Description The chassis health is critical or non-recoverable. Recommended Response Action Review the Chassis log or the Chassis Management Controller(CMC) SEL log for the failure or Export chassis log and SEL log and contact technical support . Category Audit (CMC = Chassis Management Controller) Severity Severity 1 (Critical) No alerts are applicable for this message CMC8575 Message The RAC SSL Certificate is changed. Detailed Description The RAC SSL Certificate is changed.
Filter Visibility iDRAC IPMI Alert ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔* ✔* ✔* ✔* ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* CMC8577 Message The Remote Access Controller (RAC) Kerberos Keytab is changed. Detailed Description The Remote Access Controller (RAC) Kerberos Keytab is changed. Recommended Response Action No response action is required.
Trap/EventID Filter Visibility iDRAC 8691 IPMI Alert ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔* ✔* ✔* ✔* ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC8579 Message Unable to upload the security certificate because of an Unexpected Event issue in the Remote Access Controller (RAC).
Recommended Response Action No response action required. Category Configuration (CMC = Chassis Management Controller) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8602 Message The Chassis group arg1 is deleted.
Detailed Description CMC cannot read the information about the FRU, because of an internal issue with the CMC and the server. Some information such as model number may not be reported. The server may not power up if the server planar FRU cannot be read. Recommended Response Action Remove and reinsert the server. The Chassis Management Controller will retry the read operation of the FRU information. If the issue persists, contact your service provider.
CMC8605 Message The chassis health state is no longer OK and is currently arg1 . Arguments arg1 = health state Detailed Description The chassis health state is no longer OK and is currently the state identified in the message. Actions should be taken to resolve any outstanding issues so that the chassis health state will return to OK.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC 311
9 CPU Event Messages CPU0000 Message CPU arg1 has an internal error (IERR). Arguments arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Recommended Response Action Review logs for fan failures, replace failed fans. If no fan failures are detected, check inlet temperature (if available) and reinstall processor heatsink. Category System Health (CPU = Processor) Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU has a thermal trip.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC CPU0003 Message CPU arg1 is stuck in POST. Arguments arg1 = number Detailed Description None Recommended Response Action 1) Turn off the server and disconnect input power for one minute. Re-apply input power and turn system on. 2) Reduce system configuration to minimum memory and remove all PCI devices. If system completes POST, update system BIOS.
Category System Health (CPU = Processor) Severity Severity 1 (Critical) Trap/EventID 2241 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC CPU0005 Message CPU arg1 configuration is unsupported. Arguments arg1 = number Detailed Description System is unable to boot or may run in a degraded state.
CPU0006 Message Unrecoverable CPU complex error detected on CPU arg1 . Arguments arg1 = number Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC CPU0008 Message CPU arg1 is disabled. Arguments arg1 = number Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action if unexpected, check presence, and system setup (BIOS) configuration.
Recommended Response Action No response action is required. Category System Health (CPU = Processor) Severity Severity 3 (Informational) Trap/EventID 2243 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC CPU0010 Message CPU arg1 is throttled.
CPU0011 Message Uncorrectable Machine Check Exception detected on CPU arg1 . Arguments arg1 = number Detailed Description None. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (CPU = Processor) Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message Uncorrectable Machine Check Exception detected on CPU .
OMSA Trap ID iDRAC 5603 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC CPU0016 Message CPU arg1 is operating correctly. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (CPU = Processor) Severity Severity 3 (Informational) Trap/EventID 2243 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC CPU0024 Message CPU arg1 is enabled.
CPU0025 Message CPU arg1 terminator is absent. Arguments arg1 = number Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action Check presence and reinstall the terminator.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC CPU0701 Message CPU arg1 protocol error detected. Arguments arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action 1) Check system and operating system logs for exceptions.
Recommended Response Action Check system and operating system logs for exceptions. If no exceptions found, remove input power, reinstall the processor, then apply input power. Category System Health (CPU = Processor) Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU bus parity error detected.
CPU0704 Message CPU arg1 machine check error detected. Arguments arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action 1) Check system and operating system logs for exceptions. If no exceptions are found continue. 2) Turn system off and remove input power for one minute. Reapply input power and turn system on. 3) Make sure the processor is seated correctly.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CPU0801 Message CPU arg1 voltage regulator module failed. Arguments arg1 = number Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on.
Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CPU0804 Message The power input for CPU arg1 voltage regulator module is outside of range. Arguments arg1 = number Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly.
still persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (CPU = Processor) Severity Severity 2 (Warning) Trap/EventID 2242 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CPU0806 Message CPU arg1 voltage regulator module is incorrectly configure.
CPU0816 Message CPU arg1 voltage regulator module is absent. Arguments arg1 = number Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action if removal was unintended, check presence and re-install . Category System Health (CPU = Processor) Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU voltage regulator module absent.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CPU0819 Message The power input for CPU arg1 voltage regulator module has been restored. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CPU9000 Message An OEM diagnostic event occurred. Detailed Description None Recommended Response Action No response action is required.
10 CPUA Event Messages CPUA0023 Message CPU arg1 is absent Arguments arg1 = number Detailed Description None Recommended Response Action Verify processor installation. If present, reseat the processor. Category System Health (CPUA = Proc Absent) Severity Severity 1 (Critical) Trap/EventID 2457 LCD Message CPU is absent.
11 CTL Event Messages CTL1 Message Controller event log: arg1 Arguments arg1 = message Detailed Description This event is retrieved from the controller when iDRAC storage monitoring was not running. Such events which are generated in the past are logged as informational severity. Recommended Response Action No response action is required.
Trap/EventID 4331 OMSA Event ID 2156 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL100 Message The Patrol Read operation was stopped and did not complete for arg1 .
Detailed Description The controller identified in the message is disabled by a user action. Recommended Response Action No response action is required.
CTL11 Message Configuration on arg1 was reset. Arguments arg1 = controller name Detailed Description A user operation to reset the controller configuration was performed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL13 Message The arg1 cache has been discarded. Arguments arg1 = Controller name Detailed Description The controller has flushed the cache and all data in the cache has been lost.
Detailed Description The storage controller memory identified in the message is not operating correctly. Recommended Response Action Contact your service provider.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL17 Message arg1 arg2 is changed to arg3 . Arguments arg1 = Controller Name, arg2 = propertyname, arg3 = new value Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 75100 IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL19 Message Abort CC on Error, Copyback, and Load Balance has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Detailed Description You have changed the controller rebuild rate. This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ CTL200 Message The current firmware version arg1 is older than the required version arg2 for arg3 . Arguments arg1 = version number, arg2 = version number, arg3 = controller name Detailed Description The firmware on the controller identified in the message is not a supported version. Recommended Response Action Download the supported version from the service provider and install it on the controller.
OMSA Event ID 2132 OMSA Trap ID 75300 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL202 Message Unable to open the firmware and driver configuration file arg1 of arg2 .
CTL203 Message Abort Check Consistency on Error, Copyback or Auto Copyback on Predictive Failure, and Load Balance values are changed for arg1 . Arguments arg1 = controller name Detailed Description The status of the changed attribute values are reported for information purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL205 Message Auto Copyback on Predictive Failure, Abort Check Consistency on Error, and Load Balance values are changed for arg1 . Arguments arg1 = controller name Detailed Description The status of the changed attribute values are reported for information purposes.
Detailed Description The status of the changed attribute values are reported for information purposes. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL208 Message Unable to authenticate the entered passphrase for the arg1 . Arguments arg1 = controller name Detailed Description Unable to authenticate the entered passphrase. Recommended Response Action Enter the correct passphrase and retry.
OMSA Trap ID Filter Visibility 75100 IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL21 Message Abort CC on Error and Load Balance has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Detailed Description The persistent hot spare feature is disabled on the controller identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL212 Message The existing encryption key in the arg1 is deleted. Arguments arg1 = controller name Detailed Description This alert is generated when the encryption key in the controller is deleted. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 75100 IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL214 Message The Local Key Management (LKM) encryption key in the arg1 has changed. Arguments arg1 = controller name Detailed Description The Local Key Management (LKM) encryption key in the controller identified in the message has changed.
Detailed Description The controller identified in the message has two connectors that are connected to the same enclosure. The communication path on one connector has lost connection with the enclosure. The communication path on the other connector is reporting this loss. Recommended Response Action Make sure both the cables are securely attached to the enclosure and controller.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL217 Message Redundant path view is cleared on arg1 . Arguments arg1 = controller name Detailed Description The redundant path view on the controller identified in the message is cleared. Recommended Response Action No response action is required.
OMSA Event ID 2226 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL23 Message Copyback and Auto Copyback on Predictive Failure has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL26 Message Copyback and Abort CC on Error has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Trap/EventID 4331 OMSA Event ID 2232 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ CTL28 Message The Background Initialization (BGI) rate has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes.
CTL29 Message The Patrol Read rate has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ CTL30 Message The Check Consistency rate has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action Re-issue the command. Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2236 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL32 Message Abort CC on Error is modified for arg1 .
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL33 Message The arg1 debug log file has been exported. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Trap/EventID 4331 OMSA Event ID 2239 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL35 Message A foreign configuration was imported on arg1 .
CTL36 Message The Patrol Read mode has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL38 Message The Patrol Read operation completed for arg1 . Arguments arg1 = controller name Detailed Description The patrol read task ended. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2267 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL4 Message arg1 alarm is disabled.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ CTL40 Message Multi-bit ECC error on arg1 DIMM. Arguments arg1 = Controller name Detailed Description An error involving multiple bits has been encountered during a read or write operation. The error correction algorithm recalculates parity data during read and write operations.
Recommended Response Action No response action is required. Category Storage (CTL = Storage Contr) Severity Severity 2 (Warning) Trap/EventID 4330 OMSA Event ID 2290 OMSA Trap ID 75300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL42 Message Enclosure Management Module (EMM) hot plug is not supported on arg1 .
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ CTL43 Message Diagnostic message arg1 from arg2 Arguments arg1 = args, arg2 = Controller name Detailed Description This alert is provided for informational purposes. The text for this alert is generated by the utility that ran the diagnostics and can vary depending on the situation. Recommended Response Action No response action is required.
Trap/EventID 4329 OMSA Event ID 2316 OMSA Trap ID 75400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL45 Message Single-bit ECC error on arg1 . Arguments arg1 = Controller name Detailed Description The Dual In-line Memory Module (DIMM) is beginning to malfunction.
CTL46 Message Single-bit ECC error. The arg1 DIMM is critically degraded. Arguments arg1 = Controller name Detailed Description The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may occur.. Recommended Response Action Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a part of the controller battery pack. Refer to the storage hardware documentation for information on replacing the DIMM.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL48 Message A foreign configuration was detected on arg1 . Arguments arg1 = controller name Detailed Description The controller has physical disks that were moved from another controller or have been removed and replaced on the current configuration.
Arguments arg1 = Controller name Detailed Description The NVRAM has corrupted data. This may occur after a power surge, a battery failure, or for other reasons. The controller is reinitializing the NVRAM. Recommended Response Action No response action is required as the controller is taking the required corrective action. However, If this message is generated often (such as during each reboot), then replace the controller.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ CTL50 Message The arg1 NVRAM has corrupt data. Arguments arg1 = Controller name Detailed Description The NVRAM has corrupt data. The controller is unable to correct the situation. Recommended Response Action Replace the controller.
Recommended Response Action Make sure the SAS cables attached to the enclosure/backplane are attached securely. Refer to the storage hardware documentation for more information on checking the cables. Contact technical support if the issue persists.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ CTL53 Message A controller hot plug has been detected. Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Event ID 2266;2334 OMSA Trap ID 75100;80100;85100;90100;95100;100100;105100;110100;115100;120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL55 Message arg1 event log: arg2 Arguments arg1 = Controller name, arg2 = args Detailed Description The text for this alert is generated by the controller and can vary depending on the sit
CTL56 Message arg1 event log: arg2 Arguments arg1 = Controller name, arg2 = args Detailed Description The text for this alert is generated by the controller and can vary depending on the situation. This text is from events in the controller event log that were generated while Storage Management was not running. Recommended Response Action See the hardware documentation for more information.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL58 Message arg1 SAS SMP communications error arg2 Arguments arg1 = Controller name, arg2 = args Detailed Description The text for this alert is generated by the firmware and can vary depending on the situation.
Arguments arg1 = Controller name, arg2 = args Detailed Description There may be a problem with the enclosure. Verify the health of the enclosure and its components. To verify the health of the enclosure, select the enclosure object in the tree view. The Health sub-tab displays a red X or yellow exclamation point for enclosure components that are failed or degraded. See the enclosure documentation for more information. Recommended Response Action There may be a problem with the enclosure.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL60 Message A user has discarded data from the arg1 cache. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Detailed Description The controller has detected a change in the storage configuration between since its last shut down. This can generally happen if some configured physical disks are removed from the system when the system was shutdown. Recommended Response Action Shut down the system. Re-insert the removed physical disks and re-start the system.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ CTL63 Message Previous configuration was found completely missing during boot time on arg1 . Arguments arg1 = Controller name Detailed Description The controller is unable to retrieve storage configuration saved during last shut down. This can generally happen if some configured physical disks are removed from the system when the system was shutdown. Recommended Response Action Shut down the system.
Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2371 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL65 Message Attempted to import Unsupported Virtual Disk type RAID arg1 on arg2 .
Arguments arg1 = args, arg2 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL68 Message Attempted to import Virtual Disk with missing Physical Disk on arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Trap/EventID 4331 OMSA Event ID 2376 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL7 Message Bad block medium error on arg1 . Arguments arg1 = Controller name Detailed Description A portion of a physical disk is damaged.
CTL70 Message Attempted to import an orphan drive on arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ CTL72 Message The foreign configuration overflow has occurred on arg1 . Arguments arg1 = Controller name Detailed Description There is too much foreign configuration data to be imported in one attempt. Recommended Response Action Import these foreign configurations in multiple attempts.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ CTL75 Message Preserved cache discarded on arg1 . Arguments arg1 = controller name Detailed Description The controller cache was discarded by the user. Data may have been lost or corrupted. Recommended Response Action If data was corrupted or lost, restore the data to the disk from a backup copy.
Trap/EventID 4329 OMSA Event ID 2401 OMSA Trap ID 75400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL77 Message Flash of new firmware image(s) completed on arg1 Arguments arg1 = Controller Name Detailed Description This alert message occurs if controller firmware is flashed successfully.
Detailed Description This alert message occurs if controller firmware is flashed. Recommended Response Action No response action is required.
CTL8 Message Bad block extended sense error on arg1 . Arguments arg1 = Controller name Detailed Description A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information. Recommended Response Action See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC Remote System Log WS Eventing ✔ ✔ LC Log LCD ✔ ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔ CTL81 Message Security key assigned to arg1 is modified. Arguments arg1 = controller name Detailed Description The security key assigned to the controller identified in the message is modified. Recommended Response Action No response action is required.
Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) Filter Visibility iDRAC ✔ CMC ✔ LC Log IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy iDRAC CMC CTL83 Message Communication with arg1 has been lost. Arguments arg1 = controller name Detailed Description The management controller is not communicating with the storage controller identified in the message.
Detailed Description The firmware on the controller identified in the message is not supported by this version of the CMC. This may result in degraded functionality. Recommended Response Action Update the CMC Firmware to the latest version available or revert the controller firmware to a previous version.
CTL86 Message arg1 is operating in Fault Tolerant Mode. Arguments arg1 = controller name Detailed Description The controller is operating in conjunction with another controller to service the same set of virtual and physical disks, providing better redundancy. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ CTL88 Message arg1 firmware does not match the firmware of its peer controller. Arguments arg1 = controller name Detailed Description The firmware running on the controller identified in the message does not match the firmware version of its peer controller. This can cause issues in a fault tolerant setup.
Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔ IPMI Alert LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL9 Message Bad block extended medium error on arg1 . Arguments arg1 = Controller name Detailed Description A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Detailed Description The peer controller is not compatible with the controller identified in the message because of a hardware mismatch. Recommended Response Action Replace the peer controller with the same model controller as the controller identified in the message.
CTL92 Message arg1 is not operating in Fault Tolerant Mode because of an incompatible license setting on its peer controller. Arguments arg1 = controller name Detailed Description The controller identified in the message licensed features do not match its peer. Recommended Response Action Update the license on the peer controller.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ CTL94 Message arg1 has been successfully changed to operate in single controller mode. Arguments arg1 = controller name Detailed Description The controller identified in the message has been changed to operate as a single controller and not as part of a fault tolerant pair. Recommended Response Action No response action is required.
Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔ IPMI Alert LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL96 Message arg1 has entered safe mode with limited functionality due to arg2 Arguments arg1 = controller name, arg2 = controller message Detailed Description The controller identified in the message has an issue as displayed in the message.
Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2446 OMSA Trap ID 75100 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CTL98 Message Security key assigned to arg1 .
CTL99 Message Security key assigned to arg1 is deleted. Arguments arg1 = controller name Detailed Description The security key assigned to the controller identified in the message is deleted. Recommended Response Action No response action is required.
DH Event Messages 12 DH001 Message Resource needed to perform the operation is unavailable. Detailed Description Resource temporarily unavailable Recommended Response Action Try again. If the error persists, use RACADM command racreset to clear the issue. Category Configuration (DH = Cert Mgmt) Severity Severity 2 (Warning) No alerts are applicable for this message DH002 Message Internal I/O failure Detailed Description Internal I/O failure Recommended Response Action Try again.
DH004 Message iDRAC does not have sufficient free resources to generate keys Detailed Description Error generation Keys Recommended Response Action Boot the OS. If the error persists, contact technical support. Category Configuration (DH = Cert Mgmt) Severity Severity 1 (Critical) No alerts are applicable for this message DH005 Message CA Cert is corrupted, expired, or does not have signing privileges.
Detailed Description CA priv key/CA Cert mismatch Recommended Response Action Check that the private key parameter is correct. The passphrase can be validated against the private key, passphrase, and certificate can be validated using OpenSSL tools. Category Configuration (DH = Cert Mgmt) Severity Severity 3 (Informational) No alerts are applicable for this message DH008 Message There was a problem saving the certificate to persistent storage.
Recommended Response Action Reset the iDRAC. The iDRAC can be reset by pressing the Identify button for 15 seconds.
13 DIAG Event Messages DIAG0000 Message Pass Detailed Description All Tests passed Recommended Response Action OK, life is good. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0111 Message CPU arg1 : arg2 exception occurred.
DIAG0112 Message CPU arg1 - Machine check exception detected. Arguments arg1 = Cpu Number Detailed Description Recommended Response Action Issue is on system board. Recommend flash the latest BIOS and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0114 Message Cache integrity test discrepancy arg1 Arguments arg1 = Error Reason Detailed Description Depends on .
Arguments arg1 = Degrees, arg2 = Degrees Detailed Description Recommended Response Action Check fans. Check for obstructed air vents. Check for excessive amounts of dust. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0121 Message Memory errors detected, but successfully resolved.
DIAG0123 Message UEFI: Memory error detected. :OR: LEGACY: Memory - integrity test discrepancy. Detailed Description Recommended Response Action MemRX not enabled or not supported. Servers UEFI: Power down system and reseat DIMMS. Retry test and if no error occurs it was a DIMM connection issue. Client LEGACY: Power down system and re-seat DIMMS. Retry test and if no error occurs it was a DIMM connection issue. Check for latest BIOS.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0125 Message The event log indicates degraded or disabled ECC functionality. Memory testing cannot continue until the problems are corrected, the log cleared and the system rebooted. Detailed Description IPMI System Event Log is full for various reasons or logging has stopped because too many ECC errors have occurred. Recommended Response Action Clear the log and reboot and retest.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0131 Message Battery - The battery is not installed. Detailed Description Recommended Response Action Install the battery but check for debris or damaged contacts. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG0132 Message Battery - The battery is reaching the end of its usable life.
DIAG0141 Message Hard Drive - No Hard Drive detected. Detailed Description Recommended Response Action Hard drives are not required on all systems so this message is usually a warning. Desktops and Servers: If the system has a hard disk, power down system and check the signal and power connections to it. Rerun the diagnostic. If no error occurs then it was a cable or connector issue.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0143 Message Hard Drive arg1 - SMART read command unsuccessful. Arguments arg1 = Drive Location Detailed Description Mainly seen with very old hard drives Recommended Response Action No response action is required. Category Storage (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0144 Message Hard Drive arg1 - self test not supported.
Category Storage (DIAG = Diagnostic) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0146 Message Hard Drive arg1 - S/N arg2 , self test log contains previous error(s). Arguments arg1 = Drive Location, arg2 = Serial Number Detailed Description Prior failure checking removed, is now obsolete.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0148 Message Hard/Optical Drive arg1 - incorrect status: arg2 arg3 . Arguments arg1 = Nth Drive, arg2 = Hex, arg3 = Error Reason Detailed Description Recommended Response Action No response action is required.
Recommended Response Action Hard drives on desktops should be found if connected to the chipset disk controller but PERC/SCU/SAS Adapters are not supported by legacy ePSA so if the hard drive is connected to these controllers this message is just a warning. If the system has a hard disk connected to the System Board chipset disk controller, power down the system and check the signal and power connections to it. Rerun the diagnostic. If no error occurs then it was a cable or connector issue.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0152 Message Optical Drive arg1 - Incorrect status = arg2 arg3 . Arguments arg1 = Nth Drive, arg2 = Hex, arg3 = Error Reason Detailed Description Recommended Response Action Check the drive cables and connections. If error persists, make sure that drive firmware and BIOS are current. The <80000000000000??> value is an EFI error code returned by the driver.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0155 Message Hard Drive - Not installed. Detailed Description Recommended Response Action Power down system and check the signal and power connections to the hard drive. Rerun the diagnostic. If no error occurs then it was a cable or connector issue.
Detailed Description Recommended Response Action Replace the CMOS battery and retry the diagnostic. If the error persists, make sure the BIOS is current and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0221 Message System board - Interval timer not functional. Detailed Description Recommended Response Action Make sure the BIOS is current and retry the diagnostics.
Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0234 Message System board - HPET arg1 , incorrect time period. Expected = arg2 , Found = arg3 . Arguments arg1 = 1, arg2 = Decimal, arg3 = Decimal Detailed Description Recommended Response Action Make sure the BIOS is current and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0235 Message PM timer 1 had wrong time period.
DIAG0242 Message System board - Interrupt controller, IRQ = arg1 : arg2 not detected. Arguments arg1 = Decimal, arg2 = IRQ Description Detailed Description Recommended Response Action Make sure the BIOS is current and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0243 Message USB controller error.
DIAG0245 Message Timeout waiting for the device to respond. Detailed Description Recommended Response Action Ensure that the USB device is correctly inserted or try another USB port and/or to see if it is just a particular device or port. After corrective action, rerun the diagnostics. If the problem persists, ensure that BIOS is current.
Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) No alerts are applicable for this message DIAG0314 Message Thermal: The ( arg1 ) reading ( arg2 C) exceeds the thermal limit. Arguments arg1 = Sensor Name, arg2 = Degrees Detailed Description Recommended Response Action Check the event log for thermal events, including defective fans and defective sensors. Inspect the system for clogged or obstructed air vents. Make sure that the BIOS is current and rerun the diagnostics.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0321 Message LCD EDID - Unable to access EDID EEPROM. Detailed Description Recommended Response Action This could relate to the LCD connector and cables. Otherwise, flash the latest BIOS and retry diagnostics.
Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) No alerts are applicable for this message DIAG0324 Message LCD panel - User reported LCD BIST colors were not displayed. Detailed Description Recommended Response Action Possible user error, make sure that the BIOS is current and retry diagnostics.
DIAG0327 Message LCD panel - Unable to use BIOS interface. Detailed Description Recommended Response Action Make sure that the BIOS is current and retry diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0328 Message LCD panel - Unable to detect variance in ambient light sensor. Detailed Description Recommended Response Action Make sure that the BIOS is current and retry diagnostics.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0332 Message Video memory - Video memory integrity test discrepancy. Detailed Description Recommended Response Action Make sure that the BIOS is current and retry diagnostics.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0334 Message Video - User reported the patterns were not displayed. Detailed Description Recommended Response Action Possible user error. Otherwise, make sure that BIOS is current and retry diagnostics.
Arguments arg1 = AUX LCD Name Detailed Description Recommended Response Action No response action is required. Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) No alerts are applicable for this message DIAG0413 Message Cables - arg1 not detected. Arguments arg1 = LCD Name Detailed Description Recommended Response Action No response action is required.
Detailed Description Recommended Response Action Connect the described cable, jumper, sensor, or connection and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0511 Message Fan - The ( arg1 ) fan failed to respond correctly.
Arguments arg1 = Name Detailed Description Recommended Response Action Retry the diagnostics; if the problem persists, the fan is faulty. Make sure that the BIOS is current and retry the diagnostics.
DIAG0621 Message Network arg1 - Driver version arg2 outdated. Version arg3 or newer required for " arg4 " Arguments arg1 = Number, arg2 = Hex, arg3 = Hex, arg4 = EFI Driver Name Detailed Description Test only warns because UEFI Network Driver is old and has known false failures. Recommended Response Action Update Network firmware.
Detailed Description Recommended Response Action Should not occur Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8003 Message Fan - Unable to set Manufacturing Mode.
Detailed Description Recommended Response Action Should not occur Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8005 Message LCD BIST not supported. or Fan - Fan speed failure. Expected at least arg1 , observed arg2 .
DIAG8006 Message Fan - Unable to set fans to arg1 speed.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8008 Message Out of memory! fMalloc() Failed! :OR: Unable to allocate memory for object data. :OR: Unable to arg1 testable memory. :OR: Unable to start application processor(s) :OR: Unable to stop all APs. The system may be unstable and should be rebooted. Arguments arg1 = Name Detailed Description Recommended Response Action Software error, should not normally occur in field.
DIAG800B Message Retrieve vendor ID function error. Detailed Description Recommended Response Action No response action is required. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG800C Message Get/Set inverter mode function error. Vendor: arg1 Revision: arg2 . Arguments arg1 = Name, arg2 = Decimal Detailed Description Recommended Response Action No response action is required.
DIAG800E Message Set lamp on function error. Vendor: arg1 Revision: arg2 . Arguments arg1 = Name, arg2 = Decimal Detailed Description Recommended Response Action No response action is required. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG800F Message Restore function error. Vendor: arg1 Revision: arg2 .
DIAG8011 Message Invalid status return from the device. Detailed Description Recommended Response Action Software error, should not normally occur in field. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG8012 Message Invalid parameter passed to the device.; Unknown test ( arg1 ) selected. Arguments arg1 = Decimal Detailed Description Recommended Response Action Software error, should not normally occur in field.
DIAG8014 Message ADDF module ( arg1 ) device ( arg2 ) failed with error code arg3 , number arg4 . No EPSA beep code mapped. Arguments arg1 = Name, arg2 = Name, arg3 = Hex, arg4 = hex Detailed Description Recommended Response Action Software error, should not normally occur in field. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG8015 Message Unable to stop all APs. The system may be unstable and should be rebooted.
Recommended Response Action Software error, should not normally occur in field. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG8017 Message Battery - BIOS has no support for battery health. Detailed Description Recommended Response Action Software error, should not normally occur in field.
DIAG8020 Message Low memory. arg1 k bytes free! Arguments arg1 = Decimal Detailed Description Recommended Response Action Software error, should not normally occur in field. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG8021 Message SMBIOS DIMM configuration did not match. Detailed Description Recommended Response Action Software error, should not normally occur in field.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8155 Message Tape Drive arg1 - S/N arg2 , data read does not match data written. Arguments arg1 = Drive Location, arg2 = Serial Number Detailed Description Data written on the tape read back differently, not as expected. Recommended Response Action Use a different tape media.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8157 Message arg1 Drive arg2 - S/N arg3 , drive is not a supported drive. Arguments arg1 = Tape|Disk, arg2 = Drive Location, arg3 = Serial Number Detailed Description If then only Dell tape drives are tested and supported.
Recommended Response Action Retry test. If failure persists and BIOS is up to date, a hardware problem is indicated. Category Storage (DIAG = Diagnostic) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8160 Message PERC Battery arg1 - incorrect status = arg2 \n arg3 .
DIAG8166 Message OS - Suspect corrupt MBR, verify MBR with Anti-Virus Application. Detailed Description Recommended Response Action Run virus scan.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8171 Message PCIe - PCI device in physical Slot arg1 , PciTag arg2 , is present but not responding Arguments arg1 = decimal, arg2 = hex Detailed Description A PCI adapter was detected as present but it does not respond to PCI Configuration Space access, so is very sick or not inserted sungly in the PCI physical slot connector Recommended Response Action Reseat or replace PCI adapter in the PCI slot indicated C
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8611 Message User reported not hearing speaker tone Detailed Description Recommended Response Action If the beep was not heard, verify the internal speakers are connected properly. On some systems, internal speakers are a purchased option.
14 DIS Event Messages DIS001 Message Auto Discovery feature not licensed. Detailed Description Auto Discovery starts automatically, but was unable to find a valid license. Once you have obtained a valid license and installed it, restart. Recommended Response Action Follow service providers instructions to enable the license.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DIS003 Message Auto Discovery process started. Detailed Description Auto Discovery process will try to connect to a Provisioning Server over the next 24 hours. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DIS005 Message Auto Discovery communicated successfully with Provisioning Server arg1 . Arguments arg1 = provisioning server name Detailed Description Message was sent successfully from Auto Discovery to Provisioning Server to request certificate. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DIS007 Message Unable to notify Provisioning Server of iDRAC IP address change. Detailed Description Unable to connect to Provisioning Server to notify about new iDRAC IP . Recommended Response Action Check Provisioning Server connectivity and retry..
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DIS009 Message Notification of iDRAC IP address changed to arg1 sent to Provisioning Server. Arguments arg1 = new IP address Detailed Description iDRAC IP address sent to Provisioning Server. Recommended Response Action No response action is required.
Category Configuration (DIS = Auto-Discovery) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC DIS011 Message Auto Discovery client using customer signed client certificate. Detailed Description Customer provided client certificate is being used.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC DIS013 Message Auto Discovery client using default client certificate. Detailed Description Default client certificate is being used. Auto Discovery client is using this certificate for the SSL connection with the Provisioning Server.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC DIS015 Message Auto Discovery client using default CA certificate to authenticate Provisioning Server. Detailed Description Auto Discovery client is using the default Certificate Authority certificate to authenticate the Provisioning Server for the SSL connection..
Category Configuration (DIS = Auto-Discovery) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC DIS100 Message The AutoConfig operation is successful.
Recommended Response Action No response action is required. Category Configuration (DIS = Auto-Discovery) Severity Severity 3 (Informational) Trap/EventID 10635 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC DIS102 Message Unable to start the AutoConfig import operation, because the AutoConfig import file is not available.
DIS103 Message The AutoConfig operation is unable to access a network share folder, because incorrect credentials are specified in the DHCP scope option field where the VendorID=iDRAC. Detailed Description The network share folder cannot be accessed by using the credentials specified in the DHCP scope option field where the VendorID=iDRAC.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC DIS105 Message The AutoConfig operation is unable to access the network share folder, because an invalid sharetype value is specified in the DHCP scope option field where the VendorID=iDRAC.
Recommended Response Action Enter a valid shutdown type in the DHCP scope option field where the VendorID=iDRAC using (-d <0 or 1>) where 0 = Graceful shutdown and 1 = Forced shutdown.
DIS108 Message Unable to start the AutoConfig import operation, because Lifecycle Controller is not enabled. Detailed Description The server could not be successfully configured, because Lifecycle Controller is either not installed or not enabled. Recommended Response Action Verify that the Lifecycle Controller firmware on the server being configured is installed and enabled, then restart the iDRAC by pressing the System ID button for 15 seconds.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC DIS110 Message The AutoConfig operation is completed. Detailed Description The AutoConfig operation is completed. Recommended Response Action No response action is required.
15 DKM Event Messages DKM1000 Message A network problem detected. Cannot contact key management server. Detailed Description None Recommended Response Action Check for network connectivity. Review network, server, and client configuration.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DKM1002 Message Key management server certificate problem detected.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DKM1006 Message Key management server error detected. Detailed Description None Recommended Response Action Review server error logs for additional information. Category System Health (DKM = Dell Key Mngr) Severity Severity 1 (Critical) LCD Message Key management server error.
16 ENC Event Messages ENC1 Message arg1 was inserted. Arguments arg1 = Enclosure Management Module Name Detailed Description An Enclosure Management Module (EMM) has failed is inserted into the enclosure. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 4339 OMSA Event ID 2152 OMSA Trap ID 85100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ ENC100 Message arg1 is sending inconsistent responses to the controller.
ENC11 Message The arg1 service tag was changed. Arguments arg1 = enclosure name Detailed Description An enclosure service tag was changed. In most circumstances, this service tag should only be changed by the service provider. Recommended Response Action Make sure that the service tag was changed under authorized circumstances.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC13 Message Unsupported configuration detected on arg1 . arg2 arg3 Arguments arg1 = Enclosure Name, arg2 = EMM0 1, arg3 = EMM1 2 Detailed Description An unsupported configuration was detected. The SCSI rate of the Enclosure Management Modules (EMMs) are not the same.
Detailed Description There are too many enclosures attached to the controller port. When the enclosure limit is exceeded, the controller loses contact with all enclosures attached to the port. This is an unsupported configuration. Recommended Response Action Remove the extra enclosures. Refer to the storage hardware documentation for maximum number of enclosures that can be connected.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ ENC16 Message An enclosure blink has ceased on arg1 . Arguments arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Trap/EventID 4339 OMSA Event ID 2291 OMSA Trap ID 85100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ ENC18 Message Communication with arg1 was lost. Arguments arg1 = enclosure name Detailed Description The controller has lost communication with an Enclosure Management Module (EMM). The cables may be loose or defective.
ENC19 Message arg1 has failed. Arguments arg1 = Enclosure Management Module Name Detailed Description An Enclosure Management Module (EMM) has failed. The failure may be caused by a loss of power to the EMM. The EMM self-test may also have identified a failure. There may also be a firmware problem or a multi-bit error. Recommended Response Action Reset the Enclosure Management Module (EMM). See the storage hardware documentation for information on replacing the EMM. Replace the EMM.
OMSA Trap ID Filter Visibility 95400 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC21 Message arg1 has been removed. Arguments arg1 = Enclosure elements name Detailed Description A device has been removed and the system is no longer functioning in optimal condition. Recommended Response Action Replace the device.
Detailed Description The enclosure has a bad sensor. The enclosure sensors monitor the fan speeds, temperature probes, and so on. Recommended Response Action Refer to the storage hardware documentation for more information.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ ENC24 Message Communication with arg1 is intermittent. Arguments arg1 = enclosure name Detailed Description The controller is not receiving a consistent response from the enclosure. There could be a firmware problem or an invalid cabling configuration. If the cables are too long, they degrade the signal. Recommended Response Action Power down all enclosures attached to the system and reboot .
Category Storage (ENC = Storage Enclosr) Severity Severity 1 (Critical) Trap/EventID 4337 OMSA Event ID 2301 OMSA Trap ID 85400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC26 Message arg1 is not responding.
ENC27 Message SAS or SATA mixing of physical disks is not supported within the arg1 . Arguments arg1 = Enclosure Name Detailed Description The enclosure cannot support both SAS and SATA physical disks. Physical disks may be disabled. This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Event ID 2311 OMSA Trap ID 85300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC29 Message arg1 temperature has returned to normal. Arguments arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Arguments arg1 = Enclosure Name Detailed Description The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature range. Recommended Response Action Check for factors that may cause overheating or excessive cooling. For example, verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ ENC31 Message Firmware download on arg1 has failed. Arguments arg1 = Enclosure Name Detailed Description The system was unable to download firmware to the enclosure. The controller may have lost communication with the enclosure.
Arguments arg1 = Enclosure Name Detailed Description The SEP has been rebooted as part of the firmware download operation and will be unavailable until the operation completes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ ENC4 Message arg1 firmware mismatch. Arguments arg1 = Enclosure Name Detailed Description The firmware on the EMM modules is not the same version. It is required that both modules have the same version of the firmware. This alert may be caused when you attempt to insert an EMM module that has a different firmware version than an existing module.
Category Storage (ENC = Storage Enclosr) Severity Severity 3 (Informational) Trap/EventID 4339 OMSA Event ID 2190 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC5 Message Redundancy on arg1 is degraded Arguments arg1 = Enclosure Name Detailed Description One or more of the enclosure components
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ ENC6 Message Communication timeout on arg1 . Arguments arg1 = Enclosure Name Detailed Description The controller is unable to communicate with an enclosure. There are several reasons for communication loss. For example, there may be a bad or loose cable. An unusual amount of I/O may also interrupt communication with the enclosure.
Detailed Description You have enabled the enclosure alarm. This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ ENC9 Message The arg1 asset tag was changed. Arguments arg1 = Enclosure Name Detailed Description You have changed the enclosure asset tag. This alert is provided for informational purposes. Recommended Response Action No response action is required.
17 EPP Event Messages EPP001 Message Unable to use the Extended Power Performance (EPP) feature on chassis. Detailed Description The Extended Power Performance cannot be used unless chassis has six EPP capable PSUs, Configure the Power Redundancy Policy to Grid Redundancy & MPCM, DPSE, SBPM and Fresh Air features should be disabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC EPP003 Message Unable to use the Extended Power Performance (EPP) feature because the Dynamic Power Supply Engagement mode is enabled. Detailed Description The Extended Power Performance cannot be used because the Dynamic Power Supply Engagement mode is enabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC EPP005 Message Unable to set the Extended Power Performance (EPP) feature because the Server Based Power Management mode is enabled. Detailed Description The Extended Power Performance cannot be used because the Server Based Power Management mode is enabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC EPP007 Message Unable to use the Extended Power Performance (EPP) feature because the Chassis Management Controller (CMC) firmware update is in progress. Detailed Description The Extended Power Performance cannot be used because the Chassis Management Controller (CMC) firmware update is in progress.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC EPP009 Message Unable to use the Extended Power Performance (EPP) feature because the Grid Redundancy feature is not available. Detailed Description The Extended Power Performance cannot be used because the Grid Redundancy feature is not available.
Category System Health (EPP = Extended Power Performance) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC EPP011 Message Unable to use the Extended Power Performance (EPP) feature because the power supply unit (PSU) slot - arg1 has no input power.
Detailed Description The Extended Power Performance cannot be used because the power supply unit (PSU) slot identified in the message has no output power. Recommended Response Action Make sure that the PSU in the PSU slot has no issue in the output power, and then retry to enable the EPP feature. To check the health status of the PSU identified in the message using the RACADM CLI utility, enter the following command: "racadm getpbinfo".
EPP014 Message Unable to use the Extended Power Performance (EPP) feature because the Redundancy Policy is not set to Grid Redundancy. Detailed Description The Extended Power Performance is cannot be used because the Redundancy Policy is not set to Grid Redundancy. Recommended Response Action Configure the Power Redundancy Policy to Grid Redundancy and retry to enable the EPP feature.
LC Log iDRAC CMC 502 LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
18 FAN Event Messages FAN0000 Message Fan arg1 RPM is less than the lower warning threshold. Arguments arg1 = number Detailed Description The fan is not performing optimally. The fan may be installed improperly or may be failing. Recommended Response Action Remove and re-install the fan at the next scheduled service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Trap/EventID 2153 LCD Message Fan RPM is outside of range. Check fan. Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy FAN0002 Message Fan arg1 RPM is greater than the upper warning threshold. Arguments arg1 = number Detailed Description The fan is not performing optimally.
Detailed Description The fan is not performing optimally. The fan may be installed improperly or may be failing. Recommended Response Action Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (FAN = Fan Event) Severity Severity 1 (Critical) Trap/EventID 2153 LCD Message Fan RPM is outside of range. Check fan.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy FAN0005 Message Fan arg1 RPM is within range. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ FAN0007 Message Fan arg1 was inserted. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Category System Health (FAN = Fan Event) Severity Severity 3 (Informational) Trap/EventID 2155 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* FAN0009 Message Fan arg1 is absent. Arguments arg1 = number Detailed Description The fan may be required for optimal performance.
Arguments arg1 = number Detailed Description The fan may be required for optimal performance. Recommended Response Action No response action is required. Category System Health (FAN = Fan Event) Severity Severity 2 (Warning) Trap/EventID 2154 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC FAN0011 Message Fan arg1 is enabled.
FAN0012 Message arg1 RPM is less than the lower warning threshold. Arguments arg1 = fan name Detailed Description The device is not performing optimally. The device may be installed improperly. Recommended Response Action Remove and re-install the device at the next scheduled service. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* FAN0014 Message arg1 RPM is greater than the upper warning threshold. Arguments arg1 = fan name Detailed Description The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
FAN0017 Message arg1 RPM is within normal operating range. Arguments arg1 = fan name Detailed Description The RPM of the fan identified in the message is functioning correctly. Recommended Response Action No response action is required.
Arguments arg1 = fan number Detailed Description An incompatibility between operating mode and fan type was corrected for the fan identified in the message. Recommended Response Action No response action is required. Category System Health (FAN = Fan Event) Severity Severity 3 (Informational) No alerts are applicable for this message FAN0020 Message The arg1 is non-functional.
Recommended Response Action Re-install the fan, and open the OMSA Web interface to verify if the fan identified in the message is displayed correctly. If the issue persists, contact your service provider.
FAN0023 Message Unable to read the arg1 sensor value. Arguments arg1 = sensor name Detailed Description The fan sensor identified in the message has failed or the fan has failed. Recommended Response Action Do the following: 1) Remove the old fan, install a new fan and power cycle the system to check if the fan is working properly, 2) Replace the system board if the fan sensor has failed. 3) If the issue persists, contact your service provider.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC FAN0025 Message The arg1 sensor state has changed to a warning state with a value of arg2 RPM. Arguments arg1 = sensor name, arg2 = fan speed Detailed Description The fan identified in the message is not functioning correctly. The fan may be installed incorrectly or may be failing.
Recommended Response Action Remove and re-install the fan, or replace the fan with a new fan. If the issue persists, contact your service provider.
FAN1000 Message arg1 was removed. Arguments arg1 = Fan Sensor Name Detailed Description The enclosure detected that a fan was removed and the enclosure is no longer functioning in optimal condition.. Recommended Response Action Re-insert the fan into the enclosure. Contact technical support if the issue persists.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* FAN1002 Message arg1 has failed. Arguments arg1 = Fan Sensor Name Detailed Description The enclosure detected that a fan has failed and the enclosure is no longer functioning in optimal condition.. Recommended Response Action Contact technical support.
FAN8501 Message Enhanced Cooling Mode is Disabled Detailed Description Disabling Enhanced Cooling Mode allows for reduced power consumption by reducing the maximum speed of the blowers while still providing sufficient blade airflow. Recommended Response Action No response action is required.
Detailed Description The Chassis was turned off because more than two Chassis internal fans stopped functioning. The fans with issues are identified in the CMC Hardware (System Event Log) and Chassis Logs. Recommended Response Action Make sure that the Chassis internal fans are functioning. At the command line interface (CLI), enter the following command to identify fans that are not functioning: "racadm getsel". Using the CMC Web GUI, select the chassis, click the Logs tab, and then select Hardware Log.
FAN901 Message The Enhanced Cooling Mode is successfully disabled. Detailed Description The Enhanced Cooling Mode is successfully disabled. Recommended Response Action No response action required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FAN903 Message Cannot enable the Enhanced Cooling Mode because an unsupported fan is inserted in the Chassis. Detailed Description The Enhanced Cooling Mode cannot be enabled because an unsupported fan is present in the Chassis. Recommended Response Action Insert a fan that is supported by the Chassis, and then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FAN905 Message Applying fan configuration settings. This may take several seconds. Detailed Description Applying fan configuration settings. This may take several seconds. Recommended Response Action No response action required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FAN907 Message The Enhanced Cooling Mode feature is already enabled. Detailed Description The Enhanced Cooling Mode feature is already enabled. Recommended Response Action No response action required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FAN911 Message The attempt to enable the Enhanced Cooling Mode was not successful. Detailed Description The attempt to enable the Enhanced Cooling Mode (ECM) was not successful because ECM is already enabled or Gen3 fans are not present in the Chassis.
19 FC Event Messages FC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration (FC = Fiber Channel) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FC002 Message Unable to allocate memory.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FC003 Message Missing required parameter. Detailed Description An invalid number of arguments was provided to the method. Recommended Response Action Enter required input parameters and retry. For more information, see Lifecycle Controller Users Guide or the FC HBA Profile specification.
FC005 Message The number of AttributeName array elements does not match the AttributeValue array element count. Detailed Description The number of AttributeName and AttributeValue array elements are not equal. Recommended Response Action Provide equal number of array elements for AttributeName and AttributeValue parameters. For more information about input parameters, see FC HBA Profile specification.
FC008 Message No pending data present to create a Configuration job. Detailed Description No changes are available between the previous configuration and the current configuration. To create a Configuration job, change at least one attribute. Recommended Response Action Change the configuration of one or more attributes and retry creating the Configuration job.
Severity Severity 2 (Warning) No alerts are applicable for this message FC011 Message Configuration job already created, pending data cannot be deleted Detailed Description Configuration job already created on the specified target. No further command is allowed until the existing job is completed. Recommended Response Action Cancel the configuration job or wait for the job to complete. Refer to documentation on job cancellation.
FC014 Message Invalid AttributeValue parameter content for corresponding AttributeName arg1 . Arguments arg1 = parameter name Detailed Description The AttributeValue parameter is invalid due to one of the following: 1) The length of new AttributeValue is not within the minimum length and maximum length range or does not comply with the governing regular expression 2) Value of new AttributeValue is not within the lower bound and upper bound range limits 3) The value is not one of the possible values.
No alerts are applicable for this message FC017 Message Unable to perform the operation due to an internal error in iDRAC. Detailed Description An internal error occurred in iDRAC and the operation cannot continue. An iDRAC reset is required to recover from the error. Recommended Response Action Disconnect the AC power source from the system, reconnect the power source, and retry the operation.
FC103 Message The FC arg1 port arg2 network connection is successfully started. Arguments arg1 = controller ID, arg2 = port ID Detailed Description The network connection of the FC controller port link identified in the message is successfully started. Recommended Response Action No response action required.
20 FCD Event Messages FCD8500 Message Unable to apply the arg1 configuration. The affected servers (slot arg2 ) are not turned off. Arguments arg1 = configuration name, arg2 = slot number Detailed Description The server specified in the message must be turned off or the server slot must be empty before changing the FlexAddress configuration. Recommended Response Action Turn off the server and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* FCD8503 Message The feature is activated in the chassis: arg1 Arguments arg1 = feature name Detailed Description Chassis already has the feature identified in the message activated. Only one instance of a feature can be activated at a time.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* FCD8505 Message The features cannot be deactivated when the chassis is turned on. Detailed Description Features cannot be deactivated when the chassis is turned on.
Recommended Response Action Contact your service provider.
21 FLDC Event Messages FLDC1001 Message The journal mirror at path = arg1 is available. Arguments arg1 = World Wide Name Detailed Description The entry in the journal for the device identified in the message with the WWN (World Wide Name) is available. Recommended Response Action No response action is required.
OMSA Event ID 2701 OMSA Trap ID 160100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1003 Message Cache flushing has started for the virtual disk with WWN = arg1 and path = arg2 . Arguments arg1 = World Wide Name, arg2 = device pathname Detailed Description The cache flushing operation has started for the virtual disk identified in the message.
Arguments arg1 = World Wide name, arg2 = device pathname Detailed Description The cache flushing operation has completed for the virtual disk identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1007 Message The cache device arg1 with WWN = arg2 and path = arg3 is removed. Arguments arg1 = physical disk Name, arg2 = World Wide Name, arg3 = device pathname Detailed Description The cache device identified in the message is removed from the Fluid Cache configuration. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 90100 IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1009 Message Caching is being removed for the arg1 with WWN = arg2 and path = arg3 . Arguments arg1 = virtual disk name, arg2 = World Wide Name, arg3 = device pathname Detailed Description Caching is being removed for the virtual disk identified in the message.
Detailed Description Caching is enabled on the virtual disk identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1013 Message The cached LUN with WWN = arg1 and path = arg2 for arg3 has had a failure. Arguments arg1 = World Wide Name, arg2 = device pathname, arg3 = virtual disk name Detailed Description The cached LUN identified in the message has had a failure to successfully perform a read or write operation.
Severity Severity 3 (Informational) OMSA Event ID 2912 OMSA Trap ID 90100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1015 Message Recovery of the cache device arg1 with wwn = arg2 and path = arg3 is complete.
Detailed Description A valid permanent license is installed for Fluid Cache. Recommended Response Action No response action is required.
FLDC1018 Message A license has been removed for Fluid Cache. Detailed Description A license has been removed for Fluid Cache. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1020 Message The storage device with WWN = arg1 and path = arg2 is in unknown state. Arguments arg1 = wwn name, arg2 = path name Detailed Description The storage device identified in the message is in unknown state. Recommended Response Action Service is required. Contact your service provider.
Category Storage (FLDC = Unknown) Severity Severity 2 (Warning) OMSA Event ID 2702 OMSA Trap ID 160300 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1022 Message The associated server of the Cache Device arg1 with WWN = arg2 is not configured.
FLDC1023 Message Fluid Cache is running on an evaluation license and the evaluation license expires in arg1 days. Arguments arg1 = days Detailed Description Fluid Cache is currently running on an evaluation license and the evaluation license expires in the number of days identified in message. Recommended Response Action A permanent license for Fluid Cache should be purchased for continued service.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1025 Message Caching was enabled in write-back or write-through mode, it is currently operating in pass-through mode. Detailed Description Caching was enabled in write-back mode or write through mode, but currently it is operating in write-through mode because fluid Cache Pool has no PCIe-SSD device.
Recommended Response Action No response action is required.
FLDC1028 Message OMSS Connection to Fluid Cache service is no longer present. Detailed Description The communications connection between OMSS and the Fluid Cache service is no longer present. Recommended Response Action To reconnect OMSS to the Fluid Cache service: 1) Verify the Fluid Cache service is running. To verify the service run the following command: "fldc --status".
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1030 Message The cluster ID in the journal does not match the cluster ID in the configuration file for Fluid Cache. Detailed Description An Inconsistency was found in Fluid Cache configuration data. Recommended Response Action Service is required. Contact your service provider.
Category Storage (FLDC = Unknown) Severity Severity 1 (Critical) OMSA Event ID 2705 OMSA Trap ID 160400 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1032 Message The cache device with WWN = arg1 and path = arg2 is no longer functional.
FLDC1033 Message The storage device WWN = arg1 and path = arg2 is either inaccessible or no longer functional. Arguments arg1 = wwn name, arg2 = path name Detailed Description The message indicates that the storage device is either inaccessible or is no longer functional. Recommended Response Action If the virtual disk is inaccessible, restore accessibility by bringing the virtual disk back online.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1035 Message Configuration changes are not allowed, because Fluid cache is running on an expired evaluation license (Expired days: arg1 ). Arguments arg1 = number of days Detailed Description Configuration changes are not allowed because Fluid Cache is running on an expired evaluation license.
Detailed Description Caching functionality is disabled because Fluid cache is running on an expired evaluation license. The message also indicates the number of days that Fluid Cache has been running with an expired license (maximum 30 days after expiration are allowed). Recommended Response Action Install a permanent Fluid Cache license.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1038 Message There is not enough memory capacity to run necessary services for Fluid Cache. Detailed Description There is not enough memory capacity to run necessary services for Fluid Cache. Recommended Response Action The minimum memory required to run Fluid Cache for DAS is 16 GB. For optimum operation, recommendation is to install 32 GB of RAM.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC CMC 562 ✔ LCD OS Log ✔ Power Off Power Cycle Reset Chassis Event Proxy
22 FSD Event Messages FSD000 Message Debug authorized by customer; debugcaps: arg1 , was authorized by: arg2 , at arg3 for the period: arg4 to arg5 . Arguments arg1 = DebugCaps, arg2 = iDRAC User, arg3 = unblock time, arg4 = start time, arg5 = end time Detailed Description The customer has authorized the specified debug capabilities on this iDRAC. (This should occur in response to a request from Dell tech support.
Recommended Response Action DebugCaps;grant time;Dell employee;start time;end time Category Audit (FSD = Debug) Severity Severity 3 (Informational) Trap/EventID 8595 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC FSD002 Message Debug authorization failed; for debugCaps: arg1 , authorized by iDRAC user: arg2 , and Dell employee: arg3 , at arg4 f
23 HWC Event Messages HWC0001 Message Unable to complete the operation as there is no response from iDRAC. Detailed Description The error is caused due to iDRAC failure. Recommended Response Action 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord and turn on the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC0003 Message Successfully initialized vFlash SD card. Detailed Description vFlash SD card was successfully initialized. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC0005 Message Internal error while retrieving update information. Detailed Description Internal error while retrieving firmware version for the currently installed components. For more information about the failure, see Lifecycle Log. Recommended Response Action 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC0007 Message Unable to load vFlash SD card settings. Detailed Description Lifecycle Controller is unable to retrieve vFlash SD card information from iDRAC. Recommended Response Action Reinsert the vFlash SD card and retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC0009 Message Unable to enable vFlash SD card. Detailed Description The vFlash SD card is missing or not inserted correctly. iDRAC is not able to enable vFlash SD card. Recommended Response Action Reinsert the vFlash SD card and retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC0011 Message Insufficient space to copy the file to the USB drive. Detailed Description The USB drive does not have sufficient free space to copy the file. Recommended Response Action Make sure the USB drive has sufficient free space before retrying the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC0013 Message Unable to copy the file to USB drive. Detailed Description The USB drive is disconnected or is not readable. Recommended Response Action Remove and reinsert the USB drive and retry the operation. If the problem persists, restart the system and retry.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC0015 Message iDRAC not responding. Detailed Description iDRAC has encountered a hardware error. Recommended Response Action Retry the operation. If the problem persists, 1) Turn off the system and disconnect the power cord. 2) Wait five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC1000 Message The arg1 is present. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC1002 Message The arg1 is disabled. Arguments arg1 = name Detailed Description None Recommended Response Action If device disabled unexpectedly, re-enable device.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC HWC1004 Message The storage adapter is present. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message The storage adapter is absent. Check hardware Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC1006 Message The storage adapter is disabled. Detailed Description None Recommended Response Action If adapter disabled unexpectedly, re-enable the storage adapter.
Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC HWC1008 Message The backplane is present. Detailed Description None Recommended Response Action No response action is required.
Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message The backplane is absent. Check hardware Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC1010 Message The backplane is disabled. Detailed Description None Recommended Response Action If disabled unexpectedly, re-enable backplane.
Recommended Response Action No response action is required. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC HWC1012 Message The USB cable is present. Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action If removal was unintended, check presence, then re-install or reconnect. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message The USB cable is absent. Check cable Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC1014 Message The mezzanine card arg1 is present.
HWC1015 Message The mezzanine card arg1 is absent. Arguments arg1 = number Detailed Description The mezzanine card may be necessary for proper operation. System functionality may be degraded. Recommended Response Action If removal was unintended, check presence, then re-install or reconnect.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* HWC1101 Message The arg1 is removed from slot arg2 . Arguments arg1 = name, arg2 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* HWC1103 Message The arg1 installed in an unsupported slot arg2 is removed. Arguments arg1 = module name, arg2 = slot number Detailed Description The peripheral sled identified in the message is removed from the unsupported slot identified in the message.
Recommended Response Action Make sure that the peripheral sled identified in the message is supported by the chassis and the CMC firmware. For information about the supported sleds and firmware versions, see the System Manual available at the support site.
HWC1200 Message The sled arg1 is inserted in slot arg2 . Arguments arg1 = sled name, arg2 = slot number Detailed Description The sled identified in the message is inserted in the slot identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* HWC1202 Message The arg1 was installed in slot arg2 . Arguments arg1 = name, arg2 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC2000 Message The arg1 cable or interconnect is connected. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message The cable or interconnect failure. Check connection Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC2002 Message The storage arg1 cable or interconnect is connected.
Arguments arg1 = name Detailed Description The cable may be necessary for proper operation. System functionality may be degraded. Recommended Response Action Check presence, then re-install or reconnect. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message Storage cable or interconnect failure.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* HWC2005 Message The system board arg1 cable or interconnect is not connected, or is improperly connected. Arguments arg1 = name Detailed Description The cable may be necessary for proper operation. System functionality may be degraded. Recommended Response Action Check presence, then re-install or reconnect.
Trap/EventID 2329 LCD Message is not installed correctly. Check connection Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC2007 Message The arg1 is installed correctly. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Detailed Description The fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into the chassis, the fabric type is then set for the CMC and the CMC will ensure that all subsequent IOMs and mezzanine cards match. Recommended Response Action Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card.
HWC2010 Message The riser board cable or interconnect is connected. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC HWC2012 Message A fabric mismatch detected on fabric arg1 with server in slot arg2 . Arguments arg1 = name, arg2 = number Detailed Description The fabric type on the server does not match that of the IO module. Recommended Response Action Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC2014 Message A hardware misconfiguration detected on arg1 . Arguments arg1 = name Detailed Description None. Recommended Response Action Make sure the hardware is installed correctly. Refer to the product documentation for correct configuration and installation procedures.
Recommended Response Action No response action is required. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Trap/EventID 2331 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC3000 Message The arg1 is removed.
HWC3001 Message The arg1 is inserted. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* HWC3003 Message Server arg1 was inserted. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC3005 Message IO module arg1 was inserted. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Do the following: 1) Check the number of reserved IPv4 addresses for QuickDeploy. 2) Modify it such that the newly inserted blade will obtain an IP address for QuickDeploy. 3) Reseat the server to retry the QuickDeploy operation or manually configure the network parameters for the server.
HWC4001 Message A hardware incompatibility was corrected between BMC/iDRAC firmware and CPU. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC HWC4003 Message A hardware incompatibility was corrected between BMC/iDRAC firmware and other hardware. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC4011 Message Hardware unsuccessfully updated for mezzanine card arg1 . Arguments arg1 = number Detailed Description None Recommended Response Action Check presence, re-install or reconnect, then re-attempt the update. If the problem persists, contact support.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC HWC4013 Message Hardware unsuccessfully updated for embedded NIC. Detailed Description None Recommended Response Action Check presence, re-install or reconnect, then re-attempt the update. If the problem persists, contact support.
Trap/EventID Filter Visibility 2331 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC4015 Message Link Tuning error detected. Detailed Description CMC has old firmware and does not recognize the new device which has requested link tuning information. After updating the firmware the CMC will recognize the device.
Recommended Response Action 1) Review system documentation for supported mezzanine cards. 2) Replace mezzanine card with a supported mezzanine card.
HWC4018 Message A hardware incompatibility was corrected between arg1 arg2 and arg3 arg4 . Arguments arg1 = first component name, arg2 = first component location location, arg3 = second component name, arg4 = second component location Detailed Description A hardware incompatibility was corrected between the components identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* HWC5001 Message arg1 is offline. Arguments arg1 = name Detailed Description None Recommended Response Action If unexpected, check presence, then re-install or reconnect.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5003 Message arg1 is operating correctly. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Update the CMC firmware. If the problem persists, contact support. Category System Health (HWC = Hardware Config) Severity Severity 2 (Warning) Trap/EventID 2330 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5006 Message A failure is detected on arg1 .
HWC5008 Message Console is not available for the arg1 . Arguments arg1 = name Detailed Description None Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you. Category System Health (HWC = Hardware Config) Severity Severity 2 (Warning) No alerts are applicable for this message HWC5010 Message arg1 cannot detect any hosts.
HWC5014 Message arg1 is not functional and is powered off. Arguments arg1 = name Detailed Description None Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) No alerts are applicable for this message HWC5030 Message IO module arg1 is online.
Detailed Description The CMC has powered off the IOM. Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
HWC5033 Message IO module arg1 is operating correctly. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* HWC5035 Message An over-temperature event detected on I/O module arg1 . Arguments arg1 = number Detailed Description The I/O module over heated. Recommended Response Action Do the following: 1) Make sure fans are installed and working correctly. 2) Check the temperature sensor status for the chassis and make sure it is within the chassis operating temperature range.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5037 Message I/O module arg1 failed to boot. Arguments arg1 = number Detailed Description The firmware on the I/O module did not boot. The problem may be because the I/O module is not inserted correctly. Recommended Response Action Reseat I/O module.
Category System Health (HWC = Hardware Config) Severity Severity 2 (Warning) Trap/EventID 2330 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC6001 Message The arg1 controller is online. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Detailed Description Information and status from the controller is unavailable. Recommended Response Action Remove and reapply input power. If problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
HWC6004 Message Cannot communicate with arg1 controller. Arguments arg1 = name Detailed Description Information and status from the controller is unavailable. Recommended Response Action Remove and reapply input power. If problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* HWC7000 Message Server arg1 health changed to a normal state. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC7004 Message Server arg1 health changed to a critical state from either a normal or warning state. Arguments arg1 = number Detailed Description Server health changed to a critical state from either a normal or warning state.
Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC7008 Message Server arg1 health changed to a warning state from more severe state.
Detailed Description Server health changed to a critical state from a non-recoverable state. Recommended Response Action Review System Log or front panel for additional information.
HWC7014 Message An invalid cable or incorrect cable configuration is detected. Detailed Description An invalid cable related hardware configuration detected on the system. Recommended Response Action Make sure the hardware and related cables are installed correctly. For information about configuration and installation procedures, see the systems Owners Manual available at the support site.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC8001 Message A device was added to the system at this location: arg1 . Additional Details: arg2 . Arguments arg1 = device location, arg2 = details Detailed Description A device was added to the system at the location identified in the message. Along with the device location, additional event details are provided if available. Recommended Response Action No response action is required.
OMSA Event ID 5652 OMSA Trap ID 5652 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC8003 Message A configuration error was detected in the device located here: arg1 . Additional Details: arg2 .
HWC8004 Message The SD card device sensor has failed. SD card location: arg1 , SD card device type: arg2 , SD card state: arg3 . Arguments arg1 = location, arg2 = type, arg3 = state Detailed Description The SD card device sensor of the type identified in the message has failed. The current status of the SD card is also displayed. Recommended Response Action Reinsert the SD card or try a different SD card and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC8006 Message The SD card device state has changed to a warning state. SD card location: arg1 , SD card device type: arg2 , SD card state: arg3 .
Arguments arg1 = location, arg2 = type, arg3 = state Detailed Description The SD card sensor detected an SD card failure. Recommended Response Action Replace the old SD card with a new SD card.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC8009 Message SD card device sensor value unknown. SD card location: arg1 , SD card device type: arg2 , SD card state: arg3 . Arguments arg1 = location, arg2 = type, arg3 = state Detailed Description An SD card device sensor in the identified system could not obtain a reading. Recommended Response Action Remove and reinsert the identified SD card.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* HWC8502 Message The I/O panel cable is connected. Detailed Description The internal cable that connects the I/O panel to the system board is properly connected. Recommended Response Action No response action is required.
Trap/EventID Filter Visibility 2331 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* HWC8504 Message The Chassis Management Controller (CMC) cannot communicate with the control panel. Detailed Description The control panel is not functioning normally.
Recommended Response Action Remove and reapply chassis input power. If problem persists, contact your service provider.
Detailed Description A device causing an issue in the I/O panel USB port is removed. Recommended Response Action No response action is required.
HWC8510 Message The heat sinks of the PCIe switches are properly attached. Detailed Description The heat sinks of the PCIe switches are properly attached. Recommended Response Action No response action is required.
24 IOID Event Messages IOID001 Message The Input/Output Identity (I/O Identity) optimization feature is enabled. Detailed Description After the I/O Identity optimization feature is enabled, the time during boot to configure I/O Identity attributes using the Server Configuration Profile (Configuration XML) import feature will be significantly reduced. Recommended Response Action No response action required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOID003 Message The Virtual Address Persistence Policy setting for Auxiliary powered devices is changed to arg1 . Arguments arg1 = restart type Detailed Description The Virtual Address Persistence Policy setting for Auxiliary powered devices is changed to the restart type identified in the message.
Category Configuration (IOID = IO Identity Optimization) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOID005 Message Storage Initiator Persistence Policy setting is changed to arg1 .
Recommended Response Action No response action is required. Category Configuration (IOID = IO Identity Optimization) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOID110 Message The virtual address of NIC arg1 Port arg2 is configured.
Arguments arg1 = controller, arg2 = port Detailed Description The virtual address of the NIC port identified in the message could not be successfully configured because either the network port connection is not enabled or the NIC is not capable of Virtual Addressing. Recommended Response Action Verify that the network port is enabled and that the port has Virtual Addressing capability and then retry the operation.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC IOID113 Message Unable to configure the initiator properties of NIC arg1 Port arg2 . Arguments arg1 = Controller, arg2 = Port Detailed Description The initiator properties of the NIC port could not be configured because either iSCSI or FCoE partition of the network port is not enabled, or the network controller is not functioning.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC IOID115 Message Unable to configure the target settings properties of the NIC arg1 Port arg2 .
Category Configuration (IOID = IO Identity Optimization) Severity Severity 3 (Informational) Trap/EventID 10771 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC IOID117 Message The operation to apply I/O Identity settings based on current persistence policy settings has completed successfully.
Detailed Description The iDRAC has applied I/O Identity Configuration on NIC and FC HBA devices. One or more of the setting configuration operations did not complete successfully. Recommended Response Action Review the previous log entries and identify the devices that did not successfully complete configuration operations. For the identified devices, do the following and then restart the server: 1) Make sure the device is installed properly. 2) Make sure the device has latest firmware installed.
LC Log iDRAC CMC 646 ✔* LCD OS Log ✔ Power Off Power Cycle Reset Chassis Event Proxy
25 IOV Event Messages IOV000 Message Successfully completed the operation. Detailed Description This operation was successful. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV002 Message Unable to create or allocate the required resources. Detailed Description CMC could not successfully allocate resources because of the following reasons: 1) The chassis manager is unable to allocate required resources. 2) The chassis manager or chassis infrastructure firmware is rolled back to an earlier version. 3) There is an issue with the internal communications between chassis components.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log Reset Chassis Event Proxy iDRAC CMC IOV004 Message Unable to turn on PCIe adapter.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC CMC WS Eventing ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV006 Message Incorrect Chassis Infrastructure Mainboard firmware version. Detailed Description The Chassis Infrastructure Mainboard firmware is not at the correct version.. Recommended Response Action Run the command "racadm fwupdate -g -u -a -d mainboard.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC Remote System Log WS Eventing ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV008 Message Chassis Management Controller (CMC) is unable to put PCIe subsystem into factory default mode. Detailed Description The Chassis Management Controller (CMC) was unable to reset the PCIe subsystem into factory default mode.
Category Configuration (IOV = IO Virtualization) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC CMC WS Eventing ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV010 Message Unable to assign the PCIe slot(s) because a license is required to assign more than two PCIe slots to a server.
Recommended Response Action Turn off all servers that the PCIe slots or virtual adapter (VA) will be assigned-to and unassigned-from, and then retry the operation.
Detailed Description Unable to assign a virtual adapter (VA) to a server that is already assigned a VA, because a server may be assigned only one VA. Recommended Response Action Unassign the servers current virtual adapter (VA) and retry the operation. To unassign the VA using RACADM, run the following command "racadm setpciecfg".
IOV015 Message Unable to map/un-map or turn on the external shared adapter because the firmware version of Chassis Management Controller (CMC) Chassis Infrastructure Mainboard is not the latest version supporting the adapter. Detailed Description The external shared adapter cannot be turned on until the Chassis Infrastructure firmware is updated to the latest version supporting the shared adapter.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV1001 Message The requested operation was successfully executed. Detailed Description The requested operation was successfully executed. Recommended Response Action No response action is required. Category Configuration (IOV = IO Virtualization) Severity Severity 3 (Informational) No alerts are applicable for this message IOV1002 Message The operation was not successful.
No alerts are applicable for this message IOV1004 Message Too many slots provided as parameters to Assign and UnAssign Servers methods. Detailed Description The parameters for the method identified in the message are not passed correctly. Recommended Response Action Refer to the DCIM Chassis PCI Management Profile document and provide the required parameters.
IOV1007 Message Unable to assign a PCIe slot. Detailed Description The IOV slot management subsystem detected an error which may prevent the physical assignment/unassignment or turning off of a PCIe slot. The errors can be caused by PCIe training timeouts, false hot plug signals,or installation of an unsupported PCIe adapter card. For a list of supported PCIe adapter cards contact your service provider.
IOV101 Message A PCIe adapter arg1 is inserted in arg2 arg3 . Arguments arg1 = device name, arg2 = slot type, arg3 = slot number Detailed Description The Chassis Management Controller (CMC) detected the insertion of an adapter in the slot identified in the message. Recommended Response Action If the adapter in slot identified in the message is mapped to a server, the server must be turned off then back on before server can access adapter.
Filter Visibility iDRAC ✔ CMC ✔ LC Log IPMI Alert LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔ ✔* IOV103 Message A PCIe adapter arg1 in arg2 arg3 is replaced by PCIe adapter arg4 .
Recommended Response Action Using the Chassis Management Controller (CMC) RACADM command line interface, run the command "racadm config -g cfgChassisPower -o cfgChassisPowerCap " to increase the power cap or add an additional power supply.
LC Log LCD OS Log ✔* ✔* ✔ Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* IOV106 Message Unable to power on PCIe adapter arg1 in arg2 arg3 . Arguments arg1 = device name, arg2 = slot type, arg3 = slot number Detailed Description The Chassis Management Controller (CMC) is unable to power on adapter. Possible reasons for power failures are: 1) Adapter not an approved adapter.
Filter Visibility iDRAC ✔ CMC ✔ IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔* ✔* ✔ Power Off Power Cycle LC Log LCD OS Log ✔* ✔* ✔ Reset Chassis Event Proxy iDRAC CMC ✔* IOV108 Message Power fault detected on PCIE adapter arg1 in arg2 arg3 . Arguments arg1 = device name, arg2 = slot type, arg3 = slot number Detailed Description The Chassis Management Controller (CMC) detected a power fault in an adapter after the adapter was powered on.
Category System Health (IOV = IO Virtualization) Severity Severity 3 (Informational) Filter Visibility iDRAC ✔ CMC ✔ LC Log IPMI Alert LCD SNMP Alert OS Log Email Alert Power Off Remote System Log WS Eventing ✔ ✔ Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔* IOV110 Message Successfully updated Chassis Infrastructure firmware. Detailed Description Successfully updated Chassis Infrastructure firmware. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2553 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* IOV112 Message Chassis Infrastructure firmware is not valid. Detailed Description Chassis infrastructure firmware is not valid and must be reinstalled.
Recommended Response Action No response action is required. Category System Health (IOV = IO Virtualization) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle ✔* ✔* WS Eventing iDRAC CMC ✔ Reset Chassis Event Proxy iDRAC CMC ✔* IOV114 Message arg1 arg2 assigned to server- arg3 .
Arguments arg1 = number of watts Detailed Description The discovery process for PCIE adapters was unable to allocate the power required to power on the PCIE adapters Recommended Response Action Using the Chassis Management Controller (CMC) RACADM command line interface, run the command "racadm config -g cfgChassisPower -o cfgChassisPowerCap " to increase the power cap or add an additional power supply.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔ ✔* IOV117 Message arg1 arg2 was unassigned/unmapped from server- arg3 . Arguments arg1 = "PCIE Slot" or "PERC VA", arg2 = slot number or VA number, arg3 = server number Detailed Description The PCIE Slot or PERC Virtual Adapter(VA) identified in the message has been unassigned/unmapped from the server identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC ✔ LC Log LCD Remote System Log WS Eventing ✔ ✔ ✔* ✔* ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔ ✔* IOV119 Message PCIe ride-through mode is disabled. Detailed Description The Chassis Management Controller (CMC) has disabled PCIe ride-through mode. PCIe adapters that are turned on and in "ride-through" mode are immediately turned off.
Severity Severity 3 (Informational) Trap/EventID 10747 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC ✔ LC Log LCD Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔ ✔* IOV121 Message PCIe ride-through time out has changed from arg1 to arg2 seconds.
Arguments arg1 = "PCIE Slot" or "PERC VA", arg2 = slot number or VA number, arg3 = server number Detailed Description The PCIE Slot or PERC Virtual Adapter (VA) identified in the message has been assigned to the extension of the server slot identified in the message. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔ ✔* IOV124 Message The PCIe shared adapter in slot arg1 is not supported because the firmware version of the Chassis Infrastructure Mainboard is not the latest. Arguments arg1 = slot number Detailed Description The PCIe shared adapter in slot identified in the message is not supported because the firmware version of Chassis Management Controller (CMC) Chassis Infrastructure Mainboard is not the latest.
select the Power On Server option. If the issue persists, contact your service provider.
IPA Event Messages IPA0001 Message Invalid NIC IP address parameter specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter the valid IP Address. Category Audit (IPA = DRAC IP Address) Severity Severity 2 (Warning) No alerts are applicable for this message IPA0002 Message Invalid IP address specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter a valid IP Address.
IPA0004 Message Invalid gateway address specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter the appropriate gateway. Category Audit (IPA = DRAC IP Address) Severity Severity 2 (Warning) No alerts are applicable for this message IPA0100 Message The iDRAC IP Address changed from arg1 to arg2 .
ISM Event Messages 27 ISM0000 Message The iDRAC Service Module is started on the operating system (OS) of server. Detailed Description The iDRAC Service Module is started on the OS of server. Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0001 Message The iDRAC Service Module detected a OS to iDRAC Pass-through in the arg1 mode.
operation is done only for the first run of iDRAC Service Module. If OS to iDRAC Pass-through is disabled after this point of time, iDRAC Service Module will not be able to connect to iDRAC until user enables the OS-iDRAC Pass-through in the USB mode. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0006 Message The iDRAC Service Module is unable to communicate with iDRAC using the OS to iDRAC Pass-through channel. Detailed Description The iDRAC Service Module could not successfully communicate with iDRAC, because the OS to iDRAC Pass-through channel is not configured in the USB-NIC mode.
ISM0008 Message Some features of iDRAC Service Module will be disabled on this server, because OpenManage Server Administrator is running on the operating system (OS) of this server. Detailed Description iDRAC Service Module detected that OpenManage Server Administrator is running on the OS of this server. Therefore, one or more features of iDRAC Service Module will be disabled. Recommended Response Action End the OpenManage Server Administrator session.
enable the module by using RACADM command, run the following command at the command line interface: racadm set idrac.servicemodule.ServiceModuleEnable enabled Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0011 Message The server operating system (OS) is unable to start the iDRAC Service Module, because it is set to "disabled" in iDRAC.
Detailed Description The feature identified in the message is enabled by using the one of the iDRAC interfaces. Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0014 Message The feature arg1 is disabled. Arguments arg1 = feature name Detailed Description The feature identified in the message is disabled by using one of the iDRAC interfaces.
Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0017 Message The BMC watchdog auto-recovery action is changed from arg1 to arg2 . Arguments arg1 = original action, arg2 = new action Detailed Description The BMC watchdog auto-recovery action is changed from the original action identified in the message to the new action identified in the message.
Category Audit (ISM = iDRAC Service Module) Severity Severity 2 (Warning) No alerts are applicable for this message ISM0020 Message The OS Collector application did not start successfully on the server operating system (OS) because the iDRAC emulated USB device with the OS Collector application was not found.
Category Audit (ISM = iDRAC Service Module) Severity Severity 2 (Warning) No alerts are applicable for this message ISM0023 Message The feature WMI Information is de-activated because the iDRAC firmware version installed is not compatible. It will be activated when the compatible iDRAC firmware is installed. Detailed Description The feature WMI Information is disabled. It will be enabled when a compatible iDRAC firmware is installed.
28 JCP Event Messages JCP000 Message A new job with ID arg1 is created. Arguments arg1 = ID number Detailed Description A new job with the ID identified in the message is created. Recommended Response Action No response action is required.
JCP002 Message Unable to schedule the job. Detailed Description The Lifecycle Controller is not able to schedule a job at this time because of an internal error. Recommended Response Action Wait up to three minutes and retry the operation. If the problem persists, reboot the system and enumerate DCIM_Lifeycle Job to view the list of jobs that are currently scheduled.
Detailed Description System services was cancelled by selecting CTRL+E on boot up and cancelling it through the iDRAC configuration utility. This prevents jobs from executing further. Recommended Response Action Enable system services through the CTRL+E on boot up on the target system through the iDRAC configuration utility. Category Configuration (JCP = Job Control) Severity Severity 3 (Informational) No alerts are applicable for this message JCP006 Message Invalid job attribute.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC JCP008 Message Job completed with errors. Detailed Description Multiple attributes were set in the operation but some set attribute actions were not successful.
Severity Severity 3 (Informational) No alerts are applicable for this message JCP010 Message The command was successful. Detailed Description The method invoked was successfully completed. Recommended Response Action No response action is required. Category Configuration (JCP = Job Control) Severity Severity 3 (Informational) No alerts are applicable for this message JCP011 Message Invalid parameter value for arg1 .
JCP013 Message Missing parameter(s) arg1 Arguments arg1 = parameters Detailed Description One or more required input parameters needed for the operation are missing. Recommended Response Action Refer to the documentation for the operation being attempted and provide valid values for the identified parameters. Category Configuration (JCP = Job Control) Severity Severity 2 (Warning) No alerts are applicable for this message JCP014 Message Maximum jobs per queue exceeded.
No alerts are applicable for this message JCP016 Message Invalid UntilTime value. A minimum of 5 minutes is required. Detailed Description The UntilTime input parameter for the job or job queue creation must be at least 5 minutes after the value specified in the StartTime parameter. Recommended Response Action Set the UntilTime at least 5 minutes after StartTime and retry the operation.
No alerts are applicable for this message JCP019 Message Cannot create new jobs until the existing Import System Profile job is completed or cancelled. Detailed Description A new job cannot be created until the existing Import Server Profile job is complete or deleted. Only one Import Server Profile job can be running at any given time. Recommended Response Action Do one of the following: 1) Retry the operation after the Import Server Profile job is complete.
JCP022 Message Invalid Job ID arg1 for scheduling or deletion operation. Arguments arg1 = jobid number Detailed Description An invalid Job ID was provided as input for a scheduling or deletion operation. The Job ID indicated in the message does not match an existing Job on the target system. Recommended Response Action Verify the job ID value by enumerating job instances and validating that the Job ID value is correct for the job being scheduled or deleted.
JCP025 Message Lifecycle Controller is not enabled. Detailed Description Lifecycle Controller must be enabled to perform the requested operation. Lifecycle Controller can be enabled in the F2 Setup application or through a remote operation. Recommended Response Action If Lifecycle Controller is in Recovery mode a firmware update of Lifecycle Controller may be required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔* OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC JCP028 Message Job status updated. Detailed Description An install or configuration job status is successfully updated on iDRAC. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC JCP030 Message Unable to schedule jobs while an iDRAC firmware update or configuration job is running. Detailed Description Unable to schedule jobs for execution while an iDRAC firmware update job is running. Recommended Response Action Wait for the running job to complete, and then retry the operation.
Recommended Response Action Make sure that only one of either -r or --realtime option is entered. For example, to run a job immediately, enter the --realtime option. To schedule a job that will be run after restarting a server, use the -r option. For more information about options, see the RACADM Command Line Reference Guide available at the support site. If the issue persists, contact your service provider.
LC Event Messages 29 LC001 Message Command successful. Detailed Description The command completed successfully. Recommended Response Action No response action is required. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC002 Message General failure. Detailed Description A general failure occurred while executing the command. Recommended Response Action Verify network connectivity.
No alerts are applicable for this message LC004 Message Provisioning Server information is not formatted correctly. Detailed Description The Provisioning Server parameter information is not formatted correctly. Recommended Response Action Verify the string format. Enter a valid IP address or hostname for the Provisioning Server such as: 1) hostname 2) hostname.domain.com 3) 1.1.1.1 4) hostname:8080 5) hostname.dell.
LC007 Message Invalid Parameter. Detailed Description One of the parameters specified in the method is invalid. Recommended Response Action Verify that the parameters specified are correct. For a list of parameters for this method refer to the Lifecycle Controller User Guide. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC008 Message Unsupported method parameter value.
Detailed Description The communications encryption certificate was imported successfully. Recommended Response Action No response action is required. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC0100 Message Lifecycle Controller has entered Recovery mode. Detailed Description A persistent error has occurred while carrying out a Lifecycle Controller operation.
Category Configuration (LC = Lifecycle Contr) Severity Severity 1 (Critical) No alerts are applicable for this message LC012 Message Another process is using Lifecycle Controller. Detailed Description Lifecycle Controller is in use by another process. Wait for other process to complete before attempting to run another command. Recommended Response Action Try one of the following: 1) Rerun the command after about 2 minutes.
No alerts are applicable for this message LC015 Message Invalid Part Configuration Update Detailed Description Invalid current attribute value Recommended Response Action Check for correct parameter values: 1) Disabled 2) Apply always 3) Apply only if firmware match. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC016 Message Missing required parameter, arg1 .
LC018 Message Server certificate successfully modified. iDRAC will now restart and be unavailable during restart. Detailed Description The certificate modification operation was successful. Communication to iDRAC will be lost as iDRAC restarts to use the new server certificate. Recommended Response Action No response action is required.
Detailed Description The contents of the PKCS12 parameter was not valid because: 1) not a valid PKCS12 file 2) not a valid pfx file 3) did not contain a valid key. Recommended Response Action Validate that the PKCS12 file was Base64 encoded. OpenSSL can be used to create or validate a PKCS12 file. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC022 Message Lifecycle Controller Log Export was successful.
Category Configuration (LC = Lifecycle Contr) Severity Severity 1 (Critical) No alerts are applicable for this message LC025 Message Insufficient space on network share. Detailed Description Insufficient space on network share. Recommended Response Action Make more space available on the network share and try the operation again.
LC028 Message Unable to retrieve Hardware Inventory information. Detailed Description Hardware Inventory information is not retrievable due to an internal error. Recommended Response Action Try one of the following: 1) Try the operation again 2) AC power cycle system 3) apply the latest firmware update packages for Lifecycle Controller and iDRAC.
Detailed Description An internal error occurred while exporting the Hardware Inventory XML file. Recommended Response Action Reset iDRAC and retry the command. Category Configuration (LC = Lifecycle Contr) Severity Severity 1 (Critical) No alerts are applicable for this message LC032 Message The Hardware Inventory Export method not supported. Detailed Description This method is not supported in the current version of iDRAC firmware.
Severity Severity 3 (Informational) No alerts are applicable for this message LC035 Message As-Shipped Hardware Inventory Export method is not supported. Detailed Description This method is not supported in this version of Firmware. Recommended Response Action Update the iDRAC firmware to a version that supports this method.
LC038 Message An instance of Hardware Inventory export is already in progress. Detailed Description Lifecycle Controller is locked by another instance of the Hardware Inventory export process. Allow the process to complete before attempting another export operation. Recommended Response Action Do one of the following: 1) Rerun the command after about 2 minutes 2) Reset the iDRAC and rerun the command.
Detailed Description The length of the Console name exceeds the maximum length allowed or the file operation error encountered. Recommended Response Action Change the name of a console to a name less than 32 characters. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC042 Message Configure Console name in FlexAddr mode Detailed Description Configure Console name while Virtual Address Management is in FlexAddr mode.
Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC045 Message An instance of CreateConfigJob is already running. Detailed Description The CreateConfigJob operation is currently running. The current operation and system restart must complete before the operation can be attempted again. Recommended Response Action Wait for the CreateConfigJob operation that is currently running to complete before requesting another operation.
LC048 Message Invalid input value for IPChangeNotifyPS. Detailed Description The value provided to set the attribute identified in the message is invalid. Recommended Response Action For more information on the valid values, see Lifecycle Controller-Remote Services documentation. Retry the operation with a valid value for the IPChangeNotifyPS attribute.
LC051 Message Cannot create multiple Server Profile Export jobs. Detailed Description There can only be one Server Profile Export job at a time. Recommended Response Action Wait for the existing Server Profile Export job to run and complete or cancel it, before retrying the operation. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC052 Message Cannot create multiple Server Profile Import jobs.
Detailed Description The network share may be read-only or it may not have sufficient space for the export operation. Recommended Response Action Verify the network share is not read-only and has sufficient space for exporting, then retry the operation. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC055 Message The operation did not complete successfully because of an invalid attribute array.
Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC058 Message Invalid AttributeValue parameter value for corresponding AttributeName value, arg1 . Arguments arg1 = AttributeName Detailed Description The attribute value specified in the AttributeValue array is not valid for the corresponding specified attribute.
No alerts are applicable for this message LC061 Message Lifecycle controller is ready to take provisioning requests Detailed Description Jobs, invoke methods, enumerates can now be performed on Lifecycle controller. Lifecycle controller is ready to take provisioning requests. Recommended Response Action No response action is required.
Arguments arg1 = max parameter length, arg2 = parameter name Detailed Description The maximum number of characters allowed for the parameter is displayed. Recommended Response Action Reduce the number of characters to the maximum length allowed for this parameter. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC065 Message The iDRAC static IP address information is not fully configured.
Detailed Description The Export Certification operation successfully exported the SSL Certificate. Recommended Response Action No response action is required. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC068 Message Unable to perform the import or export operation because there are pending attribute changes or a configuration job is in progress.
Recommended Response Action Make sure the input configuration XML file for the operation exists on the network share. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC071 Message The Lifecycle Controller version does not support the export or import of the Server Configuration XML file.
Severity Severity 3 (Informational) No alerts are applicable for this message LC074 Message The Certificate export operation did not complete successfully. Detailed Description The Certificate export operation did not complete successfully. Recommended Response Action Retry the operation. If the issue persists, restart the iDRAC and retry the operation.
LC077 Message Certificate imported successfully. Reset iDRAC to apply new certificate. Until iDRAC is reset old certificate will be active Detailed Description The new certificate will not be in-use until iDRAC has been restarted Recommended Response Action No response action is required.
LIC Event Messages 30 LIC000 Message The License Manager action succeeded. Detailed Description This command was successful. Recommended Response Action No response action is required. Category Audit (LIC = Licensing) Severity Severity 3 (Informational) No alerts are applicable for this message LIC001 Message The License Manager command parameter used is invalid. Detailed Description The command or command parameters passed to License Manager is invalid.
Recommended Response Action If the firmware has been rolled back to a previous version, this error may occur. All previously installed licenses must be re-imported. If this is not the case, contact technical support. Category Audit (LIC = Licensing) Severity Severity 1 (Critical) No alerts are applicable for this message LIC003 Message License Manager was unable to create and/or allocate the required resources. Detailed Description System resources may be unavailable at the time command is issued.
Detailed Description The maximum number of installed licenses has been reached. Recommended Response Action Delete one of the currently installed licenses and retry the import. Category Audit (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC006 Message The license has expired. Detailed Description The license end date has been reached. Recommended Response Action Obtain a replacement license and import it.
Recommended Response Action Obtain a new license file with the correct unique identifier for the device. To use this license, import to the device with the correct unique identifier. Category Audit (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC009 Message The license upgrade was unsuccessful. Detailed Description An upgrade license carries specific information about the license it is replacing.
Severity Severity 2 (Warning) No alerts are applicable for this message LIC012 Message The license file does not exist. Detailed Description This error may occur if: 1) The license was deleted by another user. 2) The license that is being imported may have been deleted from the temporary storage before the import operation completed. 3) At start-up, License Manager does not find the license assigned to the device. This may occur if a power outage occurs before a license delete operation completes.
Severity Severity 2 (Warning) No alerts are applicable for this message LIC015 Message The License Manager database restore operation failed. Detailed Description This error occurs when the Lifecycle Controller restore operation is interrupted before it completes. This can occur due to a power outage or when a system is rebooted before the operation is completed. Recommended Response Action Repeat the Lifecycle Controller restore operation. If the problem persists, contact technical support.
LIC018 Message The license is already imported. Detailed Description The license is already imported on the system and does not need to be reimported. Recommended Response Action No response action is required. Category Audit (LIC = Licensing) Severity Severity 3 (Informational) No alerts are applicable for this message LIC019 Message A leased license may not be imported prior to its start date.
Detailed Description All the features in the evaluation license are currently licensed in the system. The license is not imported as it would duplicate existing and active licensed features. Recommended Response Action Remove the license(s) that contain the license set from the evaluation license. Category Audit (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC022 Message License Manager database locked due to ongoing backup and restore operation.
Recommended Response Action Purchase a new license to prevent interruption of licensed features. Category Audit (LIC = Licensing) Severity Severity 2 (Warning) Trap/EventID 8514 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔* ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔* CMC LIC202 Message A system error was detected during License Manager startup.
Arguments arg1 = entitlement ID Detailed Description Signature verification failed due to an error in the saved license file. Recommended Response Action Delete and re-import the license file.
LIC205 Message License Manager database lock timeout has been exceeded. Detailed Description The License Manager sets a maximum time period that its database may be locked. If that timeout exceeds, it releases the lock conditions and reports the error. The user must assume that the Lifecycle Controller backup or restore operation failed and should repeat the operation. Recommended Response Action Repeat the backup or restore operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* LIC207 Message License arg1 on device arg2 has expired. Arguments arg1 = entitlement ID, arg2 = device name Detailed Description The license has expired. This could result in the loss of functionality that is specific to the features supported by the license. Recommended Response Action Obtain and import a replacement license.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔* ✔ ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* LIC209 Message License arg1 exported from device arg2 successfully. Arguments arg1 = entitlement ID, arg2 = device name Detailed Description A license was successfully exported. Recommended Response Action No response action is required.
Category Audit (LIC = Licensing) Severity Severity 3 (Informational) Trap/EventID 8515 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔* ✔ ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* LIC211 Message The iDRAC feature set has changed. Detailed Description License import/delete/expiration resulted in a feature set change.
Recommended Response Action No response action is required. Category Audit (LIC = Licensing) Severity Severity 3 (Informational) Trap/EventID 8515 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* LIC213 Message A system error was detected during License Manager startup.
Detailed Description The attempted action requires a valid license for certain advanced features installed in the system but the required license is missing or expired. Recommended Response Action Obtain an appropriate license then try again. If the problem persists, contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Detailed Description The operation was successful. Recommended Response Action No response action is required. Category Configuration (LIC = Licensing) Severity Severity 3 (Informational) No alerts are applicable for this message LIC901 Message Invalid parameter value for arg1 . Arguments arg1 = parameter Detailed Description The value provided for the specified parameter is invalid.
Recommended Response Action To provide the correct parameters, see Lifecycle Controller-Remote Services documentation. Category Configuration (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC904 Message Could not connect to network share. Detailed Description The network share is not accessible from the iDRAC. Recommended Response Action Verify the network share connection and retry the operation.
LIC907 Message Unable to perform the operation due to an unknown error in iDRAC. Detailed Description The operation did not complete successfully because of lack of an unknown error in the iDRAC. Recommended Response Action Retry the operation. If the issue persists, reset the iDRAC.
31 LNK Event Messages LNK0001 Message Network share name unavailable. Detailed Description The entered network share name is not valid. Recommended Response Action Enter a valid network share name and retry the operation. For more information, see Lifecycle Controller Users Guide.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC LNK0003 Message Unable to connect to the DNS server. Detailed Description Cannot connect to the DNS server because of network issues or there is no response from the DNS server. Recommended Response Action Verify that the server is connected to the network and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC LNK0005 Message Unable to connect to DHCP server. Detailed Description Error occurred while communicating with the DHCP server because the network settings are not configured correctly or the DHCP server could not be contacted.
Severity Severity 1 (Critical) Trap/EventID 2249 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* LNK2701 Message The arg1 network link is up. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Detailed Description The server identified in the message could not be successfully connected to the external network, because the network connection is not functional. Recommended Response Action Do one of the following, and then retry the operation: 1) Check whether or not the external network cable is functioning. 2) Reinstall or replace network cable of the IOM and port identified in the message.
LOG Event Messages 32 LOG001 Message Missing required InstanceID or JobID parameter. Detailed Description One or more required parameters needed for the method invoked in the operation are missing. Recommended Response Action To provide the correct value for the specified parameter, see Lifecycle ControllerRemote Services documentation.
No alerts are applicable for this message LOG004 Message Resource allocation failure. Detailed Description The operation did not complete successfully because of lack of memory or file space in iDRAC firmware. Recommended Response Action Reset iDRAC and retry the operation. Category Configuration (LOG = Log event) Severity Severity 1 (Critical) No alerts are applicable for this message LOG005 Message Cannot perform the operation due to an unknown error in iDRAC.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC LOG007 Message The previous log entry was repeated arg1 times. Arguments arg1 = log entry count Detailed Description This message is generated after a series of sequential duplicate events. Log entry count is the number of times the previous message was repeated.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC LOG201 Message Recovered from Lifecycle Controller Log corruption. Detailed Description Lifecycle Controller Log corruption was detected during iDRAC boot. The Lifecycle Controller Log was truncated at the point of corruption. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Audit (LOG = Log event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC LOG204 Message Lifecycle Log archive operation did not complete. Detailed Description The archive operation did not complete.
Recommended Response Action No response action is required. Category Configuration (LOG = Log event) Severity Severity 3 (Informational) No alerts are applicable for this message LOG302 Message The Chassis Log file header is corrupted. Detailed Description The Chassis Log file header is corrupted. The Chassis Log will be recreated and all current log entries will not be preserved. Recommended Response Action No response action is required.
LOG320 Message Log monitoring is disabled. Log type: arg1 . Arguments arg1 = log type Detailed Description The hardware log in the system is disabled. The log type information is provided. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC LOG322 Message The log size is no longer near the maximum capacity. Log type: arg1 . Arguments arg1 = log type Detailed Description The hardware log in the system is no longer near its maximum capacity. The log type information is provided. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 5553 IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC LOG324 Message The log size has reached its maximum capacity. Log type: arg1 . Arguments arg1 = log type Detailed Description The size of a hardware log in the system has reached its maximum capacity. The log type information is provided.
Detailed Description Unable to receive any log entries, and therefore log status cannot be monitored. The log type information is provided. Recommended Response Action Make sure that iDRAC is functioning correctly.
Detailed Description An Alert Log backup was created. Recommended Response Action No response action is required. Category Audit (LOG = Log event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC LOG328 Message The Server Based Management Mode is enabled. Detailed Description The Server Based Management Mode is enabled.
Detailed Description The Server Based Management Mode is disabled. Chassis based PSUs, fans, and sensor information will not be displayed from server based system management tools. Recommended Response Action No response action is required.
No alerts are applicable for this message LOG503 Message Unable to run the method because the parameter arg1 is not valid. Arguments arg1 = parameter Detailed Description The command cannot be run because the value of the parameter identified in the message is not valid. Recommended Response Action Enter all the parameters required in the command as per the enumeration, and then retry the operation. For more information, see the Chassis Record Log Profile.
LOG506 Message Unable to start the requested operation because the ExportChassisLog operation is already running. Detailed Description The requested operation cannot be started because the ExportChassisLog operation is already running. Recommended Response Action Wait for the current ExportChassisLog operation to complete and then retry the operation. If the issue persists, contact your service provider.
Arguments arg1 = parameter name, arg2 = max parameter length Detailed Description The command cannot be run because the value of the parameter identified in the message exceeds the maximum length identified in the message. Recommended Response Action Enter a value for the parameter identified in the message that is equal to or less than the maximum allowed characters.
33 MEM Event Messages MEM0000 Message Persistent correctable memory errors detected on a memory device at location(s) arg1 . Arguments arg1 = location Detailed Description The memory is operational. This is an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Multi-bit memory error on . Reseat memory Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0002 Message Parity memory errors detected on a memory device at location arg1 . Arguments arg1 = location Detailed Description The memory is operational.
Arguments arg1 = location Detailed Description The memory is operational. This is an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM0005 Message Persistent correctable memory error limit reached for a memory device at location(s) arg1 . Arguments arg1 = location Detailed Description The memory is operational. This is an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem persists, contact technical support.
Trap/EventID Filter Visibility iDRAC 2267 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0007 Message Unsupported memory configuration; check memory device at location arg1 . Arguments arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Detailed Description None Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0009 Message Memory device at location arg1 is throttled.
MEM0010 Message Memory device at location arg1 is overheating. Arguments arg1 = location Detailed Description System performance is degraded. Recommended Response Action If unexpected, review system logs for power or thermal exceptions. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory device is over heating.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM0020 Message Memory device at location arg1 is enabled. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0022 Message Memory device at location arg1 is absent. Arguments arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced. Recommended Response Action If unexpected, check presence, then re-install.
Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0600 Message Memory device was added at location arg1 . Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Detailed Description None Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC MEM0700 Message The persistent correctable memory error rate is at normal levels for a memory device at location arg1 .
MEM0701 Message Correctable memory error rate exceeded for arg1 . Arguments arg1 = location Detailed Description The memory may not be operational. This an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem continues, contact support.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM1000 Message Memory device at location arg1 transition to a running state. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC MEM1002 Message Memory device at location arg1 is in test. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Category System Health (MEM = Memory) Severity Severity 2 (Warning) Trap/EventID 2266 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1004 Message Memory device at location arg1 is powered off. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Detailed Description None Recommended Response Action Re-attempt memory removal process Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1006 Message Memory device at location arg1 is online.
MEM1007 Message Memory device at location arg1 failed to transition to online.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM1009 Message Memory device at location arg1 failed to transition to offline.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1011 Message Memory device at location arg1 is on-duty. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Category System Health (MEM = Memory) Severity Severity 2 (Warning) Trap/EventID 2266 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1013 Message Memory device at location arg1 is in a full state. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Detailed Description None Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1015 Message Memory device at location arg1 is in a power active state.
MEM1016 Message Memory device at location arg1 is not installed correctly. Arguments arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced. Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory is not installed correctly.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM1200 Message Memory RAID is redundant. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1202 Message Memory RAID redundancy is degraded. Check memory device at location(s) arg1 . Arguments arg1 = location Detailed Description None Recommended Response Action Re-install the memory component. If the problem continues, contact support.
Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1204 Message Memory mirror is redundant. Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Review system logs for memory exceptions. Re-install memory at location Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory mirror lost on .
MEM1207 Message Memory spare is redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1208 Message Memory spare redundancy is lost.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM1209 Message Memory spare redundancy is degraded. Check memory device at location arg1 . Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC MEM1212 Message Memory redundancy is lost. Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Recommended Response Action Review system logs for memory exceptions.
Trap/EventID Filter Visibility iDRAC 2266 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM6000 Message Memory device monitoring is disabled. Detailed Description The memory module may not be correctly seated, wrongly configured, or has failed. Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions. Reinstall the memory modules.
Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions. Reinstall the memory modules at the identified location . Category System Health (MEM = Memory) Severity Severity 2 (Warning) OMSA Event ID 5401 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC MEM6002 Message Memory device status is normal.
MEM6003 Message Memory device status is non-critical. Memory device location: arg1 , Possible memory module event cause: arg2 . Arguments arg1 = location, arg2 = cause Detailed Description The memory module may not be correctly seated, wrongly configured, or has failed. Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions. Reinstall the memory modules at the identified location .
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC MEM6005 Message Memory device has failed. Memory device location: arg1 , Possible memory module event cause: arg2 . Arguments arg1 = location, arg2 = cause Detailed Description The memory module failed because of an irrecoverable error.
Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM7002 Message A hardware mismatch detected for memory riser.
MEM8000 Message Correctable memory error logging disabled for a memory device at location arg1 . Arguments arg1 = location Detailed Description Errors are being corrected but no longer logged. Recommended Response Action Review system logs for memory exceptions. Re-install memory at location Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message SBE log disabled on .
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC MEM8500 Message Low memory condition detected. Detailed Description A low memory condition was detected. If this condition continues, a failover or a reset may occur. If multiple resets occur, contact your service provider. Recommended Response Action If multiple resets occur, contact Service.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* MEM8502 Message ECC Memory error rate failover condition detected. Detailed Description An ECC memory condition was detected on the primary CMC and a failover was initiated. Recommended Response Action Reseat the primary CMC and initiate a failover back to the primary CMC. If the problem persists and multiple failovers occur, contact your service provider. .
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔ ✔ OS Log Power Off Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD ✔* Power Cycle Reset Chassis Event Proxy ✔ CMC MEM9001 Message Memory interconnect is functioning normally. Detailed Description The memory interconnect is functioning normally. Recommended Response Action No response action is required.
Category System Health (MEM = Memory) Severity Severity 2 (Warning) Trap/EventID 2266 LCD Message Intel QPI interconnect has a correctable error. Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔ ✔ OS Log Power Off Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD ✔* Power Cycle Reset Chassis Event Proxy ✔ CMC MEM9003 Message Intel SMI 2 Memory interconnect arg1 has a correctable error.
MEM9004 Message Intel QPI interconnect arg1 has degraded. Arguments arg1 = QPI link number Detailed Description A link degradation was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message. The system will continue to operate at reduced performance. Recommended Response Action Do one of the following: 1) Restart the server and check whether the issue persists.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔ ✔ OS Log Power Off Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD ✔* Power Cycle Reset Chassis Event Proxy ✔ CMC MEM9006 Message Intel QPI interconnect arg1 has a non-recoverable issue. Arguments arg1 = QPI link number Detailed Description A non-recoverable link issue was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message.
Detailed Description A non-recoverable link issue was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message. Recommended Response Action Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, contact your service provider.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM9009 Message Intel DDR Memory interconnect arg1 has a correctable error. Arguments arg1 = link number Detailed Description A correctable error was detected in the propagation of signals on the Intel DDR memory interconnect identified in the message. Recommended Response Action Do the following: 1) Reseat all DIMMs on the memory riser, 2) Reseat the memory riser, and 3) Restart the server.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC MEM9015 Message Multi-bit memory errors detected on a Dual In-line Memory Module (DIMM) device arg1 . Arguments arg1 = location Detailed Description The memory device identified in the message has encountered a uncorrectable error. System performance may be degraded.
Detailed Description The memory device identified in the message may not be operational. This an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component identified in the message. If the issue persists, contact your service provider. Refer to the product documentation to choose a convenient contact method.
NIC Event Messages 34 NIC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
NIC004 Message Invalid parameter value for arg1 Arguments arg1 = attribute name Detailed Description The value for the specified parameter is invalid. Recommended Response Action Verify that parameter values passed to the method are entered as they appear in the enumeration and parameter data type matches the documentation.
NIC007 Message A configuration job already exists, Cannot create another configuration job on specified target until existing job is completed or is cancelled Detailed Description A configuration job already exists for the specified target. No further configuration operation is allowed until the existing job completes or the job is cancelled.
NIC010 Message Lifecycle Controller is not enabled, cannot create Configuration job. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle Controller must be enabled to perform the requested operation.
NIC013 Message Invalid AttributeName: arg1 Arguments arg1 = attribute name Detailed Description An unknown AttributeName was entered for the operation. Recommended Response Action Enter the correct AttributeName available in the system. Refer to the enumeration response for desired attribute.
NIC016 Message AttributeValue cannot be changed for disabled AttributeName arg1 . Arguments arg1 = attribute name Detailed Description A set attribute operation was attempted on a disabled attribute. Recommended Response Action No response action is required.
Detailed Description The old BIOS password used to change the password is incorrect. Recommended Response Action Enter the correct old password for the BIOS and retry the operation. Category Configuration (NIC = NIC Config) Severity Severity 2 (Warning) No alerts are applicable for this message NIC022 Message Unable to set the BIOS password because of a jumper setting on the motherboard. Detailed Description The current BIOS password jumper setting prevents the BIOS password from being changed.
Severity Severity 2 (Warning) No alerts are applicable for this message NIC100 Message The NIC arg1 Port arg2 network link is down. Arguments arg1 = Controller, arg2 = Port Detailed Description The network link is down. Either the network cable is not connected or the network device is not working. Recommended Response Action Verify that the network port is enabled and if the port has Activity/Speed LEDs, that they are lit.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC ✔* LCD Reset Chassis Event Proxy ✔ CMC NIC500 Message The requested object is not allowed to be configured if DHCP is enabled. Detailed Description The values of IP Address is not allowed to change if DHCP is enabled. Recommended Response Action Disable DHCP and then modify the value.
Recommended Response Action Enable DHCP on the NIC before enabling it for DNS. Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC503 Message The DNS server IP address is not allowed to be configured if DNS server DHCP (cfgDNSServersFromDHCP) is enabled. Detailed Description The value of the specified parameter cannot be changed. Recommended Response Action Disable the cfgDNSServersFromDHCP object.
Severity Severity 3 (Informational) No alerts are applicable for this message NIC506 Message The requested object requires DNS registration to be enabled. Detailed Description The requested operation requires the DNS registration to be enabled. Recommended Response Action Enable the DNS registration. Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC507 Message Unable to determine current NIC state.
NIC509 Message NIC is now ENABLED Detailed Description Success message. Recommended Response Action No response action is required. Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC510 Message NIC is now DISABLED Detailed Description Success message. Recommended Response Action No response action is required.
Detailed Description Success message. Recommended Response Action No response action is required. Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC513 Message DHCP6 is already ENABLED Detailed Description Success message. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) No alerts are applicable for this message NIC516 Message Static IP configuration enabled and modified successfully Detailed Description Success message. Recommended Response Action No response action is required.
35 OSD Event Messages OSD062 Message The process of installing an operating system or hypervisor is started and is in progress. Detailed Description The process of installing an operating system or hypervisor is started and is in progress. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert ✔ ✔ LCD OS Log Email Alert Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC ✔ Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC OSD064 Message The process of installing an operating system or hypervisor is abruptly stopped either by the user or the installation infrastructure. Detailed Description The process of installing an operating system or hypervisor is abruptly stopped either by the user or the installation infrastructure.
Severity Severity 1 (Critical) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔ LCD OS Log Power Off Power Cycle CMC LC Log iDRAC ✔ Reset Chassis Event Proxy ✔ CMC OSD1 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Configuration (OSD = OS Deployment) Severity Severity 3 (Informational) No alerts are applicable for this message OSD12 Message Cannot create the USB device needed to copy drivers for the selected operating system. Detailed Description iDRAC was unable to create and expose the drivers as a USB device for the OS installation to proceed. Recommended Response Action 1) Rerun the command. 2) Reset iDRAC and rerun the command.
Severity Severity 1 (Critical) No alerts are applicable for this message OSD15 Message Mount network share failed - incorrect username or password. Detailed Description Unable to mount the network share using the credentials specified in the command because either the username or password is incorrect. Recommended Response Action Rerun the command with the correct username and password.
OSD18 Message Unable to locate the ISO image on the network share point. Detailed Description Unable to find the ISO file specified in the network share. Make sure that the correct ISO file path was entered into the command and that all other user credentials are correct. Recommended Response Action Rerun the command with the correct ISO file path.
Detailed Description Unable to get the size or label for selected operating system from the Driver Pack present in Lifecycle Controller. The driver pack may be corrupt. Recommended Response Action Update the Driver Pack using USC or DUP and rerun the command. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD21 Message Unable to boot to ISO image. Detailed Description Booting to ISO has failed.
Category Configuration (OSD = OS Deployment) Severity Severity 3 (Informational) No alerts are applicable for this message OSD24 Message Unable to continue with DetachDrivers - UnPackAndAttach is in progress. Detailed Description Unable to continue with DetachDrivers - UnPackAndAttach is in progress. Recommended Response Action Wait until UnpackAndAttach finishes and then run DetachDrivers. This can take more than 5 minutes.
OSD27 Message Copying drivers for selected operating system failed. Detailed Description Copying drivers for selected operating system failed. The Driver Pack may be unusable. Recommended Response Action Update the Driver Pack using USC or DUP and then rerun the command. Category Configuration (OSD = OS Deployment) Severity Severity 3 (Informational) No alerts are applicable for this message OSD28 Message Hash verification on the ISO image failed.
Detailed Description Lifecycle Controller is currently locked by another process. Make sure that the process completes before attempting to run another command. Recommended Response Action 1) After two minutes, rerun the command. 2) Make sure that USC or DUP is not currently running on the server. 3) Reset iDRAC and rerun the command.
Category Configuration (OSD = OS Deployment) Severity Severity 3 (Informational) No alerts are applicable for this message OSD33 Message Installed BIOS version does not support this method. Detailed Description The system has an older version of BIOS that does not support this method. Install the latest version of BIOS to use this method. Recommended Response Action Update the BIOS to version 1.2 or later and then rerun the command.
OSD36 Message Boot to ISO Image has been cancelled by using CTRL+E option on the server. Detailed Description User has cancelled system services by using the CTRL+E option (iDRAC configuration utility) during POST. This action cancels the WSMAN request to boot to ISO. Recommended Response Action To resolve the issue rerun the command. Do not cancel system services using CTRL+E during POST when system is rebooting to the ISO.
Detailed Description Unable to get VFlash information from internal instrumentation. Recommended Response Action 1) Make sure the Dell VFlash is seated correctly. 2) Make sure a Dell licensed VFlash card is inserted 3) Make sure the Dell VFlash doesnt have any hardware issues by accessing it through the iDRAC GUI. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD4 Message Cannot access Lifecycle Controller Driver Pack partition.
Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD42 Message Downloading ISO File to VFlash failed. Detailed Description There was an error while copying the ISO image from the network share to the VFlash. Recommended Response Action 1) Make sure the network connection is working. 2) Make sure the Dell VFlash doesnt have any hardware issues by accessing it through the iDRAC GUI.
OSD45 Message Cannot delete ISO image from VFlash. Detailed Description The ISO Image present in VFlash is attached to the host system. The ISO Image cannot be deleted from VFlash. Recommended Response Action Execute DetachISOFromVFlash() before running DeleteISOFromVFlash() Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD46 Message VFlash in use.
Detailed Description ISO Images of more than 4GB are not supported and cannot be copied to VFlash. Recommended Response Action Use an ISO that is smaller than 4GB. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD49 Message Disable RIPS mode to access VFlash. Detailed Description VFlash cannot be accessed because RIPS mode is enabled.
Severity Severity 2 (Warning) No alerts are applicable for this message OSD51 Message Reboot the system to run pending System Services Tasks. Detailed Description There are pending System Services tasks on the host system that are preventing the execution of this method. Recommended Response Action Reboot the host system. The system will automatically enter System Services and complete the pending tasks.
OSD54 Message vFlash already has 16 partitions Detailed Description vFlash allows only 16 partitions to be created Recommended Response Action Make sure that there are less than 16 partitions before creating another partition on vFlash. Category Configuration (OSD = OS Deployment) Severity Severity 3 (Informational) No alerts are applicable for this message OSD55 Message ISO Image is attached to host Detailed Description Cannot attach the ISO image since it is already attached to the host.
Detailed Description Remote File Share (RFS) is currently configured to be in auto-attach mode. For Web services to attach an ISO, RFS should be changed to attach mode. Recommended Response Action Change the Remote File Share (RFS) mode to Attach using iDRAC GUI or Remote Services API and retry. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD58 Message Unable to connect an ISO using Remote File Share (RFS).
Severity Severity 1 (Critical) No alerts are applicable for this message OSD60 Message Unable to connect to ISO using Remote File Share (RFS). Detailed Description Connecting ISO using Remote File Share (RFS) was unsuccessful. Recommended Response Action Verify ISO is connected using Remote File Share (RFS) and retry the operation.
OSD63 Message Unable to run the DetachDrivers invoke method because the driver files are not attached. Detailed Description The DetachDrivers invoke method cannot be run because the driver files are not attached. Recommended Response Action No response action required.
OSD7 Message Unable to retrieve Lifecycle Controller handle. Detailed Description Unable to connect to Lifecycle Controller because of an existing open connection or an internal error. Recommended Response Action Reset iDRAC, and rerun the command to correct the problem. Category Configuration (OSD = OS Deployment) Severity Severity 1 (Critical) No alerts are applicable for this message OSD8 Message Setting Boot to PXE through IPMI failed.
36 OSE Event Messages OSE0000 Message A critical stop occurred during OS load. Detailed Description The system halted due to an exception during operating system load or operating system initialization.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC OSE0002 Message An OS graceful stop occurred. Detailed Description (IPMI sensor type 20h - offset 02h). Recommended Response Action No response action is required.
Trap/EventID Filter Visibility iDRAC 2411 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC OSE0004 Message A soft shut-down initiated by platform event filter. Detailed Description A separate exception or status condition shutdown the operating system. (IPMI sensor type 20h - offset 04h).
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1000 Message A: boot completed. Detailed Description The system OS has successfully booted from A: Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1002 Message C: boot completed. Detailed Description The system OS has successfully booted from C: Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC OSE1004 Message PXE boot completed. Detailed Description The system OS has successfully booted from the PXE server. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC OSE1006 Message Diagnostic boot completed. Detailed Description The system has successfully booted to diagnostics. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1008 Message CD-ROM boot completed. Detailed Description The system OS has successfully booted from the CD-ROM. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1010 Message ROM boot completed. Detailed Description The system has successfully booted to ROM. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1012 Message Boot completed. Detailed Description The system has successfully booted. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC CMC 854 ✔* Reset Chassis Event Proxy
37 PCI Event Messages PCI1300 Message A front panel diagnostic interrupt was detected. Detailed Description The front panel diagnostic was pressed, and the system may be halted as a result. The interrupt was user induced. Recommended Response Action Reset the system to continue operation.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1304 Message An I/O channel check error was detected. Detailed Description None Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
Recommended Response Action Reboot the system and update the component drivers. Category System Health (PCI = PCI Device) Severity Severity 1 (Critical) Trap/EventID 2417 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1308 Message A PCI parity error was detected on a component at bus arg1 device arg2 function arg3 .
PCI1310 Message A PCI system error was detected on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PCI1314 Message A bus correctable error was detected on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, if device is removable re-install the device at the next scheduled service time.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1318 Message A fatal error was detected on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description System performance may be degraded, or system may fail to operate.
Recommended Response Action Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
PCI1321 Message A high-severity issue is detected in a component of the bus arg1 , device 0, function arg2 . Arguments arg1 = bus ID, arg2 = function ID Detailed Description A high-severity issue is detected in the component identified in the message. Recommended Response Action Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1342 Message A bus time-out was detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded. The device has failed to respond to a transaction (master/target abort or completion timeout).
Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message An I/O channel check error detected. Power cycle system. Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1346 Message A software error was detected on a component at slot arg1 .
Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device. Category System Health (PCI = PCI Device) Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message PCI parity error on slot .
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PCI1354 Message A bus correctable error was detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next scheduled service time.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1358 Message A fatal error was detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded, or system may fail to operate.
Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device. Category System Health (PCI = PCI Device) Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message Bus fatal error on slot .
PCI2000 Message A fatal IO error detected on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI2002 Message A fatal IO error detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device.
Recommended Response Action No response action is required. Category System Health (PCI = PCI Device) Severity Severity 3 (Informational) Trap/EventID 2419 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3000 Message Device option ROM on embedded NIC failed to support Link Tuning or FlexAddress.
Detailed Description None Recommended Response Action No response action is required. Category System Health (PCI = PCI Device) Severity Severity 3 (Informational) Trap/EventID 2419 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3002 Message Failed to program virtual MAC address on a component at bus arg1 device arg2 function arg3 .
PCI3003 Message Virtual MAC address for component at bus arg1 device arg2 function arg3 was successfully programed. Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3005 Message Device option ROM on mezzanine card arg1 was successfully updated. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2417 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3007 Message Link Tuning or FlexAddress data successfully obtained. Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next service window.
PCI3010 Message A non-fatal IO error detected on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next service window.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3012 Message The QuickPath Interconnect (QPI) width degraded. Detailed Description System performance may be degraded. The bus is not operating at maximum speed or width. Recommended Response Action Reset the system, if the problem persists reinstall processors.
Trap/EventID Filter Visibility iDRAC 2419 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3014 Message A non-fatal PCIe error detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded.
Recommended Response Action No response action is required. Category System Health (PCI = PCI Device) Severity Severity 3 (Informational) Trap/EventID 2419 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3016 Message Device option ROM on mezzanine card failed to support Link Tuning or FlexAddress.
Detailed Description None Recommended Response Action No response action is required. Category System Health (PCI = PCI Device) Severity Severity 3 (Informational) Trap/EventID 2419 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3018 Message New PCI card(s) have been detected in the system.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔* CMC LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PCI3019 Message A low-severity issue is detected in the SSD bay arg1 , Slot arg2 . Arguments arg1 = bay id, arg2 = slot id Detailed Description A low-severity issue was detected in the SSD bay identified in the message.
Detailed Description A low-severity issue is detected in the component identified in the message. Recommended Response Action Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrence of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* ✔* PCI5002 Message A PCIe card carrier that does not contain a PCIe card is inserted in the PCIe slot arg1 . Arguments arg1 = slot number Detailed Description A PCIe card carrier that does not contain a PCIe card is inserted in the PCIe slot identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* PCI5004 Message A power fault issue is detected in the PCIe adapter that was turned on in PCIe slot arg1 .
Detailed Description Chassis Management Controller (CMC) detected an issue in the PCIe adapter that was turned on in the slot identified in the message. Recommended Response Action Make sure that: 1) The PCIe adapter used is supported by the Chassis Management Controller (CMC). For a list of supported adapters, contact your service provider. 2) The adapter is not damaged. 3) The adapter is properly inserted in the slot.
PCI5007 Message The auxiliary power-related issue of the PCIe adapter in slot arg1 is resolved. Arguments arg1 = slot number Detailed Description The 3.3 Volt Regulator power related issue of PCIe carrier present in the slot identified in the message is resolved. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* PCI5009 Message The PCIe adapter in the PCIe slot arg1 was removed from the slot while the server arg2 was turned-on.
38 PDR Event Messages PDR1 Message arg1 copyback stopped for rebuild. Arguments arg1 = physical disk Detailed Description This message is generated after a copyback stops on a physical disk during a rebuild operation. Recommended Response Action Wait for rebuild to finish, then copyback should resume.
Severity Severity 3 (Informational) Trap/EventID 4347 OMSA Event ID 2065 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR100 Message Dedicated Hot Spare arg1 no longer useful for all arrays.
PDR1000 Message Drive arg1 is installed in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR1002 Message A predictive failure detected on drive arg1 in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description The controller received a SMART error from the drive. The drive is operational but needs replacement.
Category System Health (PDR = Physical Disk) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1004 Message Consistency check is in progress for drive arg1 in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 1 (Critical) LCD Message Drive in disk drive bay is in the critical array. Replace drive. Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1006 Message Drive arg1 in disk drive bay arg2 is in the failed array.
PDR1007 Message Rebuild is in progress for drive arg1 in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PDR101 Message Global Hot Spare arg1 does not cover all arrays. Arguments arg1 = PD Name Detailed Description This alert message occurs if there are arrays not protected with a global hot spare. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2297 LCD Message Drive removed from disk drive bay . Check drive. Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR1017 Message Drive arg1 in disk drive bay arg2 is operating normally.
Detailed Description None Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR102 Message The Patrol Read operation was manually stopped before completion.
PDR1020 Message Consistency check for drive arg1 in disk drive bay arg2 completed. Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PDR1022 Message Drive arg1 in disk drive bay arg2 is no longer in the failed array. Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1024 Message Drive mismatch detected for drive arg1 in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description The installed disk does not meet the array requirements, for example a SATA disk may not operate in an array containing SAS drives.
Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 2299 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR103 Message Cryptographic Erase operation is successfully completed on arg1 .
PDR104 Message The arg1 has turned off because the critical temperature threshold is exceeded. Arguments arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message has turned off because the critical temperature threshold of the device was exceeded. Recommended Response Action Contact your service provider.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR106 Message The physical disk drive arg1 is unassigned as a dedicated hot-spare. Arguments arg1 = physical disk drive name Detailed Description A physical disk identified in the hot-spare that was assigned as a hot spare has been un-assigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically by the storage management software.
Severity Severity 3 (Informational) Trap/EventID 4347 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR108 Message The physical disk drive arg1 is unassigned as a global hot spare.
PDR11 Message arg1 rebuild was cancelled. Arguments arg1 = physical disk Detailed Description A user has cancelled the rebuild operation. Recommended Response Action Restart the rebuild operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PDR1100 Message Drive arg1 is installed. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Remove and reseat the failed disk. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 2297 LCD Message Fault detected on drive . Check drive.
PDR1103 Message Drive arg1 is the hot-spare drive. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1104 Message Consistency check is in progress for drive arg1 .
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PDR1105 Message Drive arg1 is in the critical array. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 1 (Critical) LCD Message Drive is in the critical array. Replace drive.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1107 Message Rebuild is in progress for drive arg1 . Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR111 Message The volatile memory backup device on arg1 is no longer functional. Arguments arg1 = PCIe solid state device name Detailed Description The volatile memory backup device on the PCIe solid state device identified in the message is no longer functional. Data loss is possible.
Detailed Description The controller detected a drive removal Recommended Response Action If unintended, verify drive installation. Remove and reseat the indicated disk. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 2297 LCD Message Drive is removed.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR1119 Message Drive arg1 is no longer the hot-spare drive. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR1120 Message Consistency check for drive arg1 completed. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1122 Message Drive arg1 is no longer in the failed array. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Category System Health (PDR = Physical Disk) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR113 Message The arg1 has reached or exceeded its warranted wear-out limit.
Detailed Description The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode. Recommended Response Action No response action is required.
PDR116 Message Predictive failure reported for arg1 Arguments arg1 = PCIe solid state device name Detailed Description The PCIe Solid-State Drive is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART monitors the disk health based on indications such as the number of write operations that were performed on the disk.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR12 Message arg1 initialization has failed. Arguments arg1 = PD Name Detailed Description The physical disk has failed or is corrupt. Recommended Response Action Replace the failed or corrupt disk. Identify a disk that has failed by locating the disk that has a red "X" for its status.
Recommended Response Action Replace the failed or corrupt disk, and then start the rebuild operation. Category Storage (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 4345 OMSA Event ID 2083 OMSA Trap ID 90400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR14 Message arg1 initialization is complete.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR15 Message arg1 rebuild is complete. Arguments arg1 = physical disk Detailed Description This message is generated after a rebuild completes on a physical disk. Recommended Response Action No response action is required.
Category Storage (PDR = Physical Disk) Severity Severity 2 (Warning) Trap/EventID 4346 OMSA Event ID 2094 OMSA Trap ID 90300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR17 Message Global hot spare assigned to arg1 .
PDR18 Message Global hot spare unassigned from arg1 . Arguments arg1 = PD Name Detailed Description A physical disk assigned as a hot spare was unassigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically unassigned by Storage Management. Storage Management unassigns hot spares were used to rebuild data. Once the data is rebuilt onto the hot spare, the hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare.
Severity Severity 2 (Warning) Trap/EventID 4346 OMSA Event ID 2106 OMSA Trap ID 90300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR2 Message Insufficient space available on arg1 to perform a copyback operation.
PDR20 Message SMART configuration change for arg1 . Arguments arg1 = PD Name Detailed Description A disk has received a SMART alert (predictive failure) after a configuration change. The disk is likely to fail in the near future. Recommended Response Action Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR207 Message Unable to assign arg1 as a dedicated hot spare. Arguments arg1 = physical disk name Detailed Description Unable to assign the physical disk as a dedicated hot spare because the selected disk size does not meet the size requirements of the target Virtual Disk.
Recommended Response Action No response action is required. Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) OMSA Event ID 2390 OMSA Trap ID 90100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR209 Message The power status of arg1 is changed from arg2 to arg3 .
PDR21 Message SMART warning for arg1 Arguments arg1 = PD Name Detailed Description A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near future. Recommended Response Action Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.
Severity Severity 3 (Informational) OMSA Event ID 2400 OMSA Trap ID 90100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR211 Message arg1 has encountered storage medium error. Arguments arg1 = physical disk name Detailed Description Storage medium error was detected on the disk identified in the message.
Arguments arg1 = physical disk name Detailed Description The physical disk state has changed from Ready state to Non-RAID state. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR214 Message The arg1 is not supported because it is not supplied by an authorized hardware provider. Arguments arg1 = physical disk name Detailed Description The physical disk identified in the message is not compliant with the standards set by the hardware provider and is not supported.
Severity Severity 1 (Critical) OMSA Event ID 2183 OMSA Trap ID 90400 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR22 Message SMART warning temperature for arg1 Arguments arg1 = PD Name Detailed Description A disk has reached an unacceptable temperature and received a SMART alert (predictive failure).
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR23 Message SMART warning degraded for arg1 Arguments arg1 = PD Name Detailed Description A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the near future. Recommended Response Action Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.
Severity Severity 2 (Warning) Trap/EventID 4346 OMSA Event ID 2111 OMSA Trap ID 90300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR25 Message arg1 dead segments are removed. Arguments arg1 = PD Name Detailed Description Portions of the physical disk that were formerly inaccessible have been recovered.
PDR26 Message arg1 is online. Arguments arg1 = physical disk Detailed Description A drive has entered the online state. This may be because the system just started or could be because a problem with the drive has been corrected. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR28 Message Dedicated hot spare unassigned from arg1 . Arguments arg1 = PD Name Detailed Description A physical disk that was assigned as a hot spare has been unassigned and is no longer functioning as a hot spare.
PDR29 Message Rebuild on arg1 completed with error(s). Arguments arg1 = PD Name Detailed Description See A Rebuild Completes with Errors for more information. Recommended Response Action See A Rebuild Completes with Errors for more information.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR30 Message A global hot spare failed. arg1 Arguments arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable.
Arguments arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable. Recommended Response Action Verify that the disk is healthy and installed. Check the cables. Refer to the product documentation and see the Cables Attached Correctly section for more information on checking the cables. If necessary, replace the disk and reassign the global hot spare.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR33 Message A dedicated hot spare has been removed. arg1 Arguments arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable.
Arguments arg1 = PD Name Detailed Description The hot spare is no longer required because the virtual disk it was assigned to has been deleted. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR36 Message The only hot spare available is a SAS disk arg1 . Arguments arg1 = PD Name Detailed Description The only physical disk available to be assigned as a hot spare is using SAS technology. The physical disks in the virtual disk are using SATA technology.
Detailed Description The physical device may not have a supported version of the firmware or the physical device may not be supported. Recommended Response Action If the physical device is supported, then update the firmware to a supported version. If the physical device is not supported, then replace the physical device with one that is supported.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR39 Message A blink operation has initiated on arg1 . Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Trap/EventID Filter Visibility 4347 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR40 Message The blink operation has ceased on arg1 . Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Detailed Description The clear command did not complete on the physical disk. This means that some data was not cleared and may be recoverable. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR43 Message The clear operation on arg1 has completed. Arguments arg1 = physical disk Detailed Description This message is generated after a clear operation completes on a physical disk. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 4345 OMSA Event ID 2270 OMSA Trap ID 90400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR46 Message Patrol Read found an uncorrectable media error on arg1 .
PDR47 Message A block on arg1 was punctured by the controller. Arguments arg1 = physical disk Detailed Description The controller encountered an unrecoverable medium error when attempting to read a block on the physical disk and marked that block as invalid. If the controller encountered the unrecoverable medium error on a source physical disk during a rebuild or reconfigure operation, it punctures the corresponding block on the target physical disk. The invalid block clears on a write operation.
OMSA Event ID 2274 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR49 Message The dedicated hot spare arg1 is too small. Arguments arg1 = PD Name Detailed Description The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk group.
Arguments arg1 = PD Name Detailed Description A physical disk has been removed from the disk group. This alert can also be caused by loose or defective cables or by problems with the enclosure. Recommended Response Action Do one of the following: 1) If a physical disk was removed from the disk group, either replace the disk or restore the original disk. Identify the disk that was removed by locating the disk that has a red "X" for its status. 2) Perform a rescan after replacing or restoring the disk.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR51 Message Hot spare arg1 SMART polling has failed. arg2 Arguments arg1 = physical disk, arg2 = args Detailed Description The controller firmware attempted to do SMART polling on the hot spare but could not complete the SMART polling.
Detailed Description The controller has two connectors that are connected to the same enclosure. The communication path on one connector has lost connection with the enclosure. The communication path on the other connector is reporting this loss. Recommended Response Action Make sure the cables are attached securely. See the Cables Attached Correctly section for more information on checking the cables. Make sure both Enclosure Management Modules (EMMs) are healthy.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR54 Message A disk media error on arg1 was corrected during recovery. Arguments arg1 = physical disk Detailed Description This message is generated after a disk media error is corrected on a physical disk. Recommended Response Action No response action is required.
Trap/EventID 4346 OMSA Event ID 2305 OMSA Trap ID 90300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR56 Message Bad block table on arg1 is 80% full. Arguments arg1 = physical disk Detailed Description The bad block table is the table used for remapping bad disk blocks.
PDR57 Message Bad block table on arg1 is full. Unable to log block arg2 . Arguments arg1 = physical disk, arg2 = logical block address Detailed Description The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which means that disk errors are no longer corrected. At this point, data loss can occur.
OMSA Event ID 2309 OMSA Trap ID 90300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR59 Message A bad disk block was reassigned on arg1 . Arguments arg1 = physical disk Detailed Description The disk has a bad block. Data was remapped to another disk block. No data loss has occurred.
Arguments arg1 = physical disk Detailed Description A physical disk in the virtual disk is offline. This may have been user initiated. Recommended Response Action Force the physical disk online or assign a hot spare to the virtual disk.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR61 Message The rebuild of arg1 failed due to errors on the source physical disk. Arguments arg1 = physical disk Detailed Description It is not possible to rebuild data that resides on a defective disk.
Recommended Response Action Replace the target disk. If a rebuild does not automatically start after replacing the disk, then initiate the Rebuild task. You may need to assign the new disk as a hot spare to initiate the rebuild.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR64 Message An unrecoverable disk media error occurred on arg1 . Arguments arg1 = physical disk Detailed Description The rebuild or recovery operation encountered an unrecoverable disk media error. Recommended Response Action Replace the disk.
Trap/EventID 4347 OMSA Event ID 2351 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR66 Message arg1 that was marked as missing has been replaced. Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
PDR67 Message An unsupported physical disk drive has been detected. Detailed Description The physical disk does not comply with the standards set by service provider and is not supported. Recommended Response Action Replace the physical disk with a supported physical disk.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR69 Message Rebuild not possible on arg1 . Arguments arg1 = physical disk Detailed Description Physical disk inserted is of the incorrect protocol. SAS or SATA mixing is not supported in the same virtual disk. Recommended Response Action Remove drive, insert correct protocol type, and force a rebuild as imposed for controller and system.
Severity Severity 2 (Warning) Trap/EventID 4346 OMSA Event ID 2051 OMSA Trap ID 90300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR70 Message Copyback started from arg1 to arg2 .
PDR71 Message Copyback completed from arg1 to arg2 . Arguments arg1 = physical disk, arg2 = physical disk Detailed Description The copyback operation completed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR73 Message Copyback failed from arg1 to arg2 . Arguments arg1 = physical disk, arg2 = physical disk Detailed Description The physical disk participating in the copyback operation failed. Recommended Response Action Replace the disk and retry the operation.
Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 4347 OMSA Event ID 2184 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR75 Message Copyback stopped for hot spare arg1 .
PDR76 Message Copyback not possible as SAS or SATA mixing is not supported. Detailed Description Copyback not possible as SAS or SATA mixing is not supported in the same virtual disk. This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR78 Message arg1 state changed from Non-RAID to READY. Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR8 Message arg1 is inserted. Arguments arg1 = PD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 4347 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR82 Message arg1 security was activated.
PDR83 Message arg1 is reprovisioned. Arguments arg1 = PD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR85 Message Security subsystem errors detected for arg1 . Arguments arg1 = physical disk Detailed Description Errors were detected with security related operations on the disk. The data on the disk might not be retrieved or stored successfully. In addition, the security of the stored data might be at risk. Recommended Response Action Verify the disk is a Secure Encrypted Disk and is not locked.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR87 Message arg1 was reset. Arguments arg1 = physical device Detailed Description The physical device was reset. This is a normal part of operations and is not a cause for concern. Recommended Response Action No response action is required.
Recommended Response Action Replace the physical disk and try again. Contact technical support if the issue persists.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR9000 Message Foreign Configuration was detected on arg1 . Arguments arg1 = physical disk drive name Detailed Description Internal Use Only. Recommended Response Action Internal Use Only.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR94 Message Microcode update on arg1 has timed out. Arguments arg1 = physical disk Detailed Description The attempt to update the physical disk has timed out. This may be due to too much activity on the bus, a bad update package, or a bad disk.
Recommended Response Action Retry the update. If the update fails a second time, verify the update package is valid. If the update package is valid, replace the failing disk. Contact technical support if the problem persists.
PDR97 Message arg1 security key required. Arguments arg1 = physical disk Detailed Description The controller detected drives that require security keys for access. Without providing security keys, the drives are unstable. Recommended Response Action Provide the security key required to unlock the secure encrypted drives.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ 982 LCD ✔ ✔* Reset Chassis Event Proxy
39 PFM Event Messages PFM0001 Message The value of arg1 is greater than the upper critical threshold. Arguments arg1 = sensor name Detailed Description The utilization value of the sensor identified in the message is higher than the upper critical threshold. Recommended Response Action Check the work load of the server and reduce the workload if necessary to bring the system performance into required ranges.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PFM0003 Message The value of arg1 is less than the lower warning threshold. Arguments arg1 = sensor name Detailed Description The utilization value of the sensor identified in the message is lower than the lower warning threshold value. Recommended Response Action The workload on server is almost zero. Consider assigning additional workloads to the server.
40 POW Event Messages POW000 Message Power on permission error, chassis infrastructure not ready. Detailed Description Host failed to power up because chassis infrastructure is not ready. This messages has been replaced by Message ID PWR2250 Recommended Response Action Check status of chassis infrastructure.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC POW002 Message Power on permission error, unknown component installed in Fabric1/Fabric2. Detailed Description Host failed to power up because unsupported components installed in Fabric1/ fabric2.This messages has been replaced by Message ID PWR2252 Recommended Response Action Check for unsupported components installed in Fabric1/Fabric2.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC POW004 Message Power on permission error, unacknowledged use of 110V. Detailed Description Host failed to power up because of unacknowledged use of 110V. This messages has been replaced by Message ID PWR2254 Recommended Response Action Check for unacknowledged use of 110V.
LC Log iDRAC CMC 988 ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
41 PR Event Messages PR1 Message A replacement part was detected for device: arg1 Arguments arg1 = device name Detailed Description The specified device has been replaced. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR11 Message A required license for the Part Replacement feature is not present, replacement action(s) will not be performed. Detailed Description A valid license for this feature is not present.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR13 Message Firmware mismatch detected. Configuration changes not applied. Detailed Description The Part Replacement feature detected a firmware difference and cannot apply the configuration changes. After the device firmware is updated, configuration changes can be applied.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR15 Message Unable to verify configuration changes for device: arg1 Arguments arg1 = device name Detailed Description The configuration changes requested have not passed the device specific verification check and will not be applied.
Recommended Response Action Check the current system configuration and ensure all settings are correct. If not, retry the operation.
Arguments arg1 = device name Detailed Description The Part Replacement feature has detected a firmware difference between the current and previous components. Depending on the Part Firmware Update setting value this may cause a firmware update to the replaced part. Recommended Response Action No response action is required.
PR2 Message Configuration difference detected for device: arg1 Arguments arg1 = device name Detailed Description The specified device configuration is different from the previous device configuration. Recommended Response Action No response action is required.
PR21 Message Job failed. Detailed Description The specified job did not complete successfully. Recommended Response Action Check the Lifecycle Log for more details associated with this failure then retry the operation.
PR23 Message Job is ready for execution. Detailed Description The specified job is ready to start. It is waiting for scheduling from job control. This message is no longer in use in Lifecycle Controller 2.0 as the job control functionality handles this operation. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR25 Message Missing or corrupt configuration database. Detailed Description The systems configuration database is missing or is unreadable. This may be due to a user action such as Lifecycle Controller Wipe or a replaced motherboard. Recommended Response Action Enable the Collect System Inventory on Restart attribute of the Lifecycle Controller and restart the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR27 Message Unable to allocate resources. Detailed Description The system ran out of memory while attempting to perform an operation. This has been deprecated. Recommended Response Action Retry the operation. If more than one operation was attempted retry them one at a time.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR29 Message Unable to locate device in previous configuration. Detailed Description The device that the job was intended for has no previous information recorded. The request has failed as this information is required to initiate the operation. This has been deprecated. Recommended Response Action Enable the Collect System Inventory on Restart attribute of the Lifecycle Controller and restart the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR30 Message Job processing initialization failure. Detailed Description Operation validation was unsuccessful. The command, target and operation data are all validated before proceeding. If any of them are missing or incorrect the request is failed. Recommended Response Action Enable the Collect System Inventory on Restart attribute of the Lifecycle Controller and restart the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR32 Message Failed verification of configuration changes. Detailed Description The configuration changes requested, for the indicated job, have not passed the device specific verification check and will not be applied.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR34 Message arg1 failed after exceeding retry attempt limit. Arguments arg1 = job ID Detailed Description The job was attempted but failed unexpectedly. An AC Power loss, system crash, or other interruption during the job processing can cause this failure. Recommended Response Action Recreate and resubmit the job.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR36 Message Version change detected for arg1 firmware. Previous version: arg2 , Current version: arg3 Arguments arg1 = device name, arg2 = previous version, arg3 = current version Detailed Description The system has detected a different firmware version than previously recorded for the indicated device.
Category Configuration (PR = Part Exchange) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR5 Message The configuration values stored for the previous device could not be applied to device: arg1 Arguments arg1 = device name Detailed Description Some or all configuration values stored for the previous device could not be appl
Detailed Description The configuration values stored for the previous device were applied to the current device. Recommended Response Action No response action is required.
Arguments arg1 = device name Detailed Description The indicated device has been removed from the system, is no longer functioning, or has been disabled. Recommended Response Action If the part is present, make sure it is properly installed. Ensure that the device has not been disabled in the system BIOS or other configuration utility. Contact technical support if the device is still non functional.
42 PST Event Messages PST0000 Message Unrecognized Post Code. Detailed Description The BIOS provided a progress code to the iDRAC, but that progress code is not recognized by the current iDRAC firmware. Recommended Response Action Do one of the following: 1) Update the iDRAC firmware. 2) Restart the system and retry the operation. If the issue persists, contact your service provider. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Unrecognized Post Code.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0002 Message CPU Microcode load. Detailed Description System BIOS has started loading the processor microcode. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message CPU Microcode load.
LCD Message Filter Visibility Started chipset initialization. IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0004 Message Memory Configuration. Detailed Description System BIOS has started memory configuration. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) LCD Message Shadow BIOS operation started. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0006 Message Multiprocessor Initialization. Detailed Description System BIOS has started initialization multiprocessor support. Recommended Response Action No response action is required.
Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Started power on self test (POST). Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0008 Message System Management Mode (SMM)initialization. Detailed Description System BIOS has started System Management Mode (SMM) initialization.
Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message PCI bus enumeration & video initialization. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0010 Message iDRAC is ready. Detailed Description The iDRAC initialization is completed.
Detailed Description System started extended memory test. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Extended memory test started. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0012 Message Extended Memory test running \ Detailed Description Syste
PST0013 Message Extended Memory test running / Detailed Description System extended memory test in progress. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0064 Message Display sign-on. Detailed Description System BIOS is displaying power on splash screen. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Display sign-on.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0080 Message An issue was detected. System at boot F1/F2 prompt. Requires entry to continue. Detailed Description System is at the F1/F2 prompt because the system BIOS detected an issue other than "No bootable devices". Recommended Response Action Check post display screen for details.
Severity Severity 1 (Critical) LCD Message No bootable devices found. Check bootable devices. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0082 Message In BIOS Setup Menu. Detailed Description System is at the BIOS Setup Menu. Recommended Response Action No response action is required.
Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message In BIOS Boot Menu. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0084 Message Automated Task application. Detailed Description System started the Automated Task application. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Performing CSIOR. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0086 Message In Lifecycle Controller. Detailed Description System BIOS has launched the Lifecycle Controller user interface.
Detailed Description System BIOS is initializing iDRAC. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Initializing iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0088 Message Preparing to Boot.
PST0089 Message A problem was detected during Power-On Self-Test (POST). Detailed Description A problem was detected during Power-On Self-Test (POST). The next logged message contains more specific details for the detected issue. Recommended Response Action Review the next logged message for the recommended response action to resolve the problem.
PST0091 Message A problem was detected in Memory Reference Code (MRC). Detailed Description A problem was detected in Memory Reference Code (MRC). The next logged message contains more specific details for the detected issue. Recommended Response Action Review the next logged message for the recommended response action to resolve the problem.
PST0127 Message Giving control to OS. Detailed Description System BIOS gave control to the operating system. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Giving control to OS.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PST0129 Message Memory is detected, but is not configurable. Detailed Description System BIOS detected memory, but was unable to configure the memory for system operation. Compare system memory installation to supported system memory configurations. Reduce the system to minimum memory configuration if acceptable. This exception occurred early in system power on, thus the system may not display video.
Trap/EventID 2425 LCD Message Memory is configured, but not usable. Check memory devices Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0131 Message System BIOS shadow failed. Detailed Description Memory errors occurred copying BIOS image into system memory.
Recommended Response Action Check system event log for CMOS battery exceptions. Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message CMOS failed.
PST0134 Message Interrupt controller failed. Detailed Description System BIOS detected a failure with the interrupt controller during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code 86) Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0136 Message Programmable interval timer error. Detailed Description System BIOS detected an failure with the programmable interval timer during POST. This exception occurred early in system power on, thus the system may not display video.
Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Parity error.
PST0139 Message Keyboard controller failed. Detailed Description System BIOS detected a failure with the Keyboard Controller. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code 8B) Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0141 Message QuickPath Interconnect (QPI) fatal error. Detailed Description Quick Path Interconnect failed during system POST. Reboot the system. If problem persists, remove input power and reseat processors. This exception occurred early in system power on, thus the system may not display video.
Recommended Response Action Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Memory initialization error.
PST0144 Message Unable to load required BIOS files. Detailed Description System BIOS is unable to load the required BIOS files. Recommended Response Action Remove and reapply power to server. If the problem persists, contact your server provider. Refer to the product documentation to choose a convenient contact method. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) LCD Message Unable to load required BIOS files.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PST0193 Message BIOS POST memory test failed. Detailed Description System BIOS POST memory test failed. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code C1) Recommended Response Action Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0195 Message CPU configuration failed. Detailed Description The current processor configuration is unsupported or encountered a fatal exception during POST. Check the processor configuration. This exception occurred early in system power on, thus the system may not display video.
Recommended Response Action Re-install memory to match supported memory configuration. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Incorrect memory configuration. Review User Guide Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0208 Message System BIOS has halted.
PST0209 Message System BIOS has halted due to Non-Maskable Interrupt (NMI). Detailed Description System BIOS has halted and is unable to continue. System BIOS has detected a Non-Maskable Interrupt (NMI) which may have been caused by a hardware change. Recommended Response Action Do one of the following: 1) If new hardware has been added, remove the new hardware and restart the server, 2) Turn server off and back on using the power button, or 3) Remove and reapply server input power.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0256 Message POST fatal error detected. Detailed Description System BIOS detected a functional or configuration issue during system POST. Check the system video screen for more information. The system event log may contain additional details.
43 PSU Event Messages PSU0000 Message Power supply arg1 is present. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Trap/EventID 2185 LCD Message PSU failed. Check PSU OMSA Event ID 5300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy PSU0002 Message A predictive failure detected on power supply arg1 . Arguments arg1 = number Detailed Description System performance and power redundancy may be degraded or lost.
PSU0003 Message The power input for power supply arg1 is lost. Arguments arg1 = number Detailed Description The power supply is installed correctly but an input source is not connected or is not functional. Recommended Response Action Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy PSU0005 Message The power input for power supply arg1 is outside of the allowable range, but it is attached to the system.
Detailed Description The power supply identified in the message must be supported by the platform. Generally, multiple power supplies in the server should have the same feature set and power rating. Recommended Response Action Review server product documentation for supported power supplies and power supply configurations. Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Power supply is incorrectly configured. Check PSU.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy PSU0017 Message Power supply arg1 is operating normally. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Trap/EventID 2187 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ PSU0022 Message Power supply arg1 is correctly configured. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔* IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing Reset Chassis Event Proxy PSU0031 Message Cannot communicate with power supply arg1 .
PSU0032 Message The temperature for power supply arg1 is in a warning range. Arguments arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* PSU0034 Message An under voltage fault detected on power supply arg1 . Arguments arg1 = number Detailed Description This failure may be the result of an electrical issue with cables or subsystem components in the system. Recommended Response Action 1) Remove and re-install the power supply. 2) Check cables and subsystem components in the system for damage.
Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Over voltage fault on PSU . Check PSU Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* PSU0036 Message An over current fault detected on power supply arg1 .
PSU0037 Message Fan failure detected on power supply arg1 . Arguments arg1 = number Detailed Description None Recommended Response Action Check for fan blockage. If not replace the power supply. Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Fan failure detected on PSU . Check PSU.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PSU0039 Message An under current fault detected on power supply arg1 . Arguments arg1 = number Detailed Description Insufficient amount of current to keep power supply operating at a normal levels. Recommended Response Action 1) Remove and re-install the power supply input cord. 2) Check power distribution or PSU input source for anomalies. 3) If the issue persists, contact technical support.
Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Output under voltage fault detected on PSU . Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* PSU0041 Message An output over voltage fault detected on power supply arg1 .
PSU0042 Message An output over current fault detected on power supply arg1 . Arguments arg1 = number Detailed Description none Recommended Response Action 1) Remove the power supply input cord and then remove power supply. 2) Reinstall the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* PSU0044 Message Cannot obtain status information from power supply arg1 . Arguments arg1 = number Detailed Description The power supply is operating but the system cannot get status information.
Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Trap/EventID 2187 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* PSU0046 Message Communication has been restored to power supply arg1 .
Arguments arg1 = number, arg2 = value Detailed Description Power supplies should be of the same input type and power rating. Recommended Response Action Install matched power supplies and review product documentation for proper configuration.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* PSU0078 Message Power supply arg1 revision mismatch detected. Arguments arg1 = number Detailed Description This power supply revision is not supported for this system. Recommended Response Action Review product documentation, change power supply with correct revision.
Trap/EventID 2185 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* PSU0090 Message Power supply arg1 wattage mismatch corrected. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Remove the power supply unit identified in the message and review server product documentation for appropriate configuration. Category System Health (PSU = Power Supply) Severity Severity 2 (Warning) Trap/EventID 2186 LCD Message Power supply exceeds power distribution limits. Remove PSU.
PSU0800 Message Power Supply arg1 : Status = 0x arg2 , IOUT = 0x arg3 , VOUT= 0x arg4 , TEMP= 0x arg5 , FAN = 0x arg6 , INPUT= 0x arg7 Arguments arg1 = PSU_name, arg2 = PSU_Status, arg3 = Output_Current, arg4 = Output_Voltage, arg5 = Temp, arg6 = Fan, arg7 = Input Detailed Description Lists the complete status of the power supply unit. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PSU0802 Message The power supply redundancy policy on the system has been set. Detailed Description The power supply redundancy policy on the system has been set. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PSU0900 Message Power unit arg1 is off. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0902 Message Power unit arg1 was power cycled. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0906 Message An interlock power down error detected on power unit arg1 . Arguments arg1 = number Detailed Description In order to meet service requirements the supply must be shut down. Recommended Response Action Remove input power at the power supply.
Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0908 Message Power lost on power unit arg1 . Arguments arg1 = number Detailed Description The power supply is installed correctly but an input source is not connected or is not functional.
Detailed Description None Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0910 Message Soft power control failure detected on power unit arg1 .
Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0912 Message A failure detected on power unit arg1 .
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PSU0913 Message Power unit arg1 is operating normally. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU100 Message Power supply arg1 is offline. Arguments arg1 = power supply unit Detailed Description The power supply unit identified in the message is offline, because of the one of the following reasons: 1) The power supply unit is not correctly seated.
Detailed Description The power supply unit is not receiving input AC power. The power cable may not be connected properly or removed. This can happen if there is an AC failure or problems with the power strip attached to the enclosure power supply. Recommended Response Action Reconnect the power cable to the power supply unit if it was disconnected. Restore the input AC power supply. Make sure the power supply is restored to the enclosure from the mains.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* PSU1002 Message arg1 was removed Arguments arg1 = PSU Sensor Name Detailed Description The enclosure detected that a power supply unit was removed and is no longer functioning in optimal condition. Recommended Response Action Re-insert the power supply unit into the enclosure. Re-connect the AC power cable and switch on the power supply unit. Contact technical support if the issue persists.
Category Storage (PSU = Power Supply) Severity Severity 2 (Warning) Trap/EventID 4234 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* PSU1004 Message Power supply cable has been inserted into arg1 .
PSU1005 Message arg1 is switched on. Arguments arg1 = PSU sensor name Detailed Description The enclosure detected that a power supply unit was switched on. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* PSU1007 Message arg1 has failed. Arguments arg1 = PSU Sensor Name Detailed Description A device has been failed and the system is no longer functioning in optimal condition. Recommended Response Action Replace the device.
Recommended Response Action Do one of the following to resolve the issue: 1) reseat the power supply unit. 2) Reconnect the power cable to the power supply unit. 3) Install a new power supply unit 4) Restore the input power supply.
PSU102 Message Power supply arg1 status is unknown. Arguments arg1 = power supply unit Detailed Description The status of the power supply unit identified in the message is unknown, because of one of the following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not be connected properly or disconnected. 3) The power supply unit has failed. 4) There is an input power failure.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PSU500 Message Unable to get the current server power status. Detailed Description Racadm tool cannot obtain the power status possible reason is that the IPMI call failed. Recommended Response Action No response action is required.
Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) No alerts are applicable for this message PSU503 Message Server power status: arg1 Arguments arg1 = Status Detailed Description Success message. Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) No alerts are applicable for this message PSU504 Message Server power operation successful Detailed Description Success message.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PSU8502 Message The PSU in slot arg1 detected 110 VAC input voltage and does not match chassis configuration. Arguments arg1 = slot number Detailed Description The input voltage of the PSU specified in the message does not match the input voltage of the PSUs already present in the chassis.
Recommended Response Action Do the following: 1) Check if the input voltage of all the PSUs are the same. 2) If the input voltage of the PSU specified in the message is not the same, then remove the unmatched PSU.
Detailed Description Unable to set the chassis redundancy policy to AC Redundancy. Recommended Response Action Retry the operation using the CMC command line interface or CMC Web interface. To set the chassis redundancy policy using the command line, enter "racadm config -g cfgChassisPower -o cfgChassisRedundancyPolicy 1". To configure the chassis redundancy policy using the Web interface, click Chassis Overview > Power > Configuration. From the Redundancy drop-down menu, select AC Redundancy.
PSU8507 Message Insufficient power available because PSU in the slot arg1 is not present.. Arguments arg1 = slot number Detailed Description The PSU identified in the message has been disengaged or removed. Insufficient power is available. Recommended Response Action Insert a PSU in the slot identified in the message.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PSU8510 Message PSU in slot arg1 FW updated successfully to version arg2 Arguments arg1 = slot number, arg2 = version number Detailed Description The firmware for the PSU identified in the message is successfully updated to the version displayed in the message Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle WS Eventing Reset Chassis Event Proxy ✔* PSU8512 Message Unable to update the firmware for the PSU in slot arg1 .
Category Audit (PSU = Power Supply) Severity Severity 2 (Warning) Trap/EventID 8330 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* PSU8515 Message Unable to set the Enable Dynamic Power Supply Engagement attribute. Detailed Description Unable to set the Enable Dynamic Power Supply Engagement attribute.
Detailed Description Unable to set redundancy policy because PSU enumeration is in progress. The policy can be set after PSU enumeration is complete. Recommended Response Action Retry the operation after the PSU enumeration is complete.
Detailed Description The operation to read the FRU data from the PSU identified in the message did not complete successfully due to internal communication errors. Recommended Response Action Retry the operation. If the condition persists, contact your service provider.
PSU8520 Message Enhanced Dynamic Power Supply Engagement (DPSE) is fully supported. Detailed Description The Dynamic Power Supply Engagement feature is supported and fully operational. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* 1090 LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔*
44 PSUA Event Messages PSUA0016 Message Power supply arg1 is absent. Arguments arg1 = number Detailed Description The supply has been removed or has failed. Recommended Response Action Install the power supply if needed. Category System Health (PSUA = PSU Absent) Severity Severity 1 (Critical) Trap/EventID 2465 LCD Message PSU is absent.
45 PWR Event Messages PWR8536 Message Server Performance Over Power Redundancy is enabled. Detailed Description Server Performance Over Power Redundancy is enabled. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR0100 Message The power button was pressed. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR0102 Message The sleep button was pressed. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR0104 Message The reset button was pressed. Detailed Description The system will reset. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR0106 Message The arg1 is latched. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR0108 Message The arg1 service was requested. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR1000 Message The system performance restored. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 2274 LCD Message System performance degraded. Check PSUs and system configuration Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PWR1002 Message The system performance degraded because of thermal protection. Detailed Description To avoid shutdown, system performance has been degraded.
Recommended Response Action If unintended, review system configuration changes and thermal policy. Category System Health (PWR = Power Usage) Severity Severity 2 (Warning) Trap/EventID 2274 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PWR1004 Message The system performance degraded because power capacity has changed.
Detailed Description To avoid exceeding the user defined capacity, system performance has been degraded. Recommended Response Action If unintended, review system configuration changes and power policy.
PWR1007 Message The system performance degraded because power exceeds capacity. Detailed Description To avoid shutdown, system performance has been degraded. Recommended Response Action Review system configuration, upgrade power supplies or reduce system power consumption. Category System Health (PWR = Power Usage) Severity Severity 2 (Warning) Trap/EventID 2274 LCD Message System power exceeds capacity. Performance degraded.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PWR1009 Message System power capacity is restored. Detailed Description System power capacity is restored. Recommended Response Action No response action is required.
Category System Health (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR2000 Message The system powered up. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2002 Message The system warm reset. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2004 Message System booted automatically into diagnostics. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2006 Message The OS run-time software initiated a warm reset. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR201 Message Selecting the Server Based Power Management Mode option sets your power cap to a maximum value, server priorities to a default priority, and then disables the Max Power Conservation Mode.
Recommended Response Action No response action required. Category System Health (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR203 Message Unable to set the System Input Power Cap value to less than or equal to 13300 W (45381 BTU/h), because the Extended Power Performance feature is enabled.
Detailed Description Object value is successfully modified. Max Power Conservation Mode will deactivate the Extended Power Performance feature. Recommended Response Action No response action required.
PWR206 Message The Server Based Power Management (SBPM) feature cannot be enabled because the Extended Power Performance mode is enabled. Detailed Description The Server Based Power Management (SBPM) feature cannot be enabled because the Extended Power Performance mode is enabled. Recommended Response Action Disable Extended Power Performance and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR209 Message Unable to change the redundancy policy to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled. Detailed Description The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled. Recommended Response Action Disable Extended Power Performance and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR211 Message Unable to set the Fresh Air (FA) mode because the Extended Power Performance (EPP) feature is enabled. Detailed Description The Fresh Air (FA) mode cannot be set because the Extended Power Performance (EPP) feature is enabled. Recommended Response Action No response action required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR214 Message Cannot enable the Extended Power Performance (EPP) mode because Dynamic Power Supply Engagement (DPSE) is enabled. Detailed Description Cannot enable the Extended Power Performance (EPP) mode because Dynamic Power Supply Engagement (DPSE) is enabled. Recommended Response Action Disable Dynamic Power Supply Engagement (DPSE) and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR218 Message Cannot enable the Extended Power Performance (EPP) feature because the Fresh Air (FA) mode is enabled. Detailed Description Cannot enable the Extended Power Performance (EPP) the feature because the Fresh Air (FA) mode is enabled. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR220 Message The Extended Power Performance (EPP) feature cannot be enabled because slot arg1 is empty. Arguments arg1 = slot number Detailed Description The Extended Power Performance (EPP) feature cannot be enabled because the slot identified in the message is empty.
Category System Health (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2201 Message The system is sleeping with system hardware and processor context maintained. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2203 Message The system is sleeping with system hardware and processor context lost. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2205 Message The system is in a soft-off state. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2208 Message The system is in a sleep state. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR221 Message The Extended Power Performance (EPP) feature is already disabled. Detailed Description The Extended Power Performance (EPP) feature is already disabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2211 Message The system is in legacy ON state. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR222 Message The Extended Power Performance (EPP) feature is already enabled. Detailed Description The Extended Power Performance (EPP) feature is already enabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR2250 Message Unable to turn on the server because the chassis infrastructure not ready. Detailed Description The server did not turn on because the chassis infrastructure is not ready. The chassis infrastructure includes: PCIe subsystem, storage components, and the chassis management controller.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2252 Message Unable to turn on the server because an NDC or Mezzanine card is incompatible with the I/O Module or PCIe subsystem. Detailed Description The server did not turn on because an NDC or Mezzanine card is incompatible with the I/O Module or PCIe subsystem.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2254 Message The use of 110V is unacknowledged and the chassis cannot grant power on permission to the server. Detailed Description The use of 110V is unacknowledged for the chassis and the chassis cannot grant power on permission to the server.
Overview>Power>Configuration and then uncheck the Max Power Conservation Mode field. Category Audit (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2256 Message Unable to allocate power for servers to turn on because the Chassis Management Controller (CMC) is initializing chassis infrastructure components.
Arguments arg1 = override state, arg2 = target power Detailed Description The target power allocation override has been enabled or disabled as identified in the message. Recommended Response Action No response action required.
PWR2260 Message The Intel Management Engine is unresponsive and the server thermal failsafe state is activated. Detailed Description The iDRAC experienced an IPMB communication issue with the Intel Management Engine and was not able to recover IPMB communications. The server thermal failsafe state is activated. Recommended Response Action Disconnect power from the server and reconnect power. Turn on the server. If the issue persists, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2262 Message The Intel Management Engine has reported an internal system error. Detailed Description The Intel Management Engine is unable to utilize the PECI over DMI facility. Recommended Response Action Look for the PWR2264 "normal system operation" message in the Lifecycle Log after the PWR2262 entry. It may take 30 seconds for the message to be logged.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2264 Message The Intel Management Engine has reported normal system operation. Detailed Description The Intel Management Engine has recovered the ability to utilize the PECI over DMI facility.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2401 Message Power management firmware initialization error Detailed Description The iDRAC controller detected that the power management firmware did not initialize properly. The system may operate in a performance degraded state.
input power. 2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest revision. Category System Health (PWR = Power Usage) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2403 Message iDRAC communication with power management firmware has been restored.
Recommended Response Action No response action is required. Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR3000 Message The system is being shut down for thermal protection. Detailed Description To avoid system damage because of insufficient cooling, the system is being shut down.
Detailed Description The system has detected a new peak power value. Recommended Response Action Make sure that the power usage corresponds to the current hardware configuration and workload.
PWR8501 Message Successfully set Virtual Infrastructure Device power to arg1 WDC Arguments arg1 = power reading Detailed Description Power allocation succeeded for Virtual infrastructure. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8504 Message Chassis power button is pressed, but the button is disabled. Detailed Description The chassis power button press is detected but the button has been disabled. Recommended Response Action The chassis power button is disabled. To enable the chassis power button use the CMC RACADM command line interface, CMC Web interface.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle WS Eventing Reset Chassis Event Proxy ✔* PWR8506 Message Cumulative power computation (KWH) time is reset on arg1 . Arguments arg1 = time Detailed Description Resetting the power computation reading causes the log to report time at which it is reset. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8508 Message New power budget ( arg1 W AC) may permit future degradation of redundancy.
Recommended Response Action The server power priority can be changed once Server Based Power Management mode is disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power > Configuration page, then uncheck the Enable Server Based Power Management checkbox. Retry the operation.
Detailed Description Unable to set the CHASSIS_POWER_button_disable chassis power property. Recommended Response Action Retry the operation. If the issue persists, contact your service provider.
Detailed Description The user account credentials provided for this chassis power action do not have the correct privilege. Chassis control privilege is required to perform chassis power actions. Recommended Response Action Retry to action with a different user account that has chassis power control privilege.
Detailed Description Unable to perform the chassis power action requested. Recommended Response Action Check the tracelog for more information. If the issue persists, contact your service provider.
PWR8518 Message Unable to perform the chassis power action because the chassis is already turned on. Detailed Description Unable to perform the chassis power action because the chassis is already turned on. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8520 Message Initiated the chassis reset operation. Detailed Description The chassis reset operation was initiated. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8522 Message Initiated chassis power cycle operation. Detailed Description The chassis power cycle operation was initiated. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8524 Message Redundancy was lost, while Server Performance Over Power Redundancy is enabled. Detailed Description The redundancy was lost because the power requirement of the chassis exceeds the current redundant policy. Recommended Response Action No response action is required. Review the power requirements and determine if more PSUs are needed to restore redundancy.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8526 Message 110VAC Operation unacknowledged. Detailed Description 110VAC operation of PSUs is unacknowledged. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8528 Message Unable to set Max Power Conservation Mode because the Server Based Power Management mode is enabled. Detailed Description The Max Power Conservation Mode can be enabled only when Server Based Power Management Mode is disabled. Recommended Response Action The Max Power Conservation Mode can be changed when Server Based Power Management mode is disabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8530 Message Max Power Conservation Mode is disabled. Detailed Description Max Power Conservation Mode is disabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8532 Message Server Based Power Management Mode is disabled. Detailed Description Server Based Power Management Mode is disabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8534 Message Unable to set Server Based Power Management Mode to enable. Detailed Description Unable to set Server Based Power Management Mode to enable. Recommended Response Action Retry the operation. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* 1153
RAC Event Messages 46 RAC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
RAC003 Message Missing required parameter arg1 . Arguments arg1 = parameter name Detailed Description One or more required parameters for the method are missing. Recommended Response Action Refer to the profile document and provide the required parameters. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC004 Message Invalid parameter value for arg1 .
RAC006 Message The attribute value cannot be changed because it is of read-only type. Detailed Description The attribute value cannot be changed because it is of read-only type. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC007 Message The attribute value is outside the acceptable range. Detailed Description The attribute value is outside the acceptable range.
Detailed Description The requested operation cannot be completed because the length of the input string exceeds maximum length allowed. Recommended Response Action Verify the string length and retry the operation. Refer to the Lifecycle ControllerRemote Services documentation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC010 Message Input contains invalid character.
Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0102 Message The Smart Card Logon plug-in is not installed. Install the plug-in from the iDRAC Web GUI to log in using Smart Card. Detailed Description The software to communicate with the Smart Card is not loaded in this browser. Smart Card can be used for log in only if the appropriate Smart Card software is installed in the browser.
No alerts are applicable for this message RAC0105 Message The Smart Card reader cannot be detected. Check whether the reader is installed correctly. Detailed Description Communication with the Smart Card reader cannot be established, or is lost. Recommended Response Action This error may occur because: 1. Check connection between reader and system. 2. There may be an issue with the Smart Card reader. Try reinstalling the reader driver or use a different reader.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0108 Message An internal error is encountered. Insert a valid Smart Card and try again. (Does this and preceding messages show up in the SEL?) Detailed Description A non-specific error is detected when accessing the Smart Card. Recommended Response Action Review the error message preceding or following this message.
RAC0115 Message The Destination IP Address value is invalid. Detailed Description The IPv4 address does not conform to the addressing standard or the supported IPv4 address range. Recommended Response Action Enter the Destination IP Address value between [1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)]. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0116 Message Invalid Destination IPv6 Address.
Detailed Description The SD card is not a valid vFlash SD card. The use of non-Dell media prevents the use of some extended capabilities and functions. Recommended Response Action Insert a supported vFlash SD card. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC012 Message Unable to perform the operation because of insufficient user privileges.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0124 Message Invalid label: Label must be exclusively alphanumeric characters. Detailed Description All characters in the label must be alphanumeric. Recommended Response Action Enter all alphanumeric characters. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0126 Message The label value is invalid. Expected range: 1-6 alphanumeric characters.
RAC0128 Message An error has occurred in vFlash. Detailed Description A non-specific error has been detected while accessing the vFlash. Recommended Response Action Try the operation again in a few minutes. If the problem persists, reset iDRAC before trying the operation again. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0129 Message An error has occurred while initializing the SD card.
Detailed Description A separate message will provide more detail about this error which was detected while creating the vFlash partition. Recommended Response Action No response action is required. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0131 Message An error has occurred while deleting a partition.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0134 Message This operation is unavailable for non-vFlash SD cards. Detailed Description The SD card is not a valid vFlash SD card. The use of non-Dell media prevents the use of some extended capabilities and functions. Recommended Response Action Insert a valid vFlash SD card.
RAC0137 Message An error has occurred while changing the read-write state for the partition. Detailed Description A separate message will provide more detail about this error which was detected while changing the read-write state of the vFlash partition. Recommended Response Action No response action is required. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0138 Message A valid certificate is not loaded.
Detailed Description The firmware update process returned an Update Failed status. Recommended Response Action Try the firmware update again in a few minutes. If the problem persists, try uploading the firmware through another interface such as Web GUI, RACADM, or DUPs. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0141 Message Firmware update verification failed: The update status is unknown.
Recommended Response Action Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0147 Message Rollback firmware is not available. Detailed Description Firmware rollback image is missing or is corrupt. Recommended Response Action Upload a new firmware image.
RAC015 Message Unable to run the method because the input value is not one of the possible values for AttributeName arg1 . Arguments arg1 = attribute name Detailed Description The input attribute value is not valid for the attribute identified in the message. Recommended Response Action Provide valid attribute value for the attribute identified in the message and retry the operation.
RAC0152 Message Unable to retrieve the power supply information. The system is powered off. Detailed Description While the system is powered off it is unable to retrieve information about power supplies. Recommended Response Action Turn the system on to view this information. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0153 Message Non-redundant power mode: Check the system hardware manual for implications.
Detailed Description While the system is powered off it is unable to retrieve information about system temperature. Recommended Response Action Turn the system on to view this information. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0156 Message Unable to retrieve the voltage information. The system is powered off. Detailed Description While the system is powered off it is unable to retrieve information about system voltage.
Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC016 Message Unable to run the method because an invalid attribute name is entered. Detailed Description The method cannot be run because an invalid attribute name is entered. Recommended Response Action Enter a valid attribute name and retry the operation.
RAC017 Message Job created to apply the attribute value. Detailed Description The requested job has been created. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0171 Message Certificate upload failed: Certificate has expired. Detailed Description Certificate upload failed because the certificate has expired. Recommended Response Action Certificate has expired.
Detailed Description Certificate upload failed. Unable to get local issuer certificate. The local issuer certificate is the certificate for the Certificate Authority (CA) that has signed the certificate for the Active Directory (AD) server, unless it is self signed. The iDRAC needs to verify that the CA is legitimate. Recommended Response Action Certificate has expired. Try creating a new CSR and then upload the certificate.
Recommended Response Action Upload a valid certificate. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0207 Message Certificate upload failed. Detailed Description Certificate upload failed possibly due to poor network connection. Recommended Response Action Try the operation again in a few minutes. If the problem persists, issue a new Certificate Signing Request (CSR) and try again.
RAC021 Message Unable to set static values for IPAddress Net mask or Gateway because DHCP is Enabled. Detailed Description The static values for IPAddress Net mask or Gateway cannot be set because DHCP is enabled. Recommended Response Action Disable DHCP to set static values for IPAddress Net mask or Gateway. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0211 Message Firmware update has failed.
Detailed Description Login page is missing a username. Recommended Response Action Enter a valid username. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0214 Message Missing Password. Detailed Description Login page is missing a password. Recommended Response Action Enter a valid password.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0217 Message iDRAC is not responding. Detailed Description Client did not receive a response for the login request. Recommended Response Action Try pinging the iDRAC and then try again. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0218 Message The maximum number of user sessions is reached.
RAC022 Message Unable to set values for User Password, IPMILan, IPMISerial or User Admin Privilege because the User Name is not configured. Detailed Description Unable to set values for User Password, IPMILan, IPMISerial or User Admin Privilege because the User Name is not configured. Recommended Response Action Set User Name before attempting to set values of other identified attributes.
Detailed Description The Subject line in the email contains invalid characters. Recommended Response Action Invalid character. Enter a valid value as mentioned in the online help. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0224 Message Invalid e-mail description. Detailed Description A partial string used to construct a complete error message. Recommended Response Action Enter a valid email description.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0227 Message SD card is not detected: Insert an SD Card of size greater than 256MB. Detailed Description The SD card is not present, or communication with the SD card is lost. This could result in reduced functionality and capabilities. Recommended Response Action This error may occur because: 1. Make sure the SD card is seated correctly. 2. The SD card is invalid.
RAC0230 Message This operation erases all data in the SD Card. Do you want to continue? Detailed Description This message is displayed when a confirmation is required to initialize the vFlash SD Card. Recommended Response Action Press OK to initialize the SD Card. This will erase all data. If undesired press Cancel. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0231 Message This operation erases all data in the partition.
Detailed Description vFlash image upload failed because the image is not valid. Recommended Response Action Image may be corrupt. Try uploading a valid vFlash image. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0237 Message An error occurred while uploading the vFlash image. Detailed Description A separate message will provide more detail about this error which was detected while uploading the vFlash image.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC024 Message Unable to VLAN is Disabled so cannot set VLAN Priority because VLAN is Disabled. Detailed Description Unable to VLAN is Disabled so cannot set VLAN Priority because VLAN is Disabled. Recommended Response Action Enable VLAN to set VLAN Priority. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0240 Message vFlash is disabled.
RAC0242 Message The selected partition does not exist. Detailed Description The vFlash partition does not exist. This may be due to another user deleting that partition. Recommended Response Action Refresh the Web GUI page to see the available partitions. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0243 Message Partition failed: A partitioning conflict has occurred with another session.
Detailed Description The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed. Recommended Response Action Try the operation after a few minutes or with another partition. If the problem persists, reset iDRAC and repeat the operation. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0246 Message Partition is read-only.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0249 Message One or more partitions are in-use by another process. Detailed Description The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed. Recommended Response Action Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation.
RAC0251 Message One or more partitions are currently attached. Detailed Description The vFlash partitions are attached. Therefore, the current operation cannot proceed. Recommended Response Action Detach the partitions and try again. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0252 Message One or more partitions are currently detached.
Detailed Description This error message is displayed to indicate that the IPv4 Gateway Address does not conform to the required format Recommended Response Action Enter a valid Gateway Address. Expected range: [0.0.0.0 or 1.0.0.0 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)]. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0255 Message The Subnet Mask is invalid. Expected ranges are: 255.XXX.0.0 [Class A], 255.
Detailed Description This error message is displayed to indicate that the Alternate DNS IPv4 address does not conform to the required format. Recommended Response Action Enter a valid Alternate DNS Server Address. Expected range: [0.0.0.0 or 1.0.0.0 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)]. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0259 Message Invalid IPv6 address.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0261 Message Invalid IPv6 gateway address. Detailed Description This error message is displayed to indicate that the IPv6 gateway address does not conform to the required format. Recommended Response Action Enter a valid IPv6 gateway address.
RAC0265 Message Specify the VLAN ID and VLAN Priority. Detailed Description If VLAN is enabled, specify the VLAN ID and VLAN Priority. Recommended Response Action Enter a VLAN ID and VLAN Priority. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0266 Message Invalid VLAN ID. Expected range: 1-4094. Detailed Description Specify a valid VLAN ID. Recommended Response Action Enter a valid VLan ID. Expected range: 1-4094.
Detailed Description The NIC is disabled. This may adversely affect the current operation, and might not allow subsequent GUI interactions to this NIC. Recommended Response Action Enable the NIC before performing the operation. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0269 Message The NIC MTU is invalid. Expected range: 576-1500 or 0x240-0x5DC. Detailed Description Specify a valid NIC MTU.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0271 Message Continuing will lock user account. Detailed Description Locking the user account prevents them from gaining access to iDRAC. Recommended Response Action Press OK to lock this user account. This action will prevent future access for this user. If undesired press Cancel.
RAC0274 Message See the iDRAC user documentation for more information on using the Racadm utility or the serial interface. Detailed Description If the Enable NIC checkbox is cleared, remote access to iDRAC is disabled. Recommended Response Action See iDRAC user documentation for more information on using racadm. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0275 Message Click OK to disable the NIC.
Detailed Description This warning message appears when IPv4 is disabled. Recommended Response Action Use IPv6 network to access iDRAC remotely. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0278 Message Disabling IPv6 prevents access to iDRAC using an IPv6 address. Detailed Description This warning message appears when IPv6 is disabled. Recommended Response Action Use IPv4 network to access iDRAC remotely.
Recommended Response Action Set DHCP attribute to Enable to be able to Enable DNS Domain Name From DHCP or DNS From DHCP. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0280 Message The IP Range Address is invalid. Expected range: 0.0.0.0 - 255.255.255.255. Detailed Description This error message is displayed to indicate that the IPv4 address does not conform to the required format.
RAC0283 Message IP Blocking Fail Window is invalid. Expected range: 10-65535. Detailed Description This is the time span (in seconds) within which IP Blocking Fail Count failures must occur to trigger the IP Blocking Penalty Time. The default value is 3600 seconds (1 hour). Recommended Response Action Enter a valid IP Blocking Fail Window. Expected range: 10-65535.
Detailed Description When creating a user account, the New Password and Confirm New Password fields cannot be empty. Recommended Response Action Enter valid passwords for New Password and Confirm New Password. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0288 Message Invalid entry: Entry must be exclusively alphanumeric characters and valid symbols.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0290 Message The user name cannot have spaces. Detailed Description The user name value does not accept spaces. Recommended Response Action Do not enter spaces in the user name. If desired, use underscores. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0291 Message The user name cannot contain: /, \, @, .
RAC0293 Message When certificate validation is enabled, a valid root Certificate Authority (CA) certificate must be uploaded. The CA certificate is used to verify the directory server SSL certificate. Detailed Description This error is displayed when LDAP or Active Directory cannot find an associated Certificate Authority (CA) certificate. Recommended Response Action Upload a valid root Certificate Authority (CA) certificate.
RAC0297 Message Specify a Domain Controller Address must be configured. Detailed Description The Domain Controller Address be specified for Active Directory configuration. Recommended Response Action Enter a valid Domain Controller Address. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0298 Message Root Domain Name must be configured. Detailed Description A Root Domain Name must be specified for Active Directory configuration.
Detailed Description User will be unable to connect to Remote File Share. Recommended Response Action Make sure proper connectivity exists between the client and the remote file share before using this feature. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0302 Message iDRAC Express does not support this feature. Detailed Description This error message is displayed when iDRAC does not have a valid Enterprise license.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC031 Message Unable to complete the operation because an incorrect username is entered. Detailed Description The operation cannot be completed because an incorrect username is entered. Recommended Response Action Enter a valid username and retry the operation.
RAC034 Message Unable to create a job because the job queue is full. Detailed Description The job queue is full. Recommended Response Action Wait for existing jobs to run to completion or delete some jobs from the job queue. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC035 Message No pending configurations. Detailed Description There are no pending values for the any of the iDRAC attributes.
Detailed Description There are no pending configurations to delete. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC038 Message Unable to perform the operation due to an unknown error in iDRAC. Detailed Description The operation did not complete successfully because of an unknown error in the iDRAC. Recommended Response Action Retry the action.
Recommended Response Action Verify that all required parameters are provided. Refer to the Lifecycle ControllerRemote Services documentation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0400 Message iDRAC memory low. Detailed Description iDRAC is running low on memory. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC041 Message The set operation on the event filters failed. Detailed Description The event filters set operation did not complete successfully due to invalid input parameters. Recommended Response Action Verify the specified input parameters and retry the operation.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC044 Message Unable to update some event filter settings. Detailed Description Some event filter settings were not updated due to problems encountered processing the input parameters. Recommended Response Action Verify the input parameters provided and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation.
RAC047 Message Unsupported event action for the specified event filter. Detailed Description The event action selected is not supported for the event filter specified. Recommended Response Action Refer to the iDRAC User Guide and Lifecycle Controller documentation and retry the operation with a valid event action selection on the specified filter.
Detailed Description The country code is not entered in the correct format or does not exist. Refer to ISO 3166 for the correct country code format. Recommended Response Action Enter country code in the correct format as defined in ISO 3166. For example, United States = US. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0500 Message There are no batteries to be displayed. Detailed Description Batteries cannot be displayed.
Recommended Response Action 1. Check if the host system is powered off or shutdown. 2. Check if virtual disks are created. Category Storage (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0503 Message There are no out-of-band capable controllers to be displayed. Detailed Description Out-of-band controllers cannot be displayed. This error may occur if the host system is powered off, or controllers are removed or disconnected.
No alerts are applicable for this message RAC0506 Message You do not have privileges to perform this operation. Detailed Description This error occurs when the user tries to access a program or function that is beyond user granted privileges. Recommended Response Action Contact the system administrator to perform the operation or grant the required privileges.
RAC0509 Message The server is temporarily unavailable. Try again after sometime Detailed Description The server is currently unable to handle the request due to temporary overloading or server maintenance. Recommended Response Action Wait for few minutes and refresh the page. If the issue persists, contact service provider. Category Storage (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC051 Message Unsupported parameter name arg1 .
Detailed Description Physical disks cannot be displayed. This error may occur if the host system is powered off, physical disks are removed, or incorrect filters are applied. Recommended Response Action 1. Check if the host system is powered off or shutdown. 2. Check if the physical disks are inserted into the enclosure or attached to the backplane. 3. Check if correct filters are applied. 4. Check that the Storage Enclosure is on. 5.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0514 Message Unable to create virtual disk(s) on the selected controller. Detailed Description Virtual disk(s) cannot be created because of one or more reasons identified in the Recommended Response Action. Recommended Response Action Check the following: 1) If no physical disk drives are available for virtual disk (VD) creation, install additional physical disk drives.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC052 Message Unable to create a configuration job because an existing configuration job is already in progress. Detailed Description Unable to create a configuration job because an existing configuration job is already in progress. Only one configuration job for a component can run or can be processed at any time.
RAC055 Message User name cannot be cleared because the user account is enabled in the input configuration XML file. Detailed Description The user name for the user account cannot be cleared because the user account is enabled in the configuration XML file. Recommended Response Action Retry the operation after disabling the user account in the configuration XML file.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔ RAC0561 Message iDRAC to CMC communication link is not functioning for agent free monitoring of chassis PCIe slots. Detailed Description iDRAC lost connection with CMC proxy component that enables agent free monitoring of PCIe slots.
RAC0562 Message iDRAC-CMC communication restored for agent free monitoring of chassis PCIe slots. Detailed Description iDRAC automatically restored connection with CMC proxy component. Agent free Monitoring will now be supported for Chassis PCIe slots. Recommended Response Action No response action is required.
Detailed Description The value provided for the specified attribute is not unique. For example, the user name for a user account must be unique. Recommended Response Action Provide a unique value for the specified attribute. For more information about the component being managed, see the DCIM Profile documentation.
Recommended Response Action Power on the server. If the server is already powered on, wait for a few minutes and refresh the page. If the problem persists, contact service provider. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0601 Message Unable to retrieve alert recurrence information. Detailed Description The server encountered an unexpected condition. This may be due to invalid JavaScript Object Notation.
No alerts are applicable for this message RAC0604 Message System inventory may not be up-to-date because Collect System Inventory On Restart (CSIOR) is disabled. Detailed Description The system inventory may not be up-to-date because the Collect System Inventory On Restart (CSIOR) feature is disabled. The CSIOR feature retrieves detailed system inventory information during system startup and stores this information on iDRAC.
RAC0607 Message Unable to perform OS to iDRAC Pass-Through with the current system configuration. Detailed Description The integrated NICs in the system do not support OS to iDRAC Pass-Through. Recommended Response Action Make sure the integrated NICs are enabled from BIOS setup and support OS to iDRAC Pass-Through, then retry the operation. To access BIOS setup, press F2 during system startup. For more information about OS to iDRAC Pass-Through, see iDRAC7 Users Guide.
RAC061 Message Unable to set the IPMI Watchdog because the OS Watchdog is already enabled.. Detailed Description The IPMI Watchdog can not be enabled at the same time as the OS Watchdog. Recommended Response Action Disable the OS Watchdog before enabling IPMI Watchdog. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0610 Message The passphrase and confirm passphrase values entered do not match.
Detailed Description Cancelling the firmware update operation will cancel all firmware updates selected and delete all uploaded firmware files. Recommended Response Action Select Yes to cancel the firmware update operation and delete all uploaded firmware files. Select No to dismiss the message and continue the firmware update operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0613 Message The uploaded file is invalid.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0616 Message Error while extracting custom signing certificate and private key from the PKCS#12 file. Detailed Description iDRAC was unable to continue with the operation after the PKCS#12 file was uploaded, because it is not able to extract the custom signing certificate and private key.
RAC0619 Message The iDRAC firmware rollback will cause an iDRAC restart and all current user sessions will be closed. Detailed Description The message appears in Firmware Rollback page when the iDRAC firmware rollback action completed successfully. Recommended Response Action Reconnect iDRAC communications sessions after iDRAC is restarted. The iDRAC will be ready for login once the restart is complete.
RAC0621 Message Successfully completed the iDRAC firmware update. All current user sessions will be closed. Detailed Description The message appears in Job Queue page when the iDRAC firmware update job status is completed. Communication to the iDRAC will be lost . Recommended Response Action The iDRAC will be ready for login once the restart is complete.
Detailed Description The requested operation could not be completed, because an incorrect job type or job ID is entered. Recommended Response Action Enter the correct job type or ID, and then retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0625 Message Unable to schedule, because the requested job schedule type is not enabled.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0628 Message Unable to schedule, because the requested recurrent Automatic Update job is already scheduled. Detailed Description The job cannot be scheduled, because the requested recurrent Automatic Update job is already scheduled. Recommended Response Action Delete the current scheduled job, and then retry to create a new Automatic Update job with a new schedule.
No alerts are applicable for this message RAC0630 Message Unable to schedule, because an invalid network file share type is entered. Detailed Description The job cannot be scheduled, because the requested network file share type is not supported. Recommended Response Action Enter a correct network file share type, and then retry the operation.
RAC0633 Message Unable to access the network file share, because an invalid network share password is entered. Detailed Description The requested network file share cannot be accessed, because an invalid password is entered. Recommended Response Action Enter a valid network file share password, and then retry the operation.
RAC0636 Message Unable to access the network file share, because an invalid proxy password is entered. Detailed Description The requested network file share cannot be accessed, because an invalid proxy password is entered. Recommended Response Action Enter a valid proxy password, and then retry the operation.
RAC0639 Message Unable to schedule, because an invalid minute value is entered. Detailed Description The job could not be successfully scheduled, because an invalid value is entered for minute while scheduling a job. Recommended Response Action Enter a correct value from 0 to 59, and then retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC064 Message iDRAC was successfully reset.
Detailed Description The job could not be successfully scheduled, because an invalid value is entered for time while scheduling a job. Recommended Response Action Enter a correct value in the HH:MM format, and then retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0642 Message Unable to schedule, because an invalid value is entered for the day of a month.
Severity Severity 2 (Warning) No alerts are applicable for this message RAC0645 Message Unable to schedule, because an invalid value is entered for the recurrence frequency. Detailed Description The job could not be successfully scheduled, because an invalid value is entered for recurrence frequency while scheduling a job. Recommended Response Action Enter a correct value, and then retry the operation.
RAC0648 Message Unable to process the request. Detailed Description The request cannot be processed, because the length of string entered for one of the input parameter is more than the specified length. Recommended Response Action Enter a string not more than 4095 characters in length, and then retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0649 Message Unable to process the request.
Detailed Description Unable to perform operations on the iDRAC Service Module (iSM) because the iSM is not installed on the server operating system. All fields in the iDRAC GUI iSM page are disabled. Recommended Response Action Make sure that the iDRAC Service Module is installed on the server operating system, and then retry the operation.
Detailed Description The file name cannot be blank when performing the Backup Server Profile operation. Recommended Response Action Enter an appropriate file name, and then retry the operation. Category Audit (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0658 Message The iDRAC Service Module service can now be manually started on the server operating system.
Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0660 Message Unable to access the specified file server location. Detailed Description The file server cannot be accessed because of incorrect credentials. Recommended Response Action Check the file server credentials and retry the operation.
creating new virtual disks. To remove foreign data, perform an initialization operation. Recommended Response Action Press OK to continue. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0663 Message Resetting the selected PERC controllers configuration will delete all the virtual disks (VDs) and unassign hot-spares from the associated controller.
Detailed Description RAID Controller Log data is being collected. This operation will take less than the number of minutes identified in the message. Recommended Response Action Do not log off from the application until the log data collection process is completed. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0666 Message A RAID Controller Log is created. Detailed Description A RAID Controller Log is created.
Detailed Description This setting will be applied during the next server restart. If the setting is not compatible with the RAID Controller, then LED status indicators on all the associated hard disk drives (HDDs) stop functioning. Recommended Response Action Press OK to continue. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0669 Message Initializing the virtual disk will permanently delete data from the virtual disk.
Recommended Response Action If the specified virtual disk is a boot device, the server will not boot. Press OK to continue. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0671 Message Going out of this page will not save the operations or configuration settings that were selected. Detailed Description Going out of this page will not save the operations or configuration settings that were selected.
RAC0674 Message Export Report will create a zip file of XML and text-based logs intended for Dell Technical Support assistance with troubleshooting system issues. Choose Advanced Export Options to specify optional report settings and actions. Detailed Description Export Report will create a zip file of XML and text-based logs intended for Dell Technical Support assistance with troubleshooting system issues. Choose Advanced Export Options to specify optional report settings and actions.
Recommended Response Action Do one of the following and retry the operation: 1) If there are no disk drives available in ready state, insert additional disk drives and make sure the drives are in ready state. 2) If no virtual disks are present, click and create at least one virtual disk. 3) If the physical disk drive(s) are in non-RAID mode, convert them to RAID mode by pressing Ctrl+R while restarting the server, and then select the required controller.
RAC0679 Message A job operation is already running. Retry the operation after the existing job is completed. Detailed Description Unable to process the request because a job operation is already running. Recommended Response Action Wait until the running job is completed or delete the scheduled job and retry the operation.
Recommended Response Action Reset the iDRAC user credentials and BIOS passwords to default and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0681 Message Shared component updates through the Server OS or Lifecycle controller cannot be applied because the CMC setting for Chassis Management at Server Mode is not set to Manage and Monitor.
RAC0683 Message Unable to perform split mode configuration on enclosure(s). Detailed Description Unable to perform split mode configuration on enclosure(s). Recommended Response Action Check the following: 1) The controller must have Real Time Configuration Capability and the associated enclosure(s) must have Split Mode Capability in order to perform the operation. 2)The controller(s) associated with the enclosure(s) support real time configuration.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0686 Message Some of the applied pending operations were not created. Detailed Description Some of the applied pending operations were not created. Recommended Response Action View successful pending operations by clicking the Pending Operations button.
No alerts are applicable for this message RAC0689 Message Unable to create a virtual disk on the selected disk drives, because Lifecycle Controller is not enabled. Detailed Description Unable to create a virtual disk on the selected disk drives, because Lifecycle Controller is not enabled. Recommended Response Action To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup.
Detailed Description The iDRAC Service Module is not installed on the operating system of the server. Recommended Response Action Install the iDRAC Service Module and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0692 Message Unable to assign and un-assign physical disk drives as global hotspare(s), because Lifecycle Controller is not enabled.
Recommended Response Action To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes. Retry the operation after the server has restarted.
Recommended Response Action Do one of the following: 1) Click Pending Operations button to view pending operations. 2) Click Create Job button to create a configuration job. 3) Click Cancel button to quit job creation. Category Configuration (RAC = RAC Event) Severity Severity 1 (Critical) No alerts are applicable for this message RAC0698 Message Unable to modify USB management settings because the USB device is currently in use.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0700 Message Email page successful to arg1 . Arguments arg1 = email address Detailed Description An email page was successfully sent. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0702 Message Requested system powercycle. Detailed Description Requested system powercycle. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0704 Message Requested system powerdown. Detailed Description Requested system powerdown. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0706 Message Requested system NMI. Detailed Description Requested system NMI. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0708 Message Previous reboot was due to a firmware watchdog timeout. Detailed Description Previous reboot was due to a firmware watchdog timeout. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC071 Message Unable to perform the iDRAC reset operation because the firmware upgrade operation is in progress. Detailed Description The iDRAC reset operation cannot be completed because a firmware upgrade operation is in progress. Recommended Response Action Wait for the current update process to complete and retry the operation.
RAC0711 Message Unknown power on response from the CMC. Detailed Description Unknown power on response from the CMC. Recommended Response Action Try resetting the CMC. Also try resetting the server.
RAC0713 Message Server failed to power up due to fabric mismatch. Detailed Description Server failed to power up due to fabric mismatch. Recommended Response Action Ensure that the hardware compatibility between the IO Module (IOM) and the Mezzanine (Mezz) card is correct. Check the M1000e Hardware Manual for correct component compatibility.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0715 Message Image file does not exist in the given remote share path. Detailed Description Image file does not exist in the given remote share path. Recommended Response Action Ensure that the image file is available on the share path provided. Retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0717 Message Remote share unmounted successfully. Detailed Description Remote share unmounted successfully. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0719 Message Not able to connect to remote file share. Virtual media devices are already in use. Detailed Description Not able to connect to remote file share. Virtual media devices are already in use. Recommended Response Action Stop existing Virtual Media sessions and retry the operation.
Arguments arg1 = sharename Detailed Description Unable to mount remote share. Recommended Response Action Retry the operation. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RAC0721 Message Remote share mounted successfully arg1 .
RAC0722 Message Failed to program the Chassis assigned MAC address for the NIC.Integrated. arg1 . Arguments arg1 = NDC slot number Detailed Description Failed to program the Chassis assigned MAC address for the NIC.Integrated in the specified slot number. Recommended Response Action Reseat the server and retry.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0724 Message Quick Sync Firmware is successfully updated. Detailed Description Quick Sync Firmware is successfully updated. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0726 Message Auto-throttling is disabled for the server. Detailed Description Auto-throttling is disabled for the server based on a request from the Chassis Management Controller (CMC) because the CMC is restarting.. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0728 Message The Quick Sync communication is no longer functioning. Detailed Description The Quick Sync communication or the connection to the iDRAC is no longer functioning. Recommended Response Action Do the following: 1) Remove and reseat the bezel. 2) Turn the bezel on by pressing the activation button. 3) Try the Quick Sync feature again. If the issue persists, contact your technical support provider.
RAC074 Message Unable to perform the iDRAC reset to factory defaults operation because a vFlash partition creation operation is in progress. Detailed Description The iDRAC reset to factory defaults operation cannot be completed because a vflash partition creation operation is in progress. Recommended Response Action Wait for the vFlash partition creation process to complete and retry the operation.
RAC0742 Message The Secure Erase command will be executed on the selected PCIe SSD disk drives(s) only after the reboot of the system or loss of power to the disk drives(s). Detailed Description A Secure Erase operation on a PCIe SSD overwrites all blocks in an encrypted way and all the data on the PCIe SSD device will be permanently lost. The changes will happen after reboot of the system or loss of power to the drive. Recommended Response Action Press OK to continue.
RAC0745 Message There are no pending operations present on the selected component group. Detailed Description There are no pending operations on the selected component group. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0746 Message Unable to perform virtual disk (VD) operations, because Lifecycle Controller is not enabled.
RAC0748 Message The BIOS watchdog timer must be disabled if the Automatic System Recovery option is enabled. Detailed Description The BIOS watchdog must be disabled if Automatic System Recovery option is enabled. Recommended Response Action Make sure the BIOS watchdog timer is disabled before enabling the Automatic System Recovery option.
RAC0750 Message Unable to access the USB NIC IP address by using PING process. Detailed Description The USB NIC IP address cannot be accessed by using the PING process. Recommended Response Action Enter another appropriate IP address, and then retry the operation.
Severity Severity 2 (Warning) No alerts are applicable for this message RAC0753 Message Reset iDRAC to apply the pending new certificate. Until iDRAC is reset the old certificate will be active. Detailed Description Reset iDRAC to apply the pending new certificate. Until iDRAC is reset old certificate will be active. A manual reset of iDRAC is needed for the new certificate to take into effect. Recommended Response Action Click the Reset iDRAC link to reset iDRAC.
RAC0756 Message Unable to retrieve the fan information. Detailed Description Fan information cannot be displayed. This situation may occur if the server is powered off. Recommended Response Action Power on the server. If the server is already powered on, wait for a few minutes and refresh the page. If the problem persists, contact your service provider.
RAC0759 Message A running Tech Support Report job has been cancelled. Detailed Description A running Tech Support Report job has been cancelled. Recommended Response Action Click Job Queue button to view the status of the cancelled job. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0760 Message Unable to perform physical disk(s) storage configuration operations for the selected controller.
Severity Severity 2 (Warning) No alerts are applicable for this message RAC0762 Message Unable to perform a firmware update because a valid catalog file is not available on the network share. Detailed Description Unable to perform a firmware update because a valid catalog file is not available on the network share. Recommended Response Action Make sure that a valid catalog file is available on the network share and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC0764 Message Selecting a higher SSL encryption enhances the security. However, the cryptography settings for your virtual machine environment (JVM, IcedTea) may require installing the Unlimited Strength Java Cryptography Extension Policy Files to permit usage of iDRAC plugins such as vConsole with this higher level of encryption. NOTE: Using this level of encryption may have import or export implications.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0766 Message Unable to assign USB NIC IP address arg1 to the OSBMC device because only Link Local IP address can be allowed. Arguments arg1 = IP address Detailed Description The USB NIC IP address identified in the message cannot be assigned to the OSBMC device because only Link Local IP address can be allowed.
Recommended Response Action No response action is required. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC RAC0901 Message Invalid syntax. The -t option value must set to 1. Detailed Description The syntax of the specified command is invalid. In this case, the usage of the -t option is invalid.
RAC0903 Message The -d option cannot be used with any other options. Detailed Description The syntax of the specified command is invalid. In this case, the usage of the -d option is invalid. Recommended Response Action See the help text/documentation for valid syntax of the subcommand. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0904 Message The remote file location is not accessible or reachable.
Detailed Description Unable to perform the requested operation. Recommended Response Action Try again later. If the problem persists, contact technical support. Refer to your product documentation to choose the contact method. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0907 Message System ID LED blink on. Detailed Description The System ID LED was successfully set to on.
Severity Severity 2 (Warning) No alerts are applicable for this message RAC0910 Message Invalid subcommand syntax: Specify group and object name. Detailed Description The specified command is missing group and object name syntax. Recommended Response Action Specify the correct subcommand group and object name syntax. See the help text or documentation for the valid syntax.
RAC1000 Message Unable to set the object value for iDRAC IPv6 address or gateway. Detailed Description Unable to set the object value for iDRAC IPv6 Address1 and IPv6 Gateway, because the object IPv6 Autoconfig is enabled. Recommended Response Action Disable the object IPv6 AutoConfig using "racadm set iDRAC.IPv6.AutoConfig <0 | Disabled >", and retry the operation.
RAC1002 Message Active Directory Single Sign On (SSO) cannot be enabled. Detailed Description The Active Directory SSO cannot be enabled, because the object SmartCardLogonEnable is enabled. Recommended Response Action Disable the object SmartCardLogonEnable using "racadm set iDRAC.SmartCard.LogonEnable <0 | Disabled>", and retry the operation.
RAC1004 Message The smart card login cannot be enabled. Detailed Description The smart card login cannot be enabled, because the Active Directory Single Sign On is enabled. Recommended Response Action Disable Active Directory Single Sign On (SSO) using "racadm set iDRAC.ActiveDirectory.SSOEnable <0 | Disabled>", and retry the operation.
RAC1006 Message Unable to process the arg1 , and the update was not applied. Arguments arg1 = file name Detailed Description The update was not applied because of one of the following reasons: 1) The Update Package is invalid. 2) Lifecycle Controller is corrupted. 3) Another update is in progress. Recommended Response Action Do one of the following and retry the operation: 1) Download the correct Update Package from your service provider.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1008 Message The Active Directory object DCLookupByUserDomain cannot be disabled. Detailed Description The Active Directory object DCLookupByUserDomain cannot be disabled, because the Active Directory object DCLookupDomainName is not configured. Recommended Response Action Configure the Active Directory object DCLookupDomainName using "racadm set iDRAC.ActiveDirectory.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1010 Message Unable to set the power cap value. Detailed Description The power cap cannot be set if the object Power.Cap is disabled. Recommended Response Action Enable Power Cap setting using "racadm set System.Power.Cap.Enable < 1 | Enabled >", and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1012 Message Unable to change the auto-negotiation state for the current NIC selection mode. Detailed Description Unable to change the auto-negotiation state for the current NIC selection mode, because the iDRAC NIC is in dedicated mode.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1014 Message The SNMPv3 privacy protocol cannot be configured to AES or DES mode if SNMPv3 authentication protocol state is set to "None". Detailed Description The SNMPv3 privacy protocol cannot be configured to AES or DES mode if SNMPv3 authentication protocol state is set to "None".
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1017 Message Successfully modified the object value and the change is in pending state. Detailed Description Any staged operation requires a job and system reboot to apply the object values. Recommended Response Action To apply modified value, create a configuration job and reboot the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1019 Message The specified object is not supported for the current system configuration. Detailed Description Some objects have dependencies on other objects that are required to perform a task. The specified object is not available because of such dependencies.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1021 Message NIC objects are not available in the current system configuration. Detailed Description NIC objects are not available if NIC devices are not installed in the system, or if some iDRAC services are busy.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1024 Message Successfully scheduled a job. Detailed Description The pending value is applied during the next reboot of system. Recommended Response Action Verify the job status using "racadm jobqueue view -i JID_xxxxx" command.
Recommended Response Action Verify the object dependency using "racadm help ..", and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1026 Message A custom signing certificate does not exist.
Recommended Response Action Verify if the alerts were received by the configured destination. Otherwise, reconfigure the destination and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1028 Message Unable to download the specified certificate type.
Recommended Response Action Make sure to specify "3" for the certificate type (-t) option, and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1030 Message The custom signing certificate was deleted.
Recommended Response Action Verify if iDRAC has a custom signing certificate. If it has the certificate, retry the operation. If the issue persists, contact your service provider. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1032 Message arg1 jobs was cancelled by the user.
Recommended Response Action Make sure to enable Collect System Inventory On Restart (CSIOR) feature, reboot the server, and retry the operation. If CSIOR is already enabled, restart iDRAC using "racadm racreset" command, and retry the operation.
Detailed Description The command is unable to clear the pending state for attributes of the specified component because there are no pending values. Recommended Response Action Make sure that there is at least one attribute on the specified device has a pending value, and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC1036 Message Successfully cleared pending attribute(s) for the group specified.
RAC1038 Message Unable to clear pending values for the specified component. Detailed Description Unable to clear pending values for the specified component. This may be because there is an existing configuration job for the component. Recommended Response Action Make sure that a config job is not scheduled for this component. For more information, view the help command by running the RACADM command "racadm jobqueue help delete".
RAC1040 Message Successfully accepted the RAID storage configuration operation. The change is in pending state. Detailed Description The requested RAID storage operation was successfully accepted and now must be applied by creating a RAID storage configuration job. Recommended Response Action To apply the configuration operation, create a configuration job, and then restart the server. To create the required commit and reboot jobs, run the jobqueue command.
Recommended Response Action For more information, view the help details by running the RACADM command "racadm help autoupdatescheduler". Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1043 Message Unable to configure the Automatic Update (autoupdate) feature settings.
Detailed Description The Automatic Update (autoupdate) feature is not enabled Recommended Response Action To enable, run the RACADM command "racadm set lifecyclecontroller.lcattributes.autoupdate 1". Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1045 Message Specifying ftp.dell.
RAC1046 Message Unable to view the Automatic Update (autoupdate) feature settings because the feature has not been configured. Detailed Description Unable to view the Automatic Update (autoupdate) feature settings because the feature has not been configured. Recommended Response Action Configure the Automatic Update feature by running the RACADM command "racadm autoupdatescheduler create" with the desired option settings.
RAC1048 Message Unable to clear the Automatic Update (autoupdate) feature settings because there is currently no configuration. Detailed Description The Automatic Update (autoupdate) feature settings must already exist in order to be cleared. Recommended Response Action No response action is required.
RAC1050 Message Unable to configure the Automatic Backup (autobackup) feature settings. The required options are either invalid or not provided. Detailed Description One or more required options to configure the Automatic Backup (autobackup) feature are missing. Recommended Response Action For more information, view the help details by running the RACADM command "racadm help systemconfig backup".
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1052 Message The Automatic Backup (autobackup) feature is not enabled. Detailed Description The Automatic Backup (autobackup) feature is not enabled. Recommended Response Action To enable, run the RACADM command "racadm set lifecyclecontroller.lcattributes.autobackup 1".
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1054 Message Successfully cleared the Automatic Backup (autobackup) feature settings. Detailed Description Successfully cleared the Automatic Backup (autobackup) feature settings.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1056 Message Rollback operation initiated successfully. Detailed Description The requested firmware Rollback operation was initiated successfully.
RAC1058 Message Rollback operation did not complete successfully because Lifecycle Controller is disabled. Detailed Description The requested firmware Rollback operation did not complete successfully because Lifecycle Controller is disabled. Recommended Response Action Run the RACADM command "racadm set LifecycleController.LCAttributes.LifecycleControllerState 1" to enable Lifecycle Controller, and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1060 Message System inventory may not be current because the Collect System Inventory On Restart (CSIOR) feature is disabled. Detailed Description The system inventory information may not be current because the Collect System Inventory On Restart (CSIOR) feature is disabled. Recommended Response Action To enable the CSIOR feature, run the RACADM command "racadm set LifecycleController.LCAttributes.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1062 Message Unable to initiate the SystemErase operation. The component identifier specified is not valid. Detailed Description Unable to initiate the requested SystemErase operation. The component identifier specified is not valid. Recommended Response Action Run the RACADM command "racadm help systemerase" to see the list of supported components.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1064 Message Unable to initiate the SystemErase operation because another instance of SystemErase job is already in progress. Detailed Description Unable to initiate the requested SystemErase operation because another SystemErase job is already in progress.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1067 Message Unable to set the minimum non critical threshold value of arg1 , because the value entered is lesser than, or equal to the minimum critical threshold value.
Detailed Description The minimum non critical threshold value identified in the message cannot be set, because the value entered is greater than, or equal to the maximum non critical threshold value. Recommended Response Action Check the maximum non critical threshold level using an appropriate RACADM command. For example, to view the maximum non critical threshold value of a sensor, run the racadm getsensorinfo command at the command line interface, and then retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1070 Message Unable to set the maximum non critical threshold value of arg1 , because the value entered is greater than, or equal to the maximum critical threshold value. Arguments arg1 = System Board Inlet Temp Detailed Description The maximum non critical threshold value identified in the message cannot be set, because the value entered is greater than or equal to the maximum critical threshold value.
and then retry the operation. For more information about other RACADM commands, run the racadm help command.
RAC1073 Message Unable to reset the threshold value of sensor arg1 because the capability to reset this sensor threshold value is not supported. Arguments arg1 = sensor name Detailed Description The threshold value of the sensor identified in the message cannot be successfully set because the capability reset the sensor threshold value is not supported. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1110 Message Unable to run the command, because an incorrect Proxy port number was entered. Detailed Description Unable to run the command, because an incorrect Proxy port number was entered. The Proxy port value must be a positive integer. Recommended Response Action Enter only numbers for a Proxy port value.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1112 Message Unable to delete the pending values for the specified device because the iDRAC internal storage is in use by a currently running job. Detailed Description Unable to clear the pending state from the attributes for a RAID object. A job is currently running and iDRAC internal storage is in use. Recommended Response Action Retry the operation after any currently running jobs have completed.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1114 Message Configuration XML file preview operation job is initiated. Job ID = arg1 Arguments arg1 = job ID Detailed Description The configuration XML preview operation was successfully initiated and has generated a job with the job ID identified in the message. Recommended Response Action Monitor the status of the preview operation job by running the racadm command "racadm jobqueue view -i ".
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1116 Message Unable to run the command, because the restart flag entered is incorrect. Detailed Description The command could not be successfully run, because an incorrect "restart flag" value was entered in the command. Recommended Response Action Enter a correct flag value. The recommended values are "true" and "false". Make sure that you have entered the correct value, and then retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1118 Message Successfully initiated the update operation specified in the command. Detailed Description Successfully initiated the update operation specified in the command. Recommended Response Action To know about the status of a command that is initiated, run the following command: racadm jobqueue view -I .
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1120 Message Unable to run the command, because an incorrect Proxy type is entered. Detailed Description The command could not be successfully run, because an incorrect Proxy type value was entered for the -pt option. Recommended Response Action Make sure that you entered either "http" or "https" as the proxy type. Enter the correct type, and then retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1122 Message The specified group or object is not supported on the server. Detailed Description One or more of the group or component attributes specified in the operation do not exist on the targeted server. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1128 Message The -l option must be specified if -u and -p options are used. Detailed Description Any operation involving remote share (CIFS) cannot continue if the location (-l option) is not specified.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1130 Message Unable to complete the operation. This feature is not supported on the currentlyused platform.
Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1132 Message Unable to update the firmware. The value entered for an option is invalid.
Detailed Description The BIOSRTDRequested attribute was modified successfully. The BIOS reset to default values operation is pending a server restart. Recommended Response Action To apply the BIOS default values, restart the server. After the server has restarted, the default BIOS values will be accessible from the iDRAC.
RAC1135 Message Unable to run the RACADM command because an internal instrumentation component has stopped functioning. Detailed Description The RACADM command could not be run because the internal instrumentation components are either busy or have stopped functioning. Recommended Response Action Wait for a minute for the internal instrumentation component to respond, and then retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RAC1137 Message Remote unattended diagnostic results export operation initiated. Detailed Description Remote unattended diagnostic results export operation initiated. Recommended Response Action Using the RACADM command line interface, run the "racadm jobqueue view -i " command to view the status of the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1139 Message The entered option is not supported by the interface. Detailed Description The requested file can be exported from the firmware racadm only to a remote file share. Recommended Response Action Create a remote file share to export the file or use remote or local racadm to export to the file system that is accessible by the racadm executable.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1141 Message The iDRAC firmware rollback operation was initiated. Detailed Description The iDRAC firmware rollback operation was initiated. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1143 Message Configuration results are not applicable for the job type for Job: arg1 . Arguments arg1 = job ID Detailed Description The job identified in the message is not a configuration job, a configuration XML import or preview type job that generates configuration results. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1145 Message The entered log type is invalid. Detailed Description The value entered for the -t option is invalid. Recommended Response Action Check help text for the list of valid log types and retry the operation by entering a valid log type.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1147 Message Unable to set the SNMPv3 username entered in the command because the username is not present or enabled on iDRAC. Detailed Description The SNMPv3 user cannot be set because the user with the entered username for the SNMPv3 group is not present or enabled on iDRAC.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1151 Message The export operation is unsuccessful. Detailed Description The export operation did not complete successfully. Recommended Response Action Run the RACADM techsupreport collect command again and then retry the export operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1153 Message The time stamp is not available to display. Detailed Description The time stamp was not recorded for the previous techsupreport collect operation. Recommended Response Action Run the RACADM techsupreport collect command.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1155 Message Unable to complete the operation because Lifecycle Controller is disabled. Detailed Description The operation was not completed because Lifecycle Controller is disabled. Recommended Response Action Enable the Lifecycle Controller and retry the operation.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1157 Message Unable to find the specified FQDD. Detailed Description The specified FQDD is invalid. Recommended Response Action Verify whether or not the entered FQDD is valid. Run the command racadm gethostnetworkinterfaces for the list of valid FQDDs.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1159 Message Unable to get the requested data from iDRAC. Detailed Description The data cannot be retrieved from iDRAC because Lifecycle Controller is disabled or a DUP update is in progress.
Detailed Description Unable to set USB group objects because the user account identified in the message does not have the System Control privilege, which is required for this operation. Recommended Response Action Contact the iDRAC system administrator and get the System Control privilege added to the account identified in the message or use account credentials that have System Control privilege and retry the operation.
RAC1162 Message Unable to initiate the techsupreport collect operation for the Tech Support Report (TSR) because another collect operation is in progress. Detailed Description The requested techsupreport collect operation cannot be initiated because another techsupreport collect operation for the Tech Support Report (TSR) is in progress. Recommended Response Action Wait for the current collect operation to complete before initiating another collect operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1164 Message A remote diagnostics operation is currently running and not completed. Detailed Description A remote diagnostics operation is already under execution and another operation can be started only after the current execution is completed. Recommended Response Action Initiate another diagnostics operation only after the currently running operation is completed.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1166 Message Successfully initiated Configuration XML file preview operation that was invoked by arg1 . Arguments arg1 = user name Detailed Description The Configuration XML file preview operation was successfully initiated after it was invoked by the user name identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1169 Message The RACADM "config" command will be deprecated in a future version of iDRAC firmware. Detailed Description The RACADM "config" command will be deprecated in a future version of iDRAC firmware. Recommended Response Action Run the RACADM "racadm set" command to configure the iDRAC configuration parameters.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1175 Message Unable to change the user configuration because modifying the user configuration at index 1 is not allowed. Detailed Description The user configuration cannot be modified, because modification is not allowed at index 1.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1177 Message A USB device is attached to the iDRAC. Detailed Description A USB device is attached to the iDRAC and accessible from the iDRAC. Recommended Response Action No response action is required.
Recommended Response Action Wait until the configuration XML import operation has completed before attempting another operation. Verify the status of the configuration XML import operation by running the RACADM command "racadm jobqueue view".
Detailed Description A USB Device inserted in the front panel USB Management port and is in use by the server operating system. The device needs to not be in use in order to change the port mode settings. Recommended Response Action Remove and reinsert the USB device and retry the operation.
RAC1182 Message Unable to retrieve information for the Power group or attribute because the server is not PMBus capable. Detailed Description The server instrumentation can not provide any information related to power because PMBus capability is not present or the PSU(s) with PMBus capability have been removed. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1184 Message The getuscvresion RACADM subcommand will be deprecated in a future release. Detailed Description The getuscvresion RACADM subcommand will be deprecated in a future release. Recommended Response Action Instead of getuscversion, run the getversion -f lc subcommand.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1186 Message 1000Mbps speed setting is Read Only and cannot be configured for the iDRAC NIC. Detailed Description Only possible configurations for the DRAC NIC are 10Mbps and 100 Mbps. For documentation with respect to this setting, refer to the racadm User Guide under cfgNetTuning group. Recommended Response Action No response action is required.
RAC1188 Message Unable to configure the Upper Non-Critical value for the System Performance sensor. Detailed Description Unable to configure the Upper Non-Critical value for the System Performance sensor because the value provided is not in valid range. Recommended Response Action Specify a value in the range of 0 to 100 to set the upper non-critical value.
RAC802 Message iDRAC time is set using Network Time Protocol. Detailed Description iDRAC time has been set through Network Time Protocol (NTP). Recommended Response Action No response action is required.
Severity Severity 2 (Warning) No alerts are applicable for this message RAC915 Message Unable to change auto-negotiation property for the NIC. Detailed Description The auto-negotiation property for the iDRAC NIC can be changed only if the NIC is in dedicated mode. To change the NIC mode to dedicated, an iDRAC Enterprise license is required. Recommended Response Action Change the NIC mode to dedicated mode by using "racadm set idrac.nic.selection <1 | Dedicated>", and retry the operation.
RAC918 Message Unable to get the inlet temperature data. Detailed Description Racadm unable to obtain the inlet temperature data. This happens if there is no data populated in the temperature tables or if the underlying instrumentation does not return valid values. Recommended Response Action Wait for the underlying instrumentation to populate the thermal tables. Retry the operation.
Detailed Description The file type specified (with the t parameter) is invalid. The temperature history can be exported in XML or CSV. Recommended Response Action Change the requested export file type to either XML or CSV. To do this, change the argument given to the t parameter. The argument given to the parameter is caseinsensitive. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC922 Message Specified path is too long.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC925 Message Recurrence interval is not applicable for this subcategory. Detailed Description An alert recurrence cannot be set for the specified subcategory. The alert recurrence is applicable only to the TMPS subcategory. Recommended Response Action 1. Check if the alert recurrence is applicable to this subcategory. To check this run racadm eventfilters get. 2.
RAC928 Message Unable to modify the recurrence value. Detailed Description Racadm unable to set the recurrence value. This occurs if the underlying instrumentation do not set the value. Recommended Response Action Wait for a few minutes and retry the command. If the problem persists, contact the service provider. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC929 Message Invalid category or subcategory specified.
Detailed Description iDRAC cannot enable or disable the hot spare property, because the system has a non-PMBus PSU. Recommended Response Action No response action is required.
RAC938 Message Successfully initiated configuration XML file export operation invoked by the arg1 . Arguments arg1 = user name Detailed Description The configuration XML file export operation was successfully initiated after it was invoked by the user specified in the message. Recommended Response Action No response action is required.
RAC940 Message Unable to start the system configuration profile export or import operation. Detailed Description If an existing system profile import or export job is running, then a system configuration profile backup or restore operation cannot be started. Recommended Response Action Wait until the existing system profile export or import job is completed or cancel the job before retrying the operation.
RAC942 Message Successfully initiated the import operation. This operation may take several minutes to complete and may cause multiple system restarts while device firmware and configuration are applied. Detailed Description The system configuration profile import operation is initiated. No other operations can be performed on the system while the system configuration server profile is being imported from the system configuration profile.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC944 Message Unable to create the configuration job. Detailed Description A configuration job cannot be created if Lifecycle Controller is disabled. Recommended Response Action Run "racadm set LifecycleController.LCAttributes.LifecycleControllerState 1" to enable Lifecycle Controller, and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC946 Message Unable to set the NIC to Auto Dedicated NIC mode. Detailed Description The "Auto Dedicated NIC" mode cannot be set for a NIC if the NIC selection mode is set to "Dedicated NIC". Recommended Response Action To set the NIC to Auto Dedicated NIC mode, set NIC selection mode to "Shared NIC", and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC948 Message Unable to send the notification for the specified event to the configured destination. Detailed Description A test event notification for the specified message ID was not sent to the configured destination. Recommended Response Action Make sure to the use a valid message ID, set the required notification filter, and retry the operation. If the issue persists, contact your service provider.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC950 Message Unable to add the work note to the Lifecycle Log. Detailed Description The work note cannot be added to the Lifecycle Log if iDRAC is archiving the older records in the Lifecycle Log. Recommended Response Action Wait for several minutes while iDRAC archives the older records, and then retry the operation. If the issue persists, contact your service provider.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC952 Message There is no free space to add new work notes to the Lifecycle Log. Detailed Description The allocated size for the Lifecycle Log entries has reached its maximum limit, and no further work notes can be added to the Lifecycle Log. Recommended Response Action Contact your service provider.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC954 Message The number of characters entered for the comment exceeds the supported limit. Detailed Description Up to 128 characters are allowed for a comment. Recommended Response Action Do not exceed 128 characters for the comment, and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC956 Message There is no free space to add new comments to the Lifecycle Log. Detailed Description The allocated size for the Lifecycle Log entries has reached its maximum limit, and no further comments can be added to the Lifecycle Log. Recommended Response Action Contact your service provider.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC958 Message Unable to start the import or export operation because a job is already running. Detailed Description The import or export operation cannot be started because a job is already running. Recommended Response Action Wait for the currently running job to complete and then retry the operation. The currently running job can be an update, backup, export or other job type.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC960 Message Unable to find the specified configuration XML file for import. Detailed Description The configuration XML file specified for import cannot be located in the specified repository. Recommended Response Action Make sure the specified file name is correct and is located in the specified repository, and retry the operation. For more information about the syntax, run "racadm help set" to view RACADM help.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC962 Message Unable to continue with the operation because Lifecycle Controller is in recovery state, Detailed Description Lifecycle Controller must be enabled to run the operation. Recommended Response Action Enable the Lifecycle controller using the racadm set LifeCycleController.LCAttributes.LifecycleControllerState 1 command, and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC964 Message Unable to perform the operation. Detailed Description The operation cannot be performed because of an internal error. Recommended Response Action Wait for some time before retrying the operation. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC966 Message Unable to continue with the operation because the user name or password is not specified. Detailed Description Any operation involving remote share (CIFS) cannot continue if user name, password, or both are not specified. The u and p options represent the user name and password for the remote share.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC968 Message Importing the configuration XML file from a local share is not supported when using Firmware RACADM. Detailed Description The configuration XML file cannot be imported from a client location when using Firmware RACADM.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC970 Message Incorrect value specified for the end power state option. Detailed Description The import operation cannot continue if the value specified for the end power state of the system option (-s) is incorrect.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC972 Message Insufficient privileges to run the configuration XML file import or export operations. Detailed Description Configuration XML import and export operations require the specified username to have administrator role privileges.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC974 Message Invalid wait time specified. Detailed Description The value specified for the wait time (w) option is invalid. The valid range is 300 to 3600 seconds. Recommended Response Action Make sure to specify a valid wait time (-w) option and retry the command.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC976 Message Export configuration XML file operation initiated. Detailed Description The configuration XML file export operation was initiated. Recommended Response Action Use the racadm jobqueue view i command to view the status of the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC978 Message Unsupported Lifecycle Controller firmware version detected. Detailed Description The Lifecycle Controller firmware version on the target system does not support the configuration XML file import or export operations.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC981 Message The type of certificate specified does not require a passphrase. Detailed Description A passphrase is required only for passphrase protected certificate, which is specified using the value of 3 for the -t option.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC983 Message Invalid passphrase provided for the Public Key Cryptography Standards version 12 (PKCS12) file. Detailed Description The Public Key Cryptography Standards version 12 (PKCS12) file is passphrase protected, and the passphrase provided is invalid.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC985 Message Unable to configure the cfgServerBootOnce object. Detailed Description The object "cfgServerBootOnce" cannot be configured if the object "cfgServerFirstBootDevice" is set to F10, F11, or BIOS value.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC987 Message Firmware update job for arg1 is initiated. Arguments arg1 = file name Detailed Description After initiating the firmware update job, the time taken to complete it depends on size of the update file.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC989 Message Unable to apply the arg1 firmware update. Arguments arg1 = file name Detailed Description Only Windows-based Update Package (.exe extension), iDRAC Firmware (.d7 extension), Personality Module Firmware (.
Detailed Description If Lifecycle Controller is disabled, the firmware update operation cannot continue. Recommended Response Action Enable Lifecycle Controller using the "racadm set lifecyclecontroller.lcattributes.lifecyclecontrollerstate 1" command, and retry the operation.
Arguments arg1 = job ID Detailed Description The job ID specified in the message is invalid or was already deleted. Recommended Response Action To monitor the current set of the jobs, use the "racadm jobqueue view" command.
RAC994 Message Unable to run the "jobqueue delete --all" command. Detailed Description The jobs cannot be deleted if they are in one of these states: "Scheduled" or "Running". However, all jobs in one of these states: "Completed" or "Failed" will be deleted. Recommended Response Action To monitor the job status, use the "racadm jobqueue view -i ", and delete the jobs one at a time using the "racadm jobqueue delete -i " command.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC996 Message Unable to set the object value because the DNS RAC Name object is not configured. Detailed Description Unable to set the specified object value because the object DNS RAC Name is not configured. Recommended Response Action Configure DNS Rac Name using "racadm set iDRAC.NIC.DNSRacName " command, and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC998 Message IPv6 cannot be enabled. Detailed Description IPv6 cannot be enabled if iDRAC NIC is disabled. Recommended Response Action Enable iDRAC NIC using "racadm set iDRAC.NIC.Enable < 1 | Enabled >" command and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC 1399
47 RDU Event Messages RDU0001 Message The fans are redundant. Detailed Description None Recommended Response Action No response action is required.
LCD Message iDRAC Fan redundancy is lost. Check fans. Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC RDU0003 Message Fan redundancy is degraded. Detailed Description One of more fans have failed or have been removed or a configuration change occurred which requires additional fans.
Recommended Response Action Remove and re-install failed fans or install additional fans. Category System Health (RDU = Redundancy) Severity Severity 3 (Informational) Trap/EventID 2475 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC RDU0005 Message The fans are not redundant. Insufficient resources to maintain normal operations.
Detailed Description None Recommended Response Action No response action is required. Category System Health (RDU = Redundancy) Severity Severity 3 (Informational) Trap/EventID 2475 OMSA Event ID 5304 OMSA Trap ID 5304 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ RDU0012 Message Power supply redundancy is lost.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy RDU0013 Message Power supply redundancy is degraded. Detailed Description The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant mode. Recommended Response Action Check the event log for power supply failures.
Trap/EventID 2475 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* RDU0015 Message The power supplies are not redundant. Insufficient resources to maintain normal operations. Detailed Description The system may power down or operate in a performance degraded state.
Recommended Response Action No response action is required Category System Health (RDU = Redundancy) Severity Severity 3 (Informational) Trap/EventID 2475 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* RDU0017 Message The storage power redundancy is no longer available.
Detailed Description The storage system has multiple redundant power lines. One or more of these power lines is no longer available. Recommended Response Action Turn system off and remove AC input power for one minute. Re-apply input power and turn system on. If the issue still persists, contact your service provider. Refer to the product documentation to choose a convenient contact method.
RDU0020 Message Power supply redundancy is disabled. Detailed Description Redundancy is not currently enabled for the power supplies. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RDU0022 Message Fan redundancy is disabled. Detailed Description Redundancy is not currently enabled for the fans. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RDU0030 Message The storage voltage of arg1 is redundant. Arguments arg1 = device name Detailed Description The storage voltage of the device identified in the message is redundant. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* RDU0032 Message The arg1 voltage redundancy is degraded. Arguments arg1 = name Detailed Description The system has multiple redundant voltage lines. One or more of these voltage lines is no longer available.
Recommended Response Action No response action is required Category System Health (RDU = Redundancy) Severity Severity 3 (Informational) Trap/EventID 2475 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* RDU8500 Message CMC arg1 : active Arguments arg1 = slot number Detailed Description The CMC is identified in the me
Arguments arg1 = slot number Detailed Description The Active CMC has detected a problem or a low memory condition. It is waiting for the Standby CMC to reset the Active CMC. Recommended Response Action No response action is required.
RDU8506 Message CMC arg1 : enable failover Arguments arg1 = slot number Detailed Description CMC failover is enabled. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RDU8508 Message CMC arg1 : cannot failover since the other CMC is non-functional. Arguments arg1 = slot number Detailed Description For failover to occur, the standby CMC needs to be present, at the same version as the primary and healthy. During failover, the active CMC resets and the standby CMC becomes active.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* RDU8510 Message CMC arg1 : cannot failover, CMC firmware versions are different Arguments arg1 = slot number Detailed Description For failover to occur, the standby CMC needs to be present, at the same version as the primary and healthy.
Detailed Description For failover, the standby CMC needs to be present, at the same firmware version as the primary CMC and healthy. During failover, the active CMC resets and the standby CMC becomes active. This message is logged when the standby CMC does not meet this criteria Recommended Response Action Check the status of the standby CMC and make sure the firmware version matches the primary CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service provider.
RDU8513 Message CMC arg1 : firmware versions are same arg2 arg3 Arguments arg1 = slot number, arg2 = fw version, arg3 = factory revision Detailed Description The firmware version of Active CMC and Standby CMC are the same. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RDU8515 Message CMC arg1 : failover was initiated by internal health monitoring process. Arguments arg1 = slot number Detailed Description A CMC failover was initiated by the CMC health monitoring process. There should be a reason listed in the chassis log. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* RDU8517 Message CMC arg1 : no action allowed while firmware update is in progress Arguments arg1 = slot number Detailed Description No failover or other action can occur while a CMC firmware update is in progress. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* RDU8519 Message Unable to communicate with peer CMC arg1 . Arguments arg1 = slot number Detailed Description The communication between the primary and standby CMCs was lost.
Recommended Response Action No response action is required. Category Audit (RDU = Redundancy) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* RDU8521 Message CMC arg1 : active CMC has been removed Arguments arg1 = slot number Detailed Description The active CMC has been removed from the chassis.
Detailed Description The standby CMC identified in the message became the active CMC. Recommended Response Action No response action is required.
Arguments arg1 = slot number Detailed Description CMC failover action is not allowed in the current configuration. Recommended Response Action No response action is required.
48 RED Event Messages RED000 Message Unrecognized error code encountered. Detailed Description An unknown error was returned. Recommended Response Action Check the uniform resource identifier (URI) target path and make sure the repository server is available.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RED002 Message Package successfully downloaded. Detailed Description Package has been successfully downloaded. The Job Scheduler will schedule it at the time specified. Recommended Response Action Schedule the job if it is not already scheduled.
Trap/EventID Filter Visibility iDRAC 6211 IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED004 Message The job cannot be run because of an unknown issue. Detailed Description The job cannot be run because of an unknown issue. Recommended Response Action Check the uniform resource identifier (URI), target path and make sure the repository server is available.
Severity Severity 2 (Warning) Trap/EventID 6210 Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ iDRAC ✔ CMC ✔* WS Eventing ✔ CMC LC Log Remote System Log LCD ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RED006 Message Unable to download Update Package. Detailed Description The Update Package cannot be successfully downloaded. Recommended Response Action Check the network connection and access to the update package from the iDRAC.
Category Updates (RED = FW Download) Severity Severity 2 (Warning) Trap/EventID 6210 Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ iDRAC ✔ CMC ✔* WS Eventing ✔ CMC LC Log Remote System Log LCD ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RED008 Message Unable to extract payloads from Update Package. Detailed Description The firmware payloads in the Update Package cannot be extracted.
Recommended Response Action Verify if Lifecycle Controller is installed on the system by pressing F10 on boot up. If the Lifecycle Controller application is not present, use the update package to reinstall it.
Detailed Description The firmware was rolled back to the previous version. Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) No alerts are applicable for this message RED011 Message USC version is not compatible. Detailed Description Current USC version does not support this component. Check InstanceID Recommended Response Action Use the latest version of USC available if possible.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED013 Message The DUP specified is not compatible with the target device. Detailed Description The DUP specified is not compatible with the target device. Recommended Response Action Download and use the DUP that matches the device being targeted.
Severity Severity 2 (Warning) Trap/EventID 6210 Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED015 Message The download protocol specified is not supported. Detailed Description The download protocol specified is not supported.
Recommended Response Action 1. Verify that the path to the share is correct and that the parameters to the call are correct. 2. Verify that there are no network connectivity issues. 3. Verify that the mount point exists.
Detailed Description Reinstall or Rollback not supported for this device. Recommended Response Action 1. Update the device directly using the update methods since rollback is not supported for this device. 2. Verify that the target specified in the command is correct.
RED020 Message Feature not supported on current version of USC. Detailed Description The feature invoked is not supported by the current version of the Unified Server Configurator. Recommended Response Action Upgrade Unified Server Configurator to the latest available version before using this feature.
RED022 Message Version compatibility check was not successful. Detailed Description The version compatibility check of the firmware update package was not successful for the device specified. Recommended Response Action The version compatibility check was not successful for the device specified. Verify that the firmware version pre-requisites specified in the release notes are satisfied.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED024 Message The specified job starts when Lifecycle Controller is available. Detailed Description Lifecycle Controller is in use or currently processing another job. The specified job starts when Lifecycle Controller is available. Recommended Response Action Wait for current Lifecycle Controller task to complete.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED026 Message An internal error occurred while processing updates. Detailed Description An internal error occurred while processing the current update. The update did not complete successfully. Recommended Response Action Retry the current operation.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED028 Message Update files were not selected. Detailed Description Update files were not selected, therefore the installation did not proceed. Recommended Response Action Select one or more update files to install.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC ✔ CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy RED030 Message Reboot is complete. Detailed Description The system reboot is complete. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED032 Message Reached maximum size limit allowed for storing firmware images. Deleted all rollback firmware images. Detailed Description The rollback firmware images previously stored were deleted to provide space for storing the firmware images for the requested operation.
Category Updates (RED = FW Download) Severity Severity 2 (Warning) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy RED034 Message Firmware update in progress. Detailed Description A firmware update operation is currently in progress. Recommended Response Action Check the firmware update job status. Wait for the current job to complete.
Recommended Response Action No response action is required.
RED037 Message All components firmware match with the specified remote repository. Detailed Description The currently installed firmware of the components on the server match with the specified remote repository. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED039 Message Settings for a recurring operation of type arg1 were cleared. Arguments arg1 = operation label Detailed Description Settings for an Automatic Server Profile Backup, Automatic Update, or other recurring operations identified in the message were cleared. The recurring operation identified in the message is deleted. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED041 Message A recurring operation of type arg1 was not created because the required license is not available. Arguments arg1 = operation type Detailed Description The license required to perform the operation identified in the message is expired or is not available.
Detailed Description The necessary user access rights for performing the operation identified in the message are not available for the username used to access the iDRAC. Recommended Response Action Use a username that has the necessary access rights and retry the operation. Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message A recurring task was not created because the required user authority is not present.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED044 Message A recurring operation of type arg1 was unable to create a job because the required license is not available now. Arguments arg1 = operation type Detailed Description The license required to perform the operation identified in the message either has expired or was removed and the iDRAC was unable to create the next job in the sequence.
Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message A recurring task was unable to create a job because the required user authority is no longer present.
RED047 Message A recurring operation arg1 was not created because the operation is already configured. Arguments arg1 = operation type Detailed Description An Automatic Server Profile Backup or Automatic Update operation is already configured. Recommended Response Action Clear the existing configuration settings for the operation identified in the message and retry the operation.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED049 Message The job arg1 is deleted because the recurring operation arg2 is currently not enabled.
Detailed Description The download of the update package was not successful because the user name or password provided to access the network share or the proxy server settings were not correct. Recommended Response Action Check the network connection and access to the update package from the iDRAC. Verify that the user access credentials and proxy server settings are correct.
RED052 Message Processing of update packages is starting. Detailed Description Processing of update packages is starting. Attempting a manual update will not be possible until current update package processing is completed. Recommended Response Action No response action is required.
RED054 Message An update job arg1 was created. Arguments arg1 = job ID Detailed Description A job for applying an update package was created. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED056 Message An internal error occurred. Unable to complete the specified operation. Detailed Description An internal error occurred because of insufficient memory available on iDRAC. Recommended Response Action Retry the operation. If the issue persists, reset the iDRAC and retry the operation.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED058 Message A repository update job arg1 was created. Arguments arg1 = job ID Detailed Description A repository update job with the job ID identified in the message was created. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing ✔ CMC LC Log iDRAC Reset Chassis Event Proxy ✔ CMC RED060 Message The specified repository catalog is not supported. Detailed Description The specified repository catalog is either not supported or the structure is incorrect. Only Windows Update Packages are supported by iDRAC and Lifecycle Controller for the operation.
Category Updates (RED = FW Download) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED062 Message Unable to successfully authenticate user credentials to the specified repository. Detailed Description Unable to successfully authenticate.
Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message IDRAC Updated successfully. Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED064 Message The scheduled Update from Repository job completed successfully. Applicable updates were not found.
RED065 Message The recurring scheduled update from repository job completed and updates were applied. A system restart was not required. Detailed Description The recurring scheduled update from repository job completed and updates were applied. A system restart was not required. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED067 Message The recurring scheduled update from repository job completed and updates were staged. The system will now restart to apply the staged updates. Detailed Description The recurring scheduled update from repository job completed and updates were staged. The system will now restart to apply the staged updates. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED070 Message Unable to configure the Automatic Backup schedule. Detailed Description Unable to configure the Automatic Backup schedule due to invalid input parameters. Recommended Response Action Verify the input parameters to the set Automatic Backup schedule method are correct and retry the operation.
Category Configuration (RED = FW Download) Severity Severity 2 (Warning) No alerts are applicable for this message RED073 Message The input value entered for the parameter arg1 is invalid. Arguments arg1 = parameter Detailed Description The operation did not complete successfully because of an invalid value for the parameter identified in the message. Recommended Response Action Verify the value for the parameter identified in the message is valid and retry the operation.
RED076 Message Unable to create an Automatic Update schedule, because an invalid parameter is entered. Detailed Description Unable to create the Automatic Update schedule because an input parameter is invalid.. Recommended Response Action Verify the values for all the input parameters are correct and retry the operation.
Arguments arg1 = parameter Detailed Description The operation did not complete successfully because of an invalid value for the parameter identified in the message. Recommended Response Action Verify the value for the parameter identified in the message is valid and retry the operation. Category Updates (RED = FW Download) Severity Severity 2 (Warning) No alerts are applicable for this message RED080 Message The required parameter arg1 is not present.
Recommended Response Action Enable the correct job schedule type, and then retry the operation. For example, to enable the Automatic Update feature, select the Enable Automatic Update option. Category Updates (RED = FW Download) Severity Severity 2 (Warning) No alerts are applicable for this message RED083 Message The Chassis firmware is not updated because the version currently on the Chassis is same as the requested version.
RED085 Message Unable to update the Chassis firmware, communication with Chassis Management Controller took more time than expected. Detailed Description The Chassis firmware cannot be updated because communication between iDRAC and CMC took more time than expected. Recommended Response Action Verify the status of CMC by accessing the CMC and making sure it is functioning and responding and then retry the operation. For more information about troubleshooting a CMC issue, see the CMC User Manual.
select iDRAC > Update, click on the Settings tab, select Enabled for the setting and then click Apply button. Category Updates (RED = FW Download) Severity Severity 2 (Warning) No alerts are applicable for this message RED088 Message Unable to update the Chassis firmware because an update operation is already in progress. Detailed Description The Chassis firmware cannot be updated because an update operation is already in progress.
RED090 Message A Chassis firmware update operation is no longer in progress. Detailed Description A Chassis firmware update operation is no longer in progress. This is not an indication of success or failure. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED093 Message The requested job cannot be scheduled because Lifecycle Controller is not enabled.
Arguments arg1 = component name, arg2 = available firmware version, arg3 = installed firmware version Detailed Description The firmware for the component identified in the message is being updated to the firmware version identified in the message. Recommended Response Action No response action is required.
RED096 Message The maximum iDRAC storage space allocated for storing firmware image files is reached. The firmware image of the earlier version that was stored for a rollback operation is now deleted. Detailed Description The maximum iDRAC storage space allocated for storing firmware image files is reached. The firmware image of the earlier version that was stored for a rollback operation is now deleted. Recommended Response Action No response action is required.
RED098 Message Unable to complete the firmware update operation because the specified firmware image is not compatible with the target system model. Detailed Description Unable to complete the firmware update operation because the specified firmware image is not compatible with the target system. Recommended Response Action Identify and download the firmware version that corresponds to the system model being updated, and retry the operation.
49 RFL Event Messages RFL2000 Message Internal Dual SD Module arg1 is present. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
OMSA Event ID iDRAC 5303 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC RFL2003 Message Internal Dual SD Module arg1 is online. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Reinstall the SD module and remove and reinstall SD cards. Category System Health (RFL = IDSDM Media) Severity Severity 1 (Critical) Trap/EventID 2209 LCD Message Internal Dual SD Module failed.
RFL2006 Message Internal Dual SD Module arg1 is write protected. Arguments arg1 = name Detailed Description The module is write-protected. Changes may not be written to the media. Recommended Response Action if unintended, remove the media and disable write protection. Category System Health (RFL = IDSDM Media) Severity Severity 2 (Warning) Trap/EventID 2210 LCD Message Internal Dual SD Module is write protected.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RFL2008 Message Internal Dual SD Module arg1 is disabled. Arguments arg1 = name Detailed Description The Internal Dual SD Card redundancy feature was disabled. The SD card identified in the message is disabled. Recommended Response Action No response action is required.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC CMC 1480 ✔* ✔ Reset Chassis Event Proxy
50 RFLA Event Messages RFLA2001 Message Internal Dual SD Module arg1 is absent. Arguments arg1 = name Detailed Description The SD card module is not detected or not installed. Recommended Response Action If unintended, reinstall the SD module. Category System Health (RFLA = IDSDM Absent) Severity Severity 1 (Critical) Trap/EventID 2481 LCD Message Internal Dual SD Module is absent. Check SD card.
51 RFM Event Messages RFM1018 Message Removable Flash Media is absent. Detailed Description None Recommended Response Action No response action is required. Category System Health (RFM = FlexAddress SD) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RFM1019 Message Removable Flash Media is present.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1020 Message Removable Flash Media is IPMI-function ready. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1022 Message Removable Flash Media is ready. Detailed Description None Recommended Response Action If unintended, reinstall the flash media.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1024 Message Removable Flash Media is offline. Detailed Description At boot, the Card Identification (CID) signature of the card is different from the Non-volatile (NV) storage value or the card is the destination of a copy operation that is in-progress. Recommended Response Action If unintended, reinstall the flash media.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1026 Message Failure detected on Removable Flash Media. Detailed Description An error is reported during a SD card read or write. Recommended Response Action Re-install the flash media, if the issue persists replace the media.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1028 Message Removable Flash Media was activated. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1030 Message Removable Flash Media is booting. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1032 Message Removable Flash Media is write protected. Detailed Description The card is write-protected by the physical latch on the SD card. IDSDM cannot use a write-protected card. Recommended Response Action if unintended, remove the media and disable write protection.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1034 Message Media not present for Removable Flash Media. Detailed Description The SD card is not detected or not installed. Recommended Response Action If unintended, reinstall the flash media.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC 1491
52 RRDU Event Messages RRDU0001 Message Internal Dual SD Module is redundant. Detailed Description None Recommended Response Action No response action is required.
LCD Message Internal Dual SD Module redundancy lost. Check SD cards OMSA Event ID 5306 OMSA Trap ID 5306 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC RRDU0003 Message Internal Dual SD Module redundancy is degraded. Detailed Description Either one of the SD card or both the SD cards are not functioning properly.
Detailed Description None Recommended Response Action Install additional SD card and configure for redundancy if redundancy is desired.
RRDU0006 Message Internal Dual SD Module rebuild initiated. Detailed Description Internal Dual SD Module rebuild initiated. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RRDU0008 Message Internal Dual SD Module rebuild did not complete successfully. Detailed Description Internal Dual SD Module rebuild failed because read/write to one of the SD cards failed. Recommended Response Action Replace the failed SD card and retry rebuild.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RRDU0011 Message Unable to determine the redundancy status of the Internal SD Module. Detailed Description This occurs because of one of the following reasons: 1) Either one of the SD card or both the SD cards have failed. 2) The Internal SD Module has failed.
RSI Event Messages RSI0001 Message The Lifecycle Controller Remote Services is available. Detailed Description The Lifecycle Controller Remote Services instrumentation is available. Recommended Response Action No response action is required.
RSI0004 Message The remote service is unavailable Detailed Description The Remote Service database is unavailable. Recommended Response Action Reset Integrated Remote Access Controller (iDRAC).
54 SEC Event Messages SEC0000 Message The chassis is open. Detailed Description The chassis is open. System performance may be degraded, and security may be compromised. Recommended Response Action Close the chassis. Check system logs. Category System Health (SEC = Security Event) Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message Intrusion detected.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0002 Message The I/O card area is open. Detailed Description The I/O card area is open. I/O cards may be added or removed. System performance may be degraded. Recommended Response Action Close the I/O card area. Check system logs.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0004 Message The LAN is disconnected. Detailed Description The LAN is disconnected. Network performance may be degraded. Recommended Response Action If unintentional, connect network cable.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0006 Message The fan area is open. Detailed Description The fan area is open. System performance may be degraded. Recommended Response Action Close the fan area. Check system logs.
OMSA Event ID 5252 OMSA Trap ID 5252 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEC0017 Message The drive bay is closed. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0019 Message The processor area is closed. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0021 Message The docking is authorized. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0031 Message The chassis is open while the power is on. Detailed Description The chassis is open. System performance may be degraded, and security may be compromised. Recommended Response Action Close the chassis. Check system logs.
Severity Severity 3 (Informational) Trap/EventID 2387 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEC0033 Message The chassis is open while the power is off. Detailed Description The chassis is open while the power is off. System security may have been comprised.
Recommended Response Action No response action is required. Category System Health (SEC = Security Event) Severity Severity 3 (Informational) Trap/EventID 2387 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEC0040 Message A critical stop occurred during OS load.
Detailed Description TXT initialization cannot be completed because system configuration may have changed. Recommended Response Action Check system hardware inventory for TPM presence, clear and reconfigure TPM and TXT in BIOS setup menu. Category System Health (SEC = Security Event) Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message Unable to configure TXT. Reconfigure TPM and TXT in BIOS.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SEC0043 Message BIOS Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) problem during POST. Detailed Description TXT POST cannot be completed because system configuration may have changed. Recommended Response Action Check system hardware inventory for TPM presence, clear and reconfigure TPM and TXT in BIOS setup menu.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC SEC0045 Message Intel Trusted Execution Technology (TXT) is operating correctly. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 2 (Warning) OMSA Event ID 5251 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEC0052 Message Chassis intrusion sensor may have failed. Detailed Description The chassis intrusion sensor may have failed, because of this it cannot be determined whether the chassis is closed or opened.
Detailed Description The Storage disk tray identified in the message is open. The tray should be closed as soon as any service action is completed. Leaving the tray open for an extended period may result in drives over heating. Recommended Response Action Close the Storage disk tray identified in the message.
SEC0102 Message The arg1 in slot arg2 is closed. Arguments arg1 = module name, arg2 = slot number Detailed Description The module or Storage tray identified in the message is closed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEC0601 Message A secure mode violation was corrected. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEC0603 Message User password violation was corrected. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEC0605 Message A setup password violation was corrected. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEC0607 Message The network boot password violation was corrected. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEC0609 Message A password violation was corrected. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEC0611 Message An Out-of-band password violation was corrected. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC ✔ ✔ ✔ CMC ✔ ✔* ✔* OS Log Power Off LC Log iDRAC ✔* CMC ✔* LCD Remote System Log WS Eventing ✔ Power Cycle Reset Chassis Event Proxy ✔ ✔* SEC0613 Message The default username and password is changed. Detailed Description The default username and password is changed. Recommended Response Action No response action is required.
Category Configuration (SEC = Security Event) Severity Severity 2 (Warning) Trap/EventID 10578 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC SEC0701 Message Warning: Default username and password are currently in use. It is strongly recommended to change the default password immediately.
55 SEL Event Messages SEL0002 Message Logging is disabled. Detailed Description This message appears when event logging of a specific type is disabled by the user. (IPMI sensor type code 10h - offset 01h) Recommended Response Action If unintended, re-enable logging.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL0004 Message Log cleared. Detailed Description None Recommended Response Action No response action is required.
Trap/EventID Filter Visibility 2377 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL0007 Message All event logging is enabled. Detailed Description None Recommended Response Action No response action is required.
Category System Health (SEL = Sys Event Log) Severity Severity 1 (Critical) Trap/EventID 2377 LCD Message SEL is full. Review & clear log Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* SEL0010 Message System event log (SEL) is almost full.
Detailed Description if the system event log failed to initialize platform status and failure events are not captured. Some management software will not report platform exceptions. Recommended Response Action Reboot the management controller or iDRAC. Cycle system input power. If problem persists call support.
SEL0014 Message The System Event Log (SEL) was cleared by arg1 from arg2 . Arguments arg1 = username, arg2 = IP address Detailed Description The System Event Log (SEL) was cleared by the username identified in the message from the IP address identified in the message. Recommended Response Action No response action is required.
SEL1202 Message OEM system boot. Detailed Description None Recommended Response Action No response action is required. Category System Health (SEL = Sys Event Log) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEL1204 Message An unknown system hardware failure detected.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SEL1205 Message The unknown system hardware failure was corrected. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1207 Message An entry was removed from auxiliary log. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1209 Message The platform event filter action failed. Detailed Description System policies or permissions may prevent the action from executing. If configured, the system will not execute the action on a platform event (power down, cycle, interrupt, send alert). Recommended Response Action Review platform event configuration.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1211 Message The time-stamp clock could not be synchronized. Detailed Description The time stamp on system event log events may not correlate to the system time. (IPMI sensor type code 12h - offset 05h) Recommended Response Action Cycle system input power, if problem persists call support.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1301 Message Bootable media found. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1303 Message Bootable diskette detected. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1305 Message The PXE server found. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1307 Message Boot sector found. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1309 Message User selected a boot source. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1402 Message The platform generated a LAN alert. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1406 Message The platform generated a SNMP trap. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* SEL1501 Message Chassis management controller (CMC) redundancy is lost. Detailed Description An action or failure has taken place that breaks CMC redundancy. This includes loss of network connection, hardware failures, firmware update, firmware mismatch between CMCs, CMC reset, and unplugging a CMC. Recommended Response Action Check CMC network cables and network connections.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL1503 Message The chassis management controller (CMC) is not redundant. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2377 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL1506 Message Lost communications with Chassis Group Member arg1 . Arguments arg1 = number Detailed Description The primary CMC has lost communication with the indicated member CMC.
Detailed Description None Recommended Response Action No response action is required. Category System Health (SEL = Sys Event Log) Severity Severity 3 (Informational) Trap/EventID 2379 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL1508 Message Member arg1 could not join the Chassis Group.
SEL1509 Message Member arg1 has joined the Chassis Group. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* SEL1511 Message Member arg1 removed from the Chassis Group. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEL9901 Message OEM software event. Detailed Description The current software version cannot decode this event. The source of the event may come from a source that is not compatible with this software or the event may have been added after the release of this software.
Category System Health (SEL = Sys Event Log) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC 1549
56 SSD Event Messages SSD1001 Message Write-cache on arg1 is enabled. Arguments arg1 = PCIe SSD name Detailed Description Write-cache is enabled on the PCIe solid state drive (SSD) identified in the message. Recommended Response Action No response action is required.
OMSA Event ID 2428 OMSA Trap ID 90300 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SSD1003 Message arg1 is ready for removal. Arguments arg1 = PCIe SSD name Detailed Description The PCIe solid state drive (SSD) identified in the message is ready for removal. Recommended Response Action No response action is required.
Detailed Description The log file of the PCIe solid state drive (SSD) identified in the message is successfully exported. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SSD1006 Message The arg1 has reached arg2 of warranted device wear-out limit. Arguments arg1 = PCIe solid state device name, arg2 = percent Detailed Description The PCIe solid state device identified in the message is approaching the warranted wear-out limit. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 90300 IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SSD1008 Message The arg1 is approaching read-only mode. Arguments arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode. Recommended Response Action No response action is required.
Detailed Description The PCIe solid state device identified in the message is in read-only mode. Recommended Response Action Back up the data on the device, and contact your service provider for further instructions.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SSD1011 Message The Remaining Rated Write Endurance Threshold for PCIe SSDs is set to arg1 . Arguments arg1 = value Detailed Description The Remaining Rated Write Endurance (RRWE) Threshold for PCIe solid state devices has been modified. A warning alert is generated when the RRWE for any PCIeSSD device falls below the user set RRWE Threshold value. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) OMSA Event ID 2448 OMSA Trap ID 10100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC 1557
STOR Event Messages STOR001 Message The command is successfully run. Detailed Description The command is successfully run. Recommended Response Action No response action is required. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR003 Message Missing parameter. Detailed Description Required parameter is missing. Recommended Response Action Refer to the RAID profile to determine required parameters.
STOR006 Message Unable to complete the operation. Detailed Description The operation could not be completed because of an issue with the management controller (either the iDRAC or the Chassis Management Controller (CMC)) that is managing the storage. Recommended Response Action Retry the operation. If the issue persists, contact your service provider.
Detailed Description The operation cannot be completed because the RAID level entered is not supported by the controller. Recommended Response Action Enter a valid RAID level and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR0101 Message No RAID controller is displayed. Detailed Description No RAID controller data to display.
Category Storage (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR0104 Message No virtual disks are displayed. Detailed Description No virtual disk data to display. The system is powered off, physical disks are not present on the system, or virtual disks are not created. Recommended Response Action Check if the server has power, physical disks are available, and virtual disks are created.
STOR0107 Message EMMs are not connected to enclosures or data about EMMs is unavailable. Detailed Description No EMMs data to display. The system is powered off, no enclosure EMMs are present, or the EMMs are not connected to the enclosures. Recommended Response Action Check if the server has power, EMMs are available, and EMMs are connected to the enclosure.
STOR011 Message Stripe size not supported on controller. Detailed Description The operation cannot be completed because the stripe size entered is not supported by the controller. Recommended Response Action Enter a valid stripe size and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR0110 Message Invalid Fully Qualified Device Descriptor (FQDD).
Detailed Description One or more of the specified physical disks cannot be used for the operation requested. Physical disk protocol and media type, along with other physical disk characteristics like Secure Encryption and T10 protection, need to match the requirements of the requested operation. Recommended Response Action Make sure the specified physical disk has the appropriate protocol and media type for the requested operation.
Recommended Response Action Specify a physical disk with a larger capacity or replace the specified physical disk with one with more capacity, and then retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR017 Message The specified Virtual Disk is not valid for the operation.
Severity Severity 2 (Warning) No alerts are applicable for this message STOR020 Message A controller key is already present. Detailed Description The controller key cannot be set because a key is already present. Recommended Response Action Delete the current key and retry the operation. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR0200 Message Array Manager is installed on the system.
STOR0201 Message Unable to determine whether the system has the minimum required versions of the RAID controller drivers and firmware. Detailed Description Unable to determine whether the system has the minimum required versions of the RAID controller drivers. Recommended Response Action See the Readme file on the installation media for driver and firmware requirements.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR0203 Message The current operating system kernel version and the non-RAID SCSI driver version are older than the minimum required versions. Detailed Description The version of the operating system kernel and the driver do not meet the minimum requirements.
Recommended Response Action See the Readme file for the driver requirements and update the system to meet the minimum requirements and reinstall Storage Services.
STOR0206 Message Smart thermal shutdown feature is enabled. Detailed Description The storage shutdown feature based on high ambient temperature (smart thermal shutdown) is enabled. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR0208 Message Protection policy has changed. Detailed Description A new protection policy is created or an existing protection policy is modified. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 10400 IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR021 Message The controller key is not present. Detailed Description The virtual disk cannot be secured because a controller key is not present. Recommended Response Action Set an appropriate controller key and retry the operation.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR0211 Message The arg1 has returned to normal state. Arguments arg1 = device name Detailed Description The device identified in the message that was previously in an error state has returned to a normal state. For example, if an enclosure became too hot and subsequently cooled down, or if a degraded virtual disk returns to normal state. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) OMSA Event ID 2048 OMSA Trap ID 75400;80400;85400;90400;95400;100400;105400;110400;115400;120400 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR022 Message The controller is not security capable. Detailed Description The specified controller does not have the capability to secure virtual disks.
STOR024 Message Unable to create a configuration job because a configuration job for the device already exists. Detailed Description Configuration changes for the specified device are already scheduled. Recommended Response Action No response action is required. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR025 Message Unable to delete any pending configuration because the configuration job is already scheduled.
STOR027 Message Virtual Disk name is not supported. Detailed Description Setting the Virtual disk name is not a valid operation on the specified controller. Recommended Response Action Do not specify the virtual disk name and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR028 Message Virtual disk not found.
Detailed Description The requested operation cannot be completed because the specified controller is not found. Recommended Response Action Provide a valid controller FQDD (Fully Qualified Device Descriptor) and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR031 Message Lifecycle Controller is not enabled.
STOR033 Message Invalid parameter value for Start/Until Time. Detailed Description The requested operation cannot be completed because an invalid value is specified for Start/Until Time. Recommended Response Action Enter a valid Start/Until Time and retry the operation. For more information about the Start/Until Time, see the RAID Profile specification.
STOR037 Message Missing required parameter arg1 . Arguments arg1 = parameter name Detailed Description Unable to complete the requested operation because one or more input parameters identified in the message are not specified. Recommended Response Action Enter all the required parameters and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR038 Message Invalid parameter value for arg1 .
STOR040 Message Invalid AttributeName arg1 . Arguments arg1 = attribute name Detailed Description Unable to complete the requested operation because an invalid AttributeName value is specified. Recommended Response Action Specify a valid AttributeName value for the attribute identified in the message and retry the operation.
STOR043 Message One or more selected physical disk drives are part of virtual disk that is not Secondary RAID Level 0. Detailed Description One or more physical disk drives selected for the operation are part of a virtual disk that is not Secondary RAID Level 0. Recommended Response Action This operation is not supported unless the previous virtual disk on the selected physical disk drives are deleted first.
STOR046 Message The specified StartingLBA and Size values combination result in an overlapping virtual disk. Detailed Description Unable to complete the create virtual disk operation because the StartingLBA and Size value combination results in an overlapping virtual disk. Recommended Response Action Refer to the users guide to provide the correct StartingLBA and Size combination values.
STOR049 Message Controller is in Local Key Management mode. Detailed Description The controller is in Local Key Management mode. Recommended Response Action No response action is required. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR050 Message Controller is in Dell Key Management mode. Detailed Description The controller is in Local Key Management mode. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR0502 Message Unable to launch RAID Configuration wizard. Detailed Description No RAID controller is installed on the system. Recommended Response Action Install the RAID controller and do the following: 1) Reboot the system. 2) Press the key to re-enter Lifecycle Controller. 3) Retry RAID configuration.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR0504 Message Successfully completed RAID operation. Detailed Description The RAID operation was successful. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR0506 Message Unable to create virtual disk. Detailed Description The physical disk is unreadable or the RAID controller is not responding. Recommended Response Action Exit Lifecycle Controller, press the key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, replace the physical disk or update the RAID controller firmware to the latest version, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR0508 Message No supported controllers present for RAID configuration. Detailed Description Unable to configure RAID as the supported RAID controller is not present. Recommended Response Action Install a supported RAID controller and the required number of physical disks for the RAID configuration, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR051 Message StartingLBA and Size value combination is greater than allowed by the physical disk size. Detailed Description The requested operation cannot be completed because the specified StartingLBA and Size value combination is greater than allowed by the physical disk size.
Detailed Description Unable to change the encryption key due to an internal error. Recommended Response Action Exit Lifecycle Controller, press the key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
STOR0513 Message Unable to encrypt virtual disks. Detailed Description Unable to encrypt unsecure virtual disks due to an internal error. Recommended Response Action Exit Lifecycle Controller, press the key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR052 Message Unable to create virtual disk, maximum number of created virtual disks per controller or diskgroup has been reached. Detailed Description Virtual disks cannot be created because the maximum number of logical drives per controller or diskgroup is reached.
STOR055 Message BIOS does not support Dell Key Manager capabilities. Detailed Description The BIOS on the server is not Dell Key Management capable. Recommended Response Action For more information about key management capabilities, see Dell Key Manager or Lifecycle Controller Remote Services Guide available at dell.com/support/manuals.
STOR058 Message This operation is not supported on this device. Detailed Description The operation is not supported on the target device. Recommended Response Action For more information, see Lifecycle Controller-Remote Services documentation. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR059 Message The requested operation is not currently valid because there are no virtual disks on the controller.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR061 Message Initializing virtual disk is not supported on the RAID controller. Detailed Description The initializing virtual disk operation is not supported on the target device. Recommended Response Action For more information about supported operations, see the documentation specific for the targeted RAID controller or the Lifecycle Controller Remote Services Quick Start Guide.
STOR063 Message Unable to assign the specified virtual disk to multiple Virtual Adapters in single assignment mode. Detailed Description In order to prevent data loss, the system has prevented the assignment of a Virtual Disk to multiple Virtual Adapters because the clustered assignment mode is not enabled. Recommended Response Action Enable clustered assignment mode or unassign the virtual disk from the Virtual Adapter it is currently assigned to and retry the operation.
STOR066 Message Controller is not T10 Protection Information capable. Detailed Description The requested operation did not succeed because the selected RAID controller is not T10 Protection Information capable. Recommended Response Action Verify that the RAID controller selected for the operation is T10 Protection Information capable, and then retry the operation.
STOR069 Message Unable to run the arg1 method, because the number of elements entered for VDPropNameArry and VDPropValueArray is unequal. Arguments arg1 = method name Detailed Description The method name identified in the message could not be successfully completed, because the number of elements entered for VDPropNameArry and VDPropValueArray is not equal. Recommended Response Action Enter equal number of elements (pair value), and then retry the operation.
Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR0702 Message The value entered for the arg1 option is invalid Arguments arg1 = option name Detailed Description The value entered for the option name identified in the message is invalid. Recommended Response Action For more information, run the RACADM command "racadm raid help createvd".
STOR072 Message iDRAC Service Module (ISM) is either not present or not running on the server OS. Detailed Description The configuration operation could not be performed because it requires iDRAC Service Module (ISM) service to be present and running in the server Operating System. Recommended Response Action Make sure the iDRAC Service Module (ISM) service is running on the server Operating System and then retry the operation. Refer to the iDRAC User Guide for installing and starting ISM.
STOR075 Message The operation cannot be performed because the enclosure configuration mode (Split or Unified) change request is pending. Detailed Description The requested operation could not be completed because there is an operation pending to change the enclosure configuration mode (Split or Unified). This operation is exclusive because it involves changing the RAID backplane topology.
STOR078 Message The requested operation requires a reboot type that does not match the reboot type required for pending operations. Detailed Description The requested operation cannot be performed because it involves server reboot type which is different than the reboot type of pending operations. Combining operations with different reboot types for the same RAID controller is not supported by iDRAC.
STOR082 Message The operation cannot be stopped or cancelled because the operation is not currently running. Detailed Description The operation cannot be stopped or canceled because the operation is not currently running. Recommended Response Action Make sure the operation is running before attempting to cancel or stop the operation.
STOR089 Message The storage configuration operation is successfully completed and the change is in pending state. Detailed Description The storage configuration operation is successfully completed and the change is in pending state. Recommended Response Action To apply the configuration operation immediately, create a configuration job using the --realtime option. To create the necessary real-time job, run the jobqueue command.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR092 Message Unable to run the configuration operation on the controller because foreign configuration import operation is in progress. Detailed Description The requested configuration operation cannot be run because a foreign configuration import operation on the controller is already in progress. Recommended Response Action Wait for the import process to complete before running any configuration operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR094 Message The storage configuration operation is successfully completed and the change is in pending state. Detailed Description The storage configuration operation is successfully completed and the change is in pending state.
Category Storage (STOR = Storage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR096 Message Unable to create a virtual disk because the disk space size value entered for the virtual disk is less than the lower limit value (100 MB).
Recommended Response Action Enter the FQDD of a physical disk drive that has a larger disk space, and then retry the operation. To view a list of physical disk drives and associated disk space, run the RACADM command "racadm storage get pdisks -o -p size". To view a list of virtual disks and associated size, run the RACADM command "racadm storage get vdisks -o -p size".
STOR1 Message A device arg1 is in an unknown state. Arguments arg1 = device name Detailed Description The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable, or a missing device, or a problem with the driver or firmware. Recommended Response Action See the storage hardware documentation for information on checking the cables. Check for problems with any enclosures attached to the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔* CMC ✔ ✔ ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* STOR11 Message The currently detected hardware configuration is High Availability Ready. However, the current software solution does not yet support high availability. Detailed Description The current hardware configuration is setup correctly for High Availability.
Category Storage (STOR = Storage) Severity Severity 3 (Informational) Trap/EventID 4179 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔* CMC ✔ ✔ ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* STOR13 Message Unable to set the operation mode of the newly inserted storage sled in slot arg1 to Split Single or Split Dural Host, because the storage sled has only one PERC controller.
STOR14 Message The peripheral sled in slot arg1 initialization is not complete. Arguments arg1 = slot number Detailed Description Peripheral sled initialization is not successful with following possible reasons: 1) FRU is not functioning. 2) Sled internal components are not responding. 3) Component power state is not good. 4) Hardware configuration errors.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* STOR16 Message The storage sled arg1 configuration is normal. Arguments arg1 = slot number Detailed Description The configuration of the storage sled in the slot identified in the message is normal. Recommended Response Action No response action is required.
Recommended Response Action Change the slot location of one of the RAID Controllers. Category Storage (STOR = Storage) Severity Severity 2 (Warning) Trap/EventID 4178 Filter Visibility iDRAC ✔ CMC ✔ IPMI Alert LC Log LCD ✔ ✔* SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR18 Message A Shared Storage device is detected in slots other than Chassis Slots 5 and 6.
Arguments arg1 = args Detailed Description A SCSI device experienced an error, but may have recovered. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* STOR300 Message Unable to change the controller mode because there are already pending operations. Detailed Description The requested operation could not be completed because at least one other pending operation was found on the RAID controller. This operation needs exclusivity because it requires a server reboot for changes to apply.
Recommended Response Action Choose a different Apply Operation mode "Apply at Next Reboot" from the Apply Operation Mode drop-down menu. Category Configuration (STOR = Storage) Severity Severity 1 (Critical) No alerts are applicable for this message STOR303 Message Unable to change controller mode while foreign configuration is present on the controller. Detailed Description Controller mode cannot be changed as the controller has foreign configuration associated with it.
Severity Severity 2 (Warning) No alerts are applicable for this message STOR306 Message Unable to change controller mode while security key is assigned to the controller. Detailed Description Controller mode cannot be changed as the controller currently has the security key assigned. Recommended Response Action Delete the security key and retry the operation.
STOR310 Message Unable to initialize the virtual disk because the RAID controller selected does not support the initialization mode. Detailed Description The virtual disk cannot be initialized because the RAID controller selected does not support the initialization mode. Recommended Response Action Make sure that the RAID controller selected for the operation supports the initialization mode, and they retry the operation.
Arguments arg1 = VD/Enclosure Name Detailed Description A virtual disk or enclosure has lost data redundancy. In the case of a virtual disk, one or more physical disks included in the virtual disk have failed. Due to the failed physical disk or disks, the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an additional physical disk will result in lost data. In the case of an enclosure, more than one enclosure component has failed.
Trap/EventID Filter Visibility 4179 IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* STOR7 Message The storage management instrumentation is performing an inventory refresh operation. Detailed Description The storage monitoring instrumentation detected a burst of events from underlying storage controllers.
Recommended Response Action Remove one RAID controller. Category Storage (STOR = Storage) Severity Severity 2 (Warning) Trap/EventID 4178 Filter Visibility iDRAC ✔ CMC ✔ IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ LC Log LCD ✔ ✔* ✔ ✔ ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR9 Message No RAID controllers have been detected. Access to shared storage will not be available.
SUP Event Messages 58 SUP001 Message Insufficient parameters provided. Detailed Description Insufficient Parameters provided for the WSMAN command. Recommended Response Action Make sure the parameters are correct and in the right number and format and retry the action. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP002 Message Job creation failure.
SUP005 Message Invalid reboot value. Detailed Description Reboot value specified is not supported. Recommended Response Action Verify the reboot value and retry the action. Current options available are 1)Power Cycle 2) Graceful shutdown without forced shutdown 3) Graceful shutdown with forced shutdown (~10 minutes wait time). Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP006 Message Update package downloading - Delete failed.
Detailed Description Because of the size of the driver pack, the update process removes the older version of the driver pack from the system before installing the newer version. For that reason, the driver pack update cannot be deleted. Recommended Response Action Wait for the Driver Pack update to complete. To revert to the previous version of the update, download and update the firmware to the version desired.
Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP0103 Message TFTP IP address is not reachable. Detailed Description The specified TFTP server is not reachable. Recommended Response Action Check if the TFTP server is alive. Category Updates (SUP = FW Update Job) Severity Severity 1 (Critical) No alerts are applicable for this message SUP0104 Message TFTP Source path too long.
SUP0106 Message Unable to locate firmware image file in specified path. Detailed Description There is no firmware image present at the specified path. Recommended Response Action Check if the firmware image is present at the specified path. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP0107 Message File path too long. Detailed Description The file path provided as a parameter is too long.
Detailed Description The firmware update cannot proceed without the TFTP IP address. Recommended Response Action Specify the TFTP IP address. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP011 Message Invalid Job ID specified. Detailed Description The specified Job ID was not found in the job queue. Recommended Response Action Verify the job ID and retry the action. Retrieve all open jobs by issuing the GetAllJobs command.
Severity Severity 2 (Warning) No alerts are applicable for this message SUP0112 Message The -p option is not currently supported for remote RACADM and the operating system being used. Detailed Description The requested option is not available for remote racadm/operating system. Recommended Response Action No response action is required.
SUP0115 Message A firmware update is currently in progress. Unable to reset the RAC at this time. Detailed Description The rac cannot be reset, while the firmware update is in progress. Recommended Response Action Wait for the firmware update to finish. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0116 Message The RAC configuration has initiated restoration to factory defaults.
SUP0118 Message iDRAC reset failed. Please reset the iDRAC manually to complete the firmware rollback operation. Detailed Description Success message. Recommended Response Action Manually reset the iDRAC. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0119 Message Firmware rollback failed Detailed Description Success message. Recommended Response Action No response action is required.
Arguments arg1 = Extent of completion Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0122 Message Firmware update completed successfully Detailed Description Success message. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0125 Message Current firmware update status is unknown Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0126 Message Firmware update in progress.
SUP0128 Message Ready for firmware update Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0129 Message Resetting the RAC. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0131 Message FTP firmware update has been initiated. This update process may take several minutes to complete. Detailed Description Success message. Recommended Response Action No response action is required.
Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP016 Message Job cannot be scheduled. Detailed Description Only jobs with the job status of Downloading / Downloaded / Pending Reboot can be scheduled. Recommended Response Action In case there is an update job, wait until the job status is Downloaded and then retry the action.
SUP019 Message Lifecycle Controller is not enabled. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle Controller must be enabled to perform the requested operation.
No alerts are applicable for this message SUP022 Message Job store has reached the maximum storage limit. Detailed Description JobStore file has exceeded the size limit. Delete all unneeded JobIDs from the job store. Recommended Response Action New JobId cannot be stored. Manually delete the failed jobs and retry the operation.
Detailed Description Generic message to show that last command was successful. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP026 Message The input value entered for the parameter arg1 is invalid. Arguments arg1 = parameter Detailed Description The value entered for the parameter identified in the message is invalid.
Recommended Response Action Execute InstallFromRepo method, and then retry the operation. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP029 Message Firmware versions on server match catalog, applicable updates are not present in the repository. Detailed Description The catalog in the repository specified in the operation has the same firmware versions as currently present on the server.
the System Update Utility media or from the System Build Update Utility media and retry the operation. For more information, see Lifecycle Controller Users Guide. Category Updates (SUP = FW Update Job) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0502 Message Unable to collect system inventory.
Detailed Description Unable to retrieve the system ID from BIOS. Recommended Response Action Retry the operation. If the problem persists, do one of the following: 1) Reboot the system and retry the operation. 2) Update the BIOS firmware to the latest version and retry the operation. If the problem continues to persist contact the service provider.
SUP0505 Message Corrupt catalog file. Detailed Description The catalog file in the selected repository is corrupt. Recommended Response Action Select a repository with a valid catalog file, and retry the operation.
SUP0507 Message Unable to download the Update Packages from the FTP server. Detailed Description The FTP server setting details are incorrect. Recommended Response Action Enter the correct FTP server settings details, and retry the operation.
SUP0513 Message Unable to access the Update Package. Detailed Description The specified filename path to the Update Package is incorrect. Recommended Response Action Enter the correct file path where the Update Package is located and retry the operation. If the problem persists, reboot the system and retry the operation.
SUP0515 Message Unable to authenticate the Update Package signature. Detailed Description Lifecycle Controller was unable to authenticate the Update Package digital signature. The Update Package will not be applied unless it has a valid digital signature. Recommended Response Action Download the latest Update Package from your service provider and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP0517 Message Unable to update the arg1 firmware to version arg2 . Arguments arg1 = component, arg2 = version Detailed Description The firmware image specified in the operation did not apply successfully. An internal error may have occurred. Recommended Response Action Retry the operation. If the problem persists, download the latest update package from your service provider, and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0519 Message Unable to validate firmware image for arg1 . Arguments arg1 = component Detailed Description The update firmware image operation is unable to process the firmware image provided. The image is invalid or incompatible with the installed component. Recommended Response Action Retry the operation.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0522 Message Unable to update the BIOS firmware because write protection is enabled. Detailed Description Write protection is enabled for the BIOS image and local BIOS update is disabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0526 Message Unable to continue with firmware update. Detailed Description Unable to continue the firmware update because the catalog file or the update package is corrupt. Recommended Response Action Retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0528 Message Unable to generate a firmware comparison table. Detailed Description An internal error occurred in the Lifecycle Controller while generating the firmware comparison report. Recommended Response Action Exit the Platform Update wizard and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0530 Message Incorrect repository path location. Detailed Description The catalog repository path entered is not accessible. Recommended Response Action Retry the operation with the correct catalog repository path.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0532 Message The repository contains corrupt Update Packages. Detailed Description The repository contains corrupt Update Packages. Recommended Response Action Enter another repository location that contains the desired Update Packages and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0534 Message Unable to locate the catalog file. Detailed Description The catalog file cannot be found in the specified location. Recommended Response Action Specify the correct repository location and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0536 Message Successfully updated arg1 . Arguments arg1 = component and version Detailed Description Component firmware update was successful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0538 Message Unable to update arg1 . Arguments arg1 = component and version Detailed Description Unable to update firmware due to one the following: 1) Update Package is not supported. 2) Trusted Platform Module feature is enabled in BIOS settings. Recommended Response Action Retry the operation.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0540 Message Unable to install update packages because of insufficient space in the iDRAC. Detailed Description The update packages cannot be installed because of insufficient space in the iDRAC even after deleing firmware installation files stored in the Rollback feature.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP1901 Message Firmware update initializing. Detailed Description Firmware update initializing. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP1903 Message Firmware update verify image headers. Detailed Description Firmware update verify image headers. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP1905 Message Firmware update programming flash. Detailed Description Firmware update programming flash. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP1907 Message Firmware update failed. Detailed Description Firmware update failed. Recommended Response Action Reacquire the image from the original source and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP1909 Message Firmware update failed image download. Detailed Description Firmware update failed image download. Recommended Response Action Check that the image is available and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP1911 Message Firmware update initialization complete. Detailed Description Firmware update initialization complete. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC 1663
59 SWC Event Messages SW0725 Message iDRAC7 communication failure. Detailed Description iDRAC7 is busy and does not respond to iDRAC7 configuratorIPMI requests. Recommended Response Action Try AC power cycling the server or upgrade the iDRAC firmware. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0001 Message Unable to save the network settings.
SWC0002 Message Unable to set Part Replacement policies. Detailed Description The Part Replacement policy configuration operation encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0004 Message Unable to add a work note to the Lifecycle Log. Detailed Description The operation to add a work note to the Lifecycle Log encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0006 Message Unable to display the As Shipped hardware inventory. Detailed Description The view As Shipped hardware inventory operation encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0008 Message Unable to write the As Shipped hardware inventory to the specified destination. Detailed Description The export As Shipped hardware inventory operation did not complete because the destination: 1) does not have the specified folder, 2) does not have enough free space, or 3) is read-only.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0012 Message Unable to retrieve the front panel security settings. Detailed Description The operation to retrieve the front panel security settings encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0014 Message Unable to set new date and time. Detailed Description Unable to apply the changes to the date and time settings because an internal error occurred. Recommended Response Action Exit the Date and Time wizard and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0016 Message Unable to initialize OS Deployment wizard. Detailed Description The operating system driver pack is missing or not accessible. Recommended Response Action Exit the OS Deployment wizard and retry the operation. If the problem persists, exit Lifecycle Controller and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0018 Message Unable to apply the boot mode settings for BIOS. Detailed Description The BIOS boot mode settings could not be applied due to an internal error. Recommended Response Action Exit the OS Deployment wizard and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0023 Message Successfully configured encryption. Detailed Description Encryption configuration is successful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0025 Message The operation completed successfully, however the system is unable to automatically shut down. Detailed Description The operation completed successfully, however the system is unable to automatically shut down. Recommended Response Action Manually shut down the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0027 Message Successfully backed up a Server Profile by using the Lifecycle Controller GUI. Detailed Description The backup Server Profile operation successfully completed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0029 Message Unable to retrieve status of backup Server Profile operation. Detailed Description Status of backup Server Profile operation could not be retrieved because an unrecoverable error occurred while communicating with iDRAC. Recommended Response Action Reset iDRAC and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0031 Message Unable to initiate the backup Server Profile backup operation. Detailed Description iDRAC is unable to initiate the backup Server Profile operation because an unrecoverable error occurred. Recommended Response Action Reset iDRAC and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0033 Message Successfully exported the Server Configuration Profile image file to network share. Detailed Description Exporting the Server Configuration Profile image file to the network share was successful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0035 Message Unable to initialize backup Server Profile operation. Detailed Description The backup operation did not initialize because the system does not have a service tag. Recommended Response Action Assign a service tag to the system and retry the operation.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0037 Message Unable to export the file to the network share. Detailed Description Lifecycle Controller is unable to export the file to the network share because the destination folder is not present or inaccessible.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0039 Message Unable to find the backup Server Configuration Profile image. Detailed Description The backup Server Configuration Profile image partition is not present in the vFlash SD card.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0041 Message Unable to copy the backup Server Configuration Profile. Detailed Description The specified source file location is incorrect. Recommended Response Action Make sure that the specified source file location is correct and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0043 Message Import Server Profile operation completed with errors. Detailed Description The Import Server Profile operation has completed with errors. For more information, see the Lifecycle Log. Recommended Response Action Exit the Import Server Profile wizard and retry the operation.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0045 Message Unable to complete the Import operation. Detailed Description The Import operation did not successfully complete. For more information, see the Lifecycle Log. Recommended Response Action Exit the Import Server Profile wizard and retry the operation.
Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0047 Message Incorrect backup Server Configuration Profile file passphrase provided. Detailed Description The passphrase specified is not correct. Recommended Response Action Enter the valid passphrase and retry the operation.
Recommended Response Action Do one of the following and retry the operation: 1) Reinsert the vFlash SD card with correct backup image file. 2) Enter the passphrase that was used to secure the backup server configuration profile image file.
Recommended Response Action Retry the Import operation using a valid backup image file and the correct passphrase. If the problem persists, do the following: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Detailed Description An error occurred while retrieving the operating system drivers. Recommended Response Action Exit the OS Deployment wizard and update the system with the latest operating system driver packs available from the service provider and retry the operation. For more information, see the Lifecycle Controller users guide.
Detailed Description There was an internal error while saving the settings. Recommended Response Action Retry the operation. If the problem persists, reboot the system or update the Lifecycle Controller firmware to the latest version and retry the operation.
Detailed Description Unable to export the file to the USB drive because it does not have the specified folder, does not have enough free space, or is read-only. Recommended Response Action Make sure that the USB drive contains the folder specified, has enough free space, or is not read-only. If the problem persists, reboot the system and retry the operation.
SWC0058 Message Unable to complete the operation. Detailed Description An internal processing error occurred. Recommended Response Action Reboot the system and retry the operation. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0059 Message Unable to complete the operation.
SWC0060 Message Unable to complete the operation. Detailed Description One or more vFlash partitions are attached. Recommended Response Action Use iDRAC Web interface to detach the vFlash partitions and retry the operation.
SWC0062 Message Unable to export Lifecycle Log. Detailed Description The destination folder is not present, the destination is full or write-protected. Recommended Response Action Verify the following and retry the operation: 1) Destination folder is present. 2) Destination has enough free space. 3) Destination is not write-protected. If the problem persists, perform an AC power cycle and retry.
SWC0064 Message Unable to mount the network share. Detailed Description The details provided to access the network share are incorrect. Recommended Response Action Enter the correct network share details, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0066 Message Unable to connect to the Network Share. Detailed Description Unable to connect to the Network Share due to one of the following: 1) Login credentials entered are incorrect. 2) Network is inaccessible. 3) System IP address conflicts with another system on the network. Recommended Response Action Verify the login credentials.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0068 Message Unable to retrieve the boot mode settings from BIOS. Detailed Description The BIOS boot mode settings could not be retrieved because of an internal issue. Recommended Response Action Exit the OS Deployment wizard and retry the operation. If the problem persists, exit Lifecycle Controller and perform an AC power cycle.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0070 Message The Tech Support Report is successfully exported to the USB drive. Detailed Description The Tech Support Report is successfully exported to the USB drive. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0072 Message Unable to export the Tech Support Report to destination folder. Detailed Description Tech Support Report cannot be exported to the destination folder. Recommended Response Action Verify the following and retry the operation: 1) Destination folder is present. 2) Destination folder has sufficient free disk space. 3) Destination folder is not writeprotected.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0074 Message Unable to start operation with the current iDRAC version. Detailed Description The export operation of Tech Support Report cannot be started because the current version of iDRAC firmware does not support the operation. Recommended Response Action Update iDRAC firmware to the latest version and retry the operation. If the issue persists, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0076 Message The following iDRAC internal storage partitions present in the system were not mounted during the system startup: arg1 Arguments arg1 = partitions Detailed Description Lifecycle Controller detected that the iDRAC internal storage partitions identified in the message were not made available by BIOS during the boot process. Recommended Response Action No response action required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0101 Message Unable to read available log records. Detailed Description Racadm is unable to read the available log records at this point. Retry the command. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0104 Message The -R option is not valid for the specified log. Detailed Description The specified log does not take in the -r option. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0105 Message Invalid -m option.
SWC0107 Message More than one option is not allowed with this command. Detailed Description The command takes in only one option which is the Session ID. Recommended Response Action Enter the command only with one option i.e. the Session ID Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0108 Message The service tag is not currently populated. Detailed Description The Service Tag string is empty.
Detailed Description The build information is not available for racdump. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0111 Message A server action command must be specified. Detailed Description The serveraction subcommand requires an option to be specified. Recommended Response Action Refer the help for serveraction subcommand, and enter a valid option.
Severity Severity 3 (Informational) No alerts are applicable for this message SWC0114 Message The -o option cannot be used with any other options. Detailed Description The syntax of the setniccfg command is invalid. Recommended Response Action Refer the help text for setniccfg subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0115 Message The -s option cannot be used with any other options.
SWC0117 Message Invalid syntax. Both -f and -t must be specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Refer the help text for sslcertdownload subcommand. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0118 Message Invalid syntax. -f must be specified. Detailed Description The syntax of the sslcertupload command is invalid.
Detailed Description The syntax of the sslcertview command is invalid. Recommended Response Action Refer the help text for sslcertview subcommand. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0121 Message Invalid syntax. User index (-i) must be specified. Detailed Description The syntax of the sslcertview command is invalid. Recommended Response Action Refer the help text for sslcertview subcommand.
Severity Severity 2 (Warning) No alerts are applicable for this message SWC0124 Message The -u option requires -f to be specified. Detailed Description The syntax of the sslcsrgen command is invalid. Recommended Response Action Refer the help text for sslcsrgen subcommand. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0125 Message Unable to generate CSR. Detailed Description The CSR file could not be generated.
SWC0127 Message Unable to open file for writing. Detailed Description The file may be write protected and hence could not be edited. Recommended Response Action Check if the file is write protected. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0128 Message The Common Name (CN) field of the CSR Security group must be configured before a CSR can be generated.
Detailed Description The Trap needs to be set for the particular index for the testtrap to go through. Recommended Response Action Set cfgIpmiPetAlertEnable in cfgIpmiPet group using config subcommand for the corresponding index. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0131 Message Trap destination address must be configured. Detailed Description The destination Ip address must be configured for the Trap.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0134 Message The RAC log was cleared successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0135 Message The SEL was cleared successfully Detailed Description Success message.
SWC0137 Message The coredump was deleted successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0138 Message Coredump request completed successfully Detailed Description Success message. Recommended Response Action No response action is required.
SWC0140 Message RAC reset operation initiated successfully. It may take up to a minute for the RAC to come back online again. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0141 Message Certificate successfully downloaded from the RAC Detailed Description Success message.
Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0144 Message Certificate successfully uploaded to the RAC. The RAC will now reset to enable the new certificate and may be offline temporarily. Detailed Description Success message. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0147 Message ASR request completed successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0148 Message Test email sent successfully Detailed Description Success message.
SWC0150 Message Object value is valid Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0151 Message RAC configuration saved to file successfully Detailed Description Success message. Recommended Response Action No response action is required.
Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0154 Message Generating CSR. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) No alerts are applicable for this message SWC0157 Message User certificate successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0158 Message User CA certificate successfully uploaded to the RAC. Detailed Description Success message.
SWC0160 Message PK SSH Authentication Key file successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0161 Message PK SSH Authentication operation completed successfully. Detailed Description Success message. Recommended Response Action No response action is required.
Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0203 Message Key file successfully uploaded Detailed Description Help Text. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) No alerts are applicable for this message SWC0206 Message View user certificate information Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0207 Message Display the version info of RACADM Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0209 Message Connect or disconnect image server connections Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0210 Message Display NIC teaming information Detailed Description Help Text. Recommended Response Action No response action is required.
Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0213 Message Disable the Virtual Console from a local Console Detailed Description Help Text. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0216 Message The -c option requires -l to also be specified. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command.
SWC0219 Message The -p option requires -c to also be specified. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0220 Message The -u option requires -c to also be specified. Detailed Description The syntax of the command is incorrect.
Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0223 Message Invalid syntax. The -d option is not valid with -p. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command.
Severity Severity 3 (Informational) No alerts are applicable for this message SWC0226 Message No valid directory service certificate exists Detailed Description The Remote/Firmware racadm did not find any AD/LDAP certificate at specified path. Recommended Response Action No response action is required.
SWC0229 Message Some Necessary tag(s) are missing: -i -o -e -t -f & -s must be specified for create partition. Detailed Description Insufficient arguments passed to the command. Recommended Response Action Refer the help text for vflashpartition command. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0230 Message vFlash not enabled. Detailed Description vFlash is not enabled.
Detailed Description Remote RACADM commands are not supported on the current iDRAC. Recommended Response Action If remote RACADM is a necessity, upgrade the iDRAC version. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0233 Message No indexes are available to configure additional groups. Detailed Description Indexed groups in the configuration file is more than the indexed groups in iDRAC.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0236 Message Key successfully deleted. Detailed Description The specified public key was deleted from iDRAC. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0237 Message Key text appears to be corrupted.
SWC0239 Message The requested object is not allowed to be configured if IPv6 AutoConfig is enabled. Detailed Description The requested object is auto-assigned if IPv6 AutoConfig is enabled, and hence cannot be configured. Recommended Response Action Disable IPv6 AutoConfig and re-try the command.
Detailed Description The license is missing or expired. This will result in the loss of functionality that is specific to the features supported by the license. Recommended Response Action Import an appropriate license to iDRAC. If you do not know which license to install, contact your service provider.
Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0246 Message Value specified is invalid: Valid range is arg1 . Arguments arg1 = index Detailed Description The specified value is outside of the valid range. Recommended Response Action Verify that a valid value is specified. See the help text or documentation for valid values.
SWC0249 Message Invalid syntax. The requested subcommand requires -i arg1 to be specified. Arguments arg1 = index Detailed Description The specified parameter needs to be given with its legal value. Recommended Response Action Enter the proper index preceded by -i. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0250 Message Invalid syntax. The specified subcommand does not require any options.
SWC0252 Message No options were specified. The subcommand requires options to be used. Detailed Description Invalid number of arguments were passed to the command. Recommended Response Action Refer the help text for the command, and enter the required parameters. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0253 Message Unable to allocate memory needed to perform operation.
Detailed Description Unable to open the specified file. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0256 Message Unable to read file. Detailed Description Unable to read the specified file. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) No alerts are applicable for this message SWC0259 Message Invalid group specified. Detailed Description The value of specified parameter is invalid. Recommended Response Action Refer the list of groups and enter a valid option. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0260 Message Invalid object specified. Detailed Description The value of specified parameter is invalid.
SWC0262 Message Unable to perform operation. Please make sure RAC controller and appropriate IPMI drivers are installed. Detailed Description The IPMI drivers or the RAC controller may not be installed. Recommended Response Action Check if the required modules are installed. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0263 Message Specified path is too long.
Detailed Description The option requested is not available on the DRAC being used. Recommended Response Action Refer to the help to get the list of commands/options valid for the DRAC. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0266 Message Unable to perform the requested operation. Make sure SD card is inserted. Detailed Description The SD card may not be inserted/inserted properly.
Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0269 Message Unable to clear the RAC log. Possible reason may be that Local Configuration using RACADM is disabled. Detailed Description Local Configuration using RACADM may be disabled. Recommended Response Action Check if the Local Configuration using RACADM is disabled and enable it through GUI.
SWC0272 Message Invalid syntax. The -g option is only valid with -o, -i, and -c. Detailed Description The syntax for the config command is invalid. Recommended Response Action Refer to the help text for the config subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0273 Message Invalid syntax. The -g option requires -o to also be specified. Detailed Description The syntax for the config command is invalid.
Detailed Description The syntax for the config command is invalid. Recommended Response Action Refer to the help text for the config subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0276 Message Invalid syntax. The -p option is only valid with -f. Detailed Description The syntax for the config command is invalid. Recommended Response Action Refer to the help text for the config subcommand.
Severity Severity 3 (Informational) No alerts are applicable for this message SWC0279 Message The specified group is not indexed and does not support -i. Detailed Description The group is not indexed and does not require an index to be specified. Recommended Response Action Enter the command without the index. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0280 Message The indexed group specified requires -i arg1 .
SWC0282 Message The specified object is READ ONLY for this index and cannot be modified. Detailed Description The value being modified is READ only. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0283 Message The specified object value is not valid. Detailed Description The value given for the object is not valid.
Detailed Description The value given for the object is not valid. Recommended Response Action Enter a valid value for the corresponding object. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0286 Message Modifying the user configuration at index 1 is not allowed. Detailed Description Objects in the cfgUserAdmin group corresponding to index 1 cannot be modified. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0289 Message Invalid value in config file. Group: arg1 , Object: arg2 , Value: \" arg3 \", Line [ arg4 } Arguments arg1 = Group Name, arg2 = Object Name, arg3 = Value, arg4 = Line No. Detailed Description The specified object value is invalid. Recommended Response Action Configure the specified object and assign a valid value.
No alerts are applicable for this message SWC0292 Message The specified object at index arg1 does not exist. Arguments arg1 = index number Detailed Description The queried object does not exist at the specified index. Recommended Response Action Check for the objects available at the specified index and re-try.
SWC0295 Message Invalid object name specified. Detailed Description The object name specified is incorrect. Recommended Response Action Refer to the list of objects in the group and choose the correct one. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0296 Message The specified value is not allowed to be configured if the user name \nor password is blank.
SWC0298 Message The specified object value cannot be configured if local configuration is disabled or smart card logon is enabled. If smart card logon is enabled, serial, SSH, telnet and IPMIoverLAN is disabled by force and cannot be enabled. Detailed Description The specified object value cannot be configured if local configuration is disabled or smart card logon is enabled. If smart card logon is enabled, serial, SSH, telnet and IPMIoverLAN is disabled by force and cannot be enabled.
SWC0301 Message The specified IP address is not valid. Detailed Description The IP address provided is not valid. Recommended Response Action Specify a valid IP Address. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0302 Message The -s option is not valid with any other option. Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand.
Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0305 Message The -p option requires -u to also be specified. Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand.
Severity Severity 3 (Informational) No alerts are applicable for this message SWC0308 Message The -d option requires -g to also be specified. Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0309 Message The -p option is not supported with the interface being used.
SWC0311 Message Invalid syntax. The -g option is only valid with -i and -o options. Detailed Description The syntax of the getconfig command is invalid. Recommended Response Action Refer the help text for getconfig subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0312 Message Invalid syntax. The -u option is not valid with any other options.
Detailed Description The syntax of the getconfig command is invalid. Recommended Response Action Refer the help text for getconfig subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0315 Message Failed to get object value. Detailed Description The getconfig subcommand failed to get the object value. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) No alerts are applicable for this message SWC0318 Message The starting record must be greater than zero. Detailed Description The value for -s must be greater than zero. Recommended Response Action Enter a value greater than zero, for the option -s. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0319 Message The -i option is not valid with any other options.
SWC0321 Message Unable to open the log for reading. Detailed Description Could not open the log file for reading. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0322 Message Starting record specified exceeds number of records available. Detailed Description The starting record value has to be lesser than the number of records available.
Detailed Description There are no records to display. This might be a result of the log being cleared. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0325 Message The specified object is WRITE-ONLY and cannot be displayed. Detailed Description The requested property is write-only. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0702 Message Power capping is disabled. Detailed Description Power capping is disabled and sets recommended limits for the system. Recommended Response Action No response action is required.
SWC0723 Message Error occurred while Resetting to defaults. The Reset status is not available. Detailed Description iDRAC is not responding to the current Reset status query. Recommended Response Action Retry after a few minutes. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0724 Message Error occurred while Resetting to defaults due to a timeout.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1905 Message RAC Virtual Console configuration has been changed. Detailed Description RAC Virtual Console configuration has been changed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1910 Message User ID arg1 User Name has been changed. Arguments arg1 = username Detailed Description User ID Name has been changed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC1912 Message User ID arg1 User Access Right has been changed. Arguments arg1 = username Detailed Description User ID Access Right has been changed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC1914 Message Network Time Protocol configuration is disabled. Detailed Description Network Time Protocol configuration is disabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC1916 Message Network Time Protocol server configuration has changed. Detailed Description Network Time Protocol server configuration has changed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔* CMC SWC1918 Message HTTPS redirection is enabled. Detailed Description HTTP to HTTPS redirection is enabled. Any iDRAC connection made over the HTTP port (default port number 80) will be redirected to the secure HTTPS port (default port number 443).
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC1921 Message The Chassis Management at Server Mode is disabled. Detailed Description The Chassis Management at Server Mode is disabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1923 Message Unable to modify the server configuration by using Quick Sync because invalid credentials are entered. Detailed Description The server configuration cannot be modified by using Quick Sync because invalid credentials are entered.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1925 Message The iDRAC Quick Sync access feature is set to the Disabled mode. Detailed Description The iDRAC Quick Sync access feature is set to the Disabled mode. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1927 Message The iDRAC Quick Sync access feature is set to the read-only mode. Detailed Description The iDRAC Quick Sync access feature is set to the read-only mode. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1929 Message The iDRAC Quick Sync inactivity timeout value is set to arg1 . Arguments arg1 = timeout period Detailed Description The iDRAC Quick Sync inactivity timeout value is set to the value identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1931 Message The iDRAC Quick Sync inactivity timeout configuration is disabled. Detailed Description The iDRAC Quick Sync inactivity timeout configuration is disabled. The iDRAC Quick Sync feature will remain available after pressing the activate button. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 2338 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SWC4005 Message A firmware or software incompatibility was corrected between iDRAC in slot arg1 and CMC. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Detailed Description FlexAddress is not implemented in one of the versions of firmware. Please update the firmware. Recommended Response Action Check firmware versions of BIOS and CMC. Update to latest version.
SWC4008 Message A firmware or software incompatibility detected between CMC 1 and CMC 2. Detailed Description FlexAddress is not implemented in one of the versions of firmware. Please update the firmware. Recommended Response Action Check firmware versions. Update CMC 1 and CMC 2 firmware to match.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* SWC4010 Message arg1 arg2 in Server- arg3 requires a version of Chassis Management Controller (CMC) firmware 5.0 or later for using the NParEP (ARI mode) functions.
Detailed Description The system has detected a firmware or software incompatibility between the components identified in the message. A mismatch between component versions may cause the system to not function appropriately. Recommended Response Action Update the firmware or software of the components identified in the message. For information about the identified components, see the product documentation available at the service provider support site.
LC Log LCD OS Log iDRAC ✔ ✔ CMC ✔* ✔ Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC5000 Message arg1 upgrade was successful. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC5002 Message arg1 upgrade was successful but encountered minor errors. Arguments arg1 = name Detailed Description None Recommended Response Action Check system logs for minor errors.
Severity Severity 2 (Warning) No alerts are applicable for this message SWC5004 Message System Controller (SC) has restarted functioning. Detailed Description System Controller (SC) has started functioning again because either a server health issue is resolved or SC has completed a firmware update process. Recommended Response Action No response action required.
SWC8500 Message Unable to generate Profile with [ arg1 ] settings. Arguments arg1 = number of entries Detailed Description Unable to communicate with iDRAC. Recommended Response Action Check if iDRAC is ready and system is running properly. Utilize the RACADM command by running "racadm getversion" to list all the servers and make sure the iDRAC version is displayed. If the iDRAC is listed as Not Ready then wait until it becomes ready. A Virtual Reseat may be required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8502 Message A Profile is successfully generated with [ arg1 ] settings. Arguments arg1 = settings count Detailed Description A Profile is successfully generated with the number of settings identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8504 Message arg1 Profile renamed to arg2 and description edited. Arguments arg1 = profile name, arg2 = new profile name Detailed Description The Profile identified in the message was renamed and the description for the Profile was edited. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8506 Message arg1 Profile deleted. Arguments arg1 = profile name Detailed Description The Profile identified in the message has been deleted. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8508 Message Unable to capture Profile from server in slot arg1 Arguments arg1 = slot number Detailed Description Unable to communicate with iDRAC.
Detailed Description Unable to communicate with iDRAC. Recommended Response Action Check if iDRAC is ready and system is running properly. Utilize the RACADM command by running "racadm getversion" to list all the servers and make sure the iDRAC version is displayed. If the iDRAC is listed as Not Ready then wait until it becomes ready. A Virtual Reseat may be required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8511 Message User arg1 was successfully added Arguments arg1 = user name Detailed Description The user name identified in the message was added successfully. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8513 Message Successfully deleted User arg1 . Arguments arg1 = user name Detailed Description The user name identified in the message was successfully deleted. Recommended Response Action No response action is required.
Category Audit (SWC = Software Config) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8515 Message Successfully modified privileges of User arg1 . Arguments arg1 = user name Detailed Description Successfully modified privileges of User identified in the message.
Recommended Response Action Make sure: 1) The login credentials for the operation have user config administration privilege, 2) The user name given is valid. If the issue persists, restart the CMC and retry the operation.
Detailed Description Unable to modify the password of the User identified in the message. Recommended Response Action Make sure: 1) The login credentials for the operation have user config administration privilege, 2) The user name and password given are valid. If the issue persists, restart the CMC and retry the operation.
SWC8520 Message Unable to modify user name from arg1 to arg2 : arg3 - arg4 Arguments arg1 = original user name, arg2 = new_user name, arg3 = error code, arg4 = error message Detailed Description Unable to modify the user name specified in the message. Recommended Response Action Make sure: 1) The login credentials for the operation have user config administration privilege, 2) The user name given is valid. If the issue persists, restart the CMC and retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8522 Message Chassis Group Leader update of member arg1 configuration successful. Arguments arg1 = member id Detailed Description Successfully completed a configuration sync with the member identified in the message. Recommended Response Action No response action required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8524 Message Unable to add arg1 to Chassis Group because a member already exists with the same addressing information. Arguments arg1 = target Detailed Description A Chassis Group member already exists with the same hostname or IP address information as the target identified in the message.
Category Audit (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8526 Message Unable to delete Chassis Group member arg1 ( arg2 ) Arguments arg1 = member id, arg2 = DNS or IP address of member Detailed Description Unable to delete Chassis Group member identified in the message.
Detailed Description Chassis Management Controller unable to update the IDRAC root user username as root. This can happen if the communication to the iDRAC from CMC is nonfunctional or if the username supplied is not valid. Recommended Response Action Make sure the user name is valid. If communication with iDRAC is not successful, reset the iDRAC. Retry the operation after a few minutes.
SWC8529 Message Chassis Management Controller unable to enable the iDRAC root user. Detailed Description The Chassis Management Controller is unable to enable the iDRAC root user. This can happen if the communication to the iDRAC from CMC is non-functional or iDRAC is rebooting Recommended Response Action If communications with the iDRAC is not functioning, reset the iDRAC and retry the operation after a few minutes. Run the RACADM command "racadm ping server " to check the communications.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8531 Message Chassis Management Controller unable to set iDRAC administrator role for root user account. Detailed Description The Chassis Management Controller is unable to set the administrator role for the iDRAC root user.
first slot. The static IPv4 address of each subsequent iDRAC is calculated as a slot number increment of this IPv4 address. Recommended Response Action Make sure there are enough IPv4 addresses for all the iDRACs and then retry the operation.
Detailed Description All keys saved in the Chassis Management Controller for PK SSH Authentication are deleted. Recommended Response Action No response action is required.
SWC8536 Message Unable to add key for slot arg1 of service account, due to corrupt key. Arguments arg1 = slot number Detailed Description The add key operation did not complete successfully for the slot identified in the message due to the key being invalid or corrupt. Recommended Response Action Retry the operation. If the issue persists, contact your service provider.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8538 Message Unable to delete key for slot arg1 of service account, due to problem saving key file. Arguments arg1 = slot number Detailed Description The Public Key (PK) SSH Authentication key file delete operation did not complete successfully because the Chassis Management Controller is unable to access the configuration database. Recommended Response Action Retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8540 Message The add key operation successfully completed for slot arg1 of service account. Arguments arg1 = slot number Detailed Description The Public Key (PK) SSH Authentication key file is successfully uploaded to the Chassis Management Controller.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8542 Message The Profile arg1 is exported. Arguments arg1 = profile name Detailed Description The Profile identified in the message is exported. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8601 Message Quick Deploy Profile unable to apply profile arg1 to server arg2 Arguments arg1 = profile name, arg2 = server number Detailed Description The source profile is not correct in form or content.
Recommended Response Action Retry the operation. If the issue persists, make sure any other operations have completed and then retry the operation.
SWC8604 Message Quick Deploy Profile: Server arg1 does not support configuration using profiles. Arguments arg1 = server number Detailed Description The target server identified in the message does not support server configuration using profiles. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8606 Message Quick Deploy Profile: Timeout exceeded while waiting for remote services ready on Server arg1 . Arguments arg1 = server number Detailed Description The server identified in the message never reported that remote services were ready.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8608 Message Server Profiles: unable to access server: arg1 for operation [ arg2 ] because of one or more of the following reasons: 1) iDRAC is not ready. 2) Lifecycle Controller of the server is disabled.
SWC8609 Message Server Profiles: unknown response received from server: arg1 for operation [ arg2 ] because of one or more of the following reasons: 1) iDRAC is not ready. 2) Lifecycle Controller of the server is disabled. Arguments arg1 = slot number, arg2 = wsman_operation Detailed Description The CMC was unable to perform the operation described in the message because of one or more of the following reasons: 1) iDRAC is not ready. 2) Lifecycle Controller of the server is disabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8611 Message Profile " arg1 " and Server (Service Tag: arg2 in Slot arg3 ) are not compatible.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8613 Message Unable to fully extract arg1 boot list settings from the profile. Arguments arg1 = boot list name Detailed Description The selected profile does not contain setting information for the boot list identified in the message in a usable format.
Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8615 Message Profile is successfully generated. Detailed Description A profile was successfully generated from a server. Recommended Response Action No response action is required.
Detailed Description The server identified in the message cannot be accessed remotely by iDRAC because of one or more of the following reasons: 1) iDRAC is not ready. 2) Lifecycle Controller for of the server is disabled. Recommended Response Action Make sure that the iDRAC on the server identified in the message is operating properly and that Lifecycle Controller is enabled, and then retry the operation. If the issue persists, perform a virtual reseat of the server and retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8618 Message Server Profiles: request arg1 for server in slot arg2 was unsuccessful. Message ID arg3 . Returned fault: arg4 . Arguments arg1 = wsman method, arg2 = slot number, arg3 = message id, arg4 = wsman fault Detailed Description The request for the WS-Man method identified in the message for server in slot identified slot is unsuccessful.
Recommended Response Action Do the following and retry the operation: 1) Make sure the latest firmware is installed on the network cards and iDRAC on the server identified in the message. 2) Reset the Chassis Management Controller. 3) Reset the server iDRAC. If the issue persists, contact your service provider.
SWC8621 Message The Chassis Management Controller is unable to process inventory data from the server in slot arg1 . Arguments arg1 = slot id Detailed Description The Chassis Management Controller (CMC) is unable to process inventory data from the server slot identified in the message. This can happen if there is no free temporary storage in CMC. Recommended Response Action Restart the Chassis Management Controller (CMC).
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8623 Message Unable to save the I/O Aggregator configuration in arg1 . Arguments arg1 = slot id Detailed Description The current configuration details of IOA in the slot identified in the message could not be saved to its startup configuration.
Recommended Response Action Power-cycle the IOA and retry the operation.
SWU Event Messages 60 SWU001 Message The expander or storage enclosure processor firmware is successfully updated. Detailed Description The expander or storage enclosure processor firmware is successfully updated. Recommended Response Action No response action is required. Category Storage (SWU = Software Change) Severity Severity 3 (Informational) No alerts are applicable for this message SWU002 Message The backplane firmware update did not complete successfully.
Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8501 Message The reinstall/rollback request to Lifecycle Controller on server arg1 was not successful. Arguments arg1 = slot number Detailed Description This message is displayed when: 1.
Detailed Description The specified Lifecycle Controller operation is successfully submitted and the operation will be executed on the basis of scheduling criteria. Recommended Response Action No response action required.
SWU8504 Message Successfully scheduled the arg1 operation on the server arg2 . Arguments arg1 = update/reinstall/rollback, arg2 = slot number Detailed Description The specified Lifecycle Controller operation is successfully submitted and the operation will be executed on the basis of scheduling criteria. Recommended Response Action No response action required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWU8506 Message Completed the Firmware update operation for CMC arg1 . Arguments arg1 = slot number Detailed Description Completed the Firmware update operation for the CMC identified in the message.. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8514 Message Unable to update the IOM infrastructure firmware of slot arg1 . ErrorCode=0x arg2 . Arguments arg1 = slot number, arg2 = error no Detailed Description The IOM infrastructure firmware update operation is not successful.
Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8516 Message Unable to update the iDRAC firmware on the server in slot arg1 . Transfer is not successful. ErrorCode=0x arg2 .
Detailed Description Unable to update the iDRAC firmware. The firmware Image file is not accessible. Recommended Response Action Make sure the iDRAC firmware Image file is available in the given path and retry the operation.
SWU8519 Message The firmware update operation of the iDRAC on the server in slot arg1 is stopped. The Image file is corrupted. Arguments arg1 = slot number Detailed Description The iDRAC firmware update operation was stopped, because the Image file is corrupted. Recommended Response Action Reacquire the Image file from the original source, and then retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWU8521 Message The firmware update operation of the iDRAC on the server in slot arg1 was stopped. The selected Image file is not compatible with the server hardware. Arguments arg1 = slot number Detailed Description The firmware update operation of iDRAC identified in the message was stopped. The selected Image file is not compatible with the server hardware.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8523 Message The firmware update operation of the iDRAC on the server in slot arg1 is successfully completed. Arguments arg1 = slot number Detailed Description The firmware update operation of the iDRAC identified in the message is successful. Recommended Response Action No response action is required.
Recommended Response Action Reacquire the Image file from the source folder, and then retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8525 Message Unable to update the iDRAC firmware on the server in slot arg1 . The firmware update timeout limit is exceeded.
Detailed Description The firmware update operation of iDRAC identified in the message is initiated. Recommended Response Action No response action is required. Category Updates (SWU = Software Change) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8527 Message Successfully completed the iKVM firmware update.
Detailed Description The process of iKVM firmware update is not successful due to a checksum error of the firmware image. Recommended Response Action Reacquire the Image file from the source folder, and then retry the operation.
Detailed Description The process for iKVM firmware update was not successful. Recommended Response Action Reacquire the Image file from the source location, and then retry the operation.
SWU8532 Message Unable to update the LKVM firmware, because an invalid parameter is entered. ErrorCode=0x arg1 . Arguments arg1 = error no Detailed Description The LKVM firmware update operation is not successful, because an invalid parameter is entered. Recommended Response Action Retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWU8534 Message Unable to update the iKVM firmware. Detailed Description The iKVM firmware update operation is not successful. Recommended Response Action Reacquire the Image file from the source location, and then retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWU8536 Message Unable to update the LKVM firmware, because the Image file could not be accessed. ErrorCode=0x arg1 . Arguments arg1 = error no Detailed Description The LKVM firmware update operation was not successful, because the firmware Image file could not be transferred.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8538 Message Unable to update the iKVM firmware. Reason = 0x arg1 . Arguments arg1 = error no Detailed Description The iKVM firmware update operation was not successful. Recommended Response Action Retry the Update operation. If the issue persists, reinsert the iKVM and retry the operation.
Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8541 Message Unable to update the PSU firmware, because the Image file is not accessible. ErrorCode=0x arg1 .
Recommended Response Action Make sure that the CMC firmware Image file is available at the location specified in the operation, and then retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8543 Message Unable to update the Active CMC firmware.
Recommended Response Action Retry the firmware update operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8545 Message Unable to update the Standby CMC firmware. Detailed Description The firmware update operation of the Standby CMC was not successful.
Recommended Response Action Retry the update operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8547 Message Unable to update the Standby CMC firmware. The Image transfer process was not successful.
Recommended Response Action Make sure that the CMC firmware image file is available at the location specified in the operation, and then retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8549 Message Unable to update the firmware of Standby CMC and Active CMC.
Recommended Response Action Reacquire the Image file from the source location, and then retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8551 Message Unable to update the firmware of Active CMC. The checksum process was not successful.
Recommended Response Action Reacquire the Image file from the source location, and then retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8553 Message Unable to update the Active CMC firmware. The Image file was not accessible.
Recommended Response Action No response action is required. Category Updates (SWU = Software Change) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SWU8555 Message Active CMC and Standby CMC firmware updates have been initiated. Detailed Description Active and Standby CMC firmware update process is initiated.
Recommended Response Action Perform a Virtual Reseat operation, and then retry the operation. To virtually reseat a server 1) Using the CMC Web UI, go to Chassis Overview > Troubleshooting > Reset Components, and then select slot for the component identified in the message and apply the Virtual Reseat or 2) Run the following RACADM command at the command line interface: "racadm serveraction -f -m sled- reseat".
No alerts are applicable for this message SWU8559 Message The firmware downgrade operation is unsuccessful. A downgrade to the firmware version uploaded is not supported. Detailed Description The firmware downgrade operation is unsuccessful. A downgrade to the firmware version uploaded is not supported. Recommended Response Action Refer to the platform Owners Manual for more information or contact your service provider.
Detailed Description The firmware version selected for rollback does not support the current chassis hardware configuration. Recommended Response Action Make sure that firmware version selected for rollback is supported for the current hardware configuration, such as I/O modules, PSU modules, and servers. For example, a newer generation PSU may not work with an earlier iDRAC or CMC firmware. For more information, see the platform Owners Manual or CMC or iDRAC Release Notes for details.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* 1849
SYS Event Messages 61 SYS001 Message The operation was successful. Detailed Description The operation requested successfully completed. Recommended Response Action No response action is required. Category Configuration (SYS = System Info) Severity Severity 3 (Informational) No alerts are applicable for this message SYS002 Message Unable to perform the operation due to an unknown error in iDRAC.
No alerts are applicable for this message SYS004 Message Invalid parameter value for arg1 . Arguments arg1 = parameter name Detailed Description The value provided for the specified parameter is invalid. Recommended Response Action Refer to the Lifecycle Controller Remote Services documentation and retry the operation with a valid value for the identified parameter.
SYS007 Message Input out of range for arg1 . Arguments arg1 = attribute name Detailed Description The input value for the attribute being set is not within the acceptable range for the attribute. Recommended Response Action Refer to the Lifecycle Controller-Remote Services documentation for the specific attribute and retry the operation with valid value within the range of the attribute.
SYS010 Message Invalid character in value for attribute: arg1 Arguments arg1 = attribute name Detailed Description The input value for the specified attribute is not valid. Recommended Response Action Refer to Lifecycle Controller-Remote Services documentation and provide valid attribute value for the specified attribute.
SYS013 Message Invalid attribute name: arg1 . Arguments arg1 = attribute name Detailed Description The attribute name provided for the requested operation does not exist on the target system or is invalid. Recommended Response Action For more information, see Lifecycle Controller-Remote Services documentation.
SYS016 Message Job completed with errors Detailed Description All the operations in the Job were attempted, but some did not complete successfully. Recommended Response Action Review the Job content and verify the values are correct. For more information, see Lifecycle Controller Remote Services documentation. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS017 Message Job did not complete successfully.
Detailed Description The input is missing a required dependency necessary for the operation. Recommended Response Action Provide the required dependency and retry. For more information, see Lifecycle Controller Remote Services documentation. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS020 Message Invalid required Attribute value. Detailed Description The value provided for the required attribute is invalid.
Category Configuration (SYS = System Info) Severity Severity 1 (Critical) No alerts are applicable for this message SYS023 Message No configuration changes pending. Detailed Description There are no pending values to change. Recommended Response Action Ensure there are pending values for the attributes that need to be set and retry the operation.
Category Configuration (SYS = System Info) Severity Severity 3 (Informational) No alerts are applicable for this message SYS029 Message Unsupported parameter name arg1 . Arguments arg1 = parameter name Detailed Description The parameter name is not supported. Recommended Response Action Remove the unsupported parameter and retry the operation.
Detailed Description The configuration is being applied to a component. Recommended Response Action No response action is required. Category Configuration (SYS = System Info) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS032 Message Staged component configuration is complete.
Detailed Description The staged component configuration update performed in the UEFI environment on the host system has completed, but there were errors. Recommended Response Action No response action is required.
Arguments arg1 = device name Detailed Description The component configuration operation was completed, however some of the configuration values were not successfully applied. Recommended Response Action Retrieve and view configuration operation results in the Lifecycle Log. For more information to retrieve the configuration results see the Lifecycle Controller Remote Services Users Guide. Identify the unsuccessful configuration operations.
SYS037 Message Component update initialization failure. Detailed Description Operation validation is unsuccessful. The command, target and operation data are all validated before an update is performed. If any of them are missing or incorrect the operation does not complete successfully. Recommended Response Action Enable the Collect System Inventory on Restart attribute using Lifecycle Controller and restart the system. Retry the operation after the system restarts.
SYS039 Message Verification of requested configuration changes failed. Detailed Description The requested configuration changes have not passed the component specific verification checks, and therefore the changes will not be applied. Recommended Response Action Check the scripts or related documentation and retry the operation.
SYS041 Message Unable to apply some component configuration values. Detailed Description The configuration update is complete, however all of the values were not correctly applied. Recommended Response Action Check the Lifecycle Log for the values that were not set. Resolve the issues in the XML configuration input file and retry the operation. Alternatively, configure each of the attributes using the component service methods. For more information, see the Lifecycle Controller Users Guide.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS043 Message Successfully exported system configuration XML file. Detailed Description The current configuration of the system components (BIOS, RAID, NIC, iDRAC, and so on) was written to a system configuration XML file and successfully copied to the specified location. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS045 Message Unable to copy the system configuration XML file to the network share. Detailed Description An error occurred while copying the system configuration XML file to the network share. Recommended Response Action If the file is being exported to an NFS share, make sure that it is accessible from iDRAC.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS047 Message Input file for system configuration XML is not compliant with configuration schema. Detailed Description The input file is not compliant with the system configuration XML schema.
the system configuration schema published on delltechcenter.com/lc in the LC XML Schema Guide. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS050 Message The system configuration XML file for import configuration is not compliant with schema nesting checks.
Detailed Description Sometimes, the operating system on the server may not allow a graceful shutdown or may not complete within the specified graceful shutdown timeout. This error indicates that the system could not be shutdown within the time specified. The default timeout value is 5 minutes and the maximum value allowed is 1 hour. Recommended Response Action Retry the operation with a longer specified graceful shutdown timeout or with the system shutdown option.
SYS053 Message Successfully imported and applied system configuration XML file. Detailed Description Configuration changes specified in the system configuration XML file were successfully applied. Recommended Response Action No response action is required.
SYS055 Message Import of system configuration XML file operation completed with errors. Detailed Description The configuration specified in the system configuration XML file was applied, but there were some errors. The Lifecycle Controller Log contains the details of the component configurations that did not complete successfully. Recommended Response Action Review the Lifecycle Controller Log and identify the configuration changes that did not complete successfully.
SYS057 Message Exporting System Configuration Profile XML file. Detailed Description The current system configuration is being collected and the System Configuration Profile XML file is being generated. Recommended Response Action No response action is required.
SYS059 Message Component configuration successfully changed. Detailed Description Configuration changes for the component identified by the Fully Qualified Device Descriptor (FQDD) were successfully applied. Recommended Response Action No response action is required. See Lifecycle Log for details.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS061 Message Unable to complete component configuration. Detailed Description Some configuration changes for the component identified by the Fully Qualified Device Descriptor (FQDD) in the configuration job results were not successfully applied.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS063 Message Input file for import configuration operation is invalid. The expected root element was not closed. Detailed Description The input file for the import configuration operation does not contain a closed root element.
Category Configuration (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS065 Message Input file for import configuration operation cannot be found or opened. Detailed Description An internal error occurred opening the input configuration XML file. An iDRAC reset is required. Recommended Response Action Reset iDRAC and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS067 Message Unable to complete application of configuration XML file values. Detailed Description Some or all configuration actions during the import of configuration XML operation did not complete successfully. The configuration action details are logged into the Lifecycle Log. Recommended Response Action Export the Lifecycle Log and identify the configuration changes that did not successfully complete.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS069 Message No changes were applied since the current component configuration matched the requested configuration. Detailed Description The settings specified in the system configuration XML file match the current configuration for all components. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS071 Message System configuration XML export operation timed-out. Detailed Description The export of system configuration XML did not complete because the operation took too long.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS073 Message Unable to apply changes that require system reboot because the Lifecycle Controller State setting is disabled in the configuration XML. Detailed Description The import of system configuration XML file operation completed with errors because the Lifecycle Controller State was disabled in the input XML.
Severity Severity 2 (Warning) No alerts are applicable for this message SYS075 Message Unable to perform the import operation because the specified file does not exist on the remote share. Detailed Description Unable to perform the import operation because the specified file does not exist on the remote share. Recommended Response Action Make sure the import configuration file exists on the remote share before retrying the operation.
SYS078 Message Unable to retrieve the system configuration XML file from the network share for preview. Detailed Description Unable to retrieve the system configuration XML file from the network share for the requested preview operation. This may be due to issues with network accessibility. Recommended Response Action If the configuration XML file is on an NFS share, make sure that the network share is accessible from iDRAC.
Severity Severity 2 (Warning) No alerts are applicable for this message SYS081 Message Successfully previewed system configuration XML file import operation. Detailed Description Successfully previewed system configuration XML file import operation. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) No alerts are applicable for this message SYS084 Message Export of ePSA Diagnostics results did not complete successfully because the iDRAC internal storage containing the results could not be accessed. Detailed Description Export of ePSA Diagnostics results did not complete successfully because the iDRAC internal storage containing the results could not be accessed.
SYS087 Message A system reboot will occur when the previewed configuration XML file is imported to the system. Detailed Description When the configuration XML file specified in the Preview operation is imported to the system, a system reboot will occur to apply the configuration changes. Recommended Response Action No response action is required.
SYS090 Message The configuration XML input file contains unsupported DOCTYPE tags. Detailed Description The configuration XML Input file contains XML DOCTYPE tags which may contain injection security threats. The XML DOCTYPE tag is not supported in configuration XML files. Recommended Response Action Check the input XML file for DOCTYPE XML tags and remove them before retrying the operation.
Detailed Description The iDRAC is exporting the Tech Support Report to the specified destination. Recommended Response Action No response action is required. Category System Health (SYS = System Info) Severity Severity 3 (Informational) No alerts are applicable for this message SYS094 Message The iDRAC is unable to start the Tech Support Report job, because a report collection job is already running on the server.
Recommended Response Action Install the Dell 64bit uEFI Diagnostics firmware package, and then retry the operation. The Dell Diagnostics can be installed using the Dell 64bit uEFI Diagnostics Dell Update Package (DUP). Category System Health (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS097 Message The state of Lifecycle Controller is disabled by the configuration XML import operation.
Recommended Response Action Run the RunEPSADiagnostics method to make sure that the diagnostics results are available, and then retry the operation. Category System Health (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS100 Message Unable to find an FQDD equivalent for the token arg1 Arguments arg1 = token name Detailed Description A FQDD equivalent for the token name identified in the message cannot be found.
SYS1001 Message System is turning off. Detailed Description System is turning off. Recommended Response Action No response action is required. Category Audit (SYS = System Info) Severity Severity 3 (Informational) Trap/EventID 8579 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC SYS1002 Message System is performing a power cycle.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SYS1003 Message System CPU Resetting. Detailed Description System is performing a CPU reset because of system power off, power on or a warm reset like CTRL-ALT-DEL. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS102 Message Server Administrator Data Manager service has stopped. Detailed Description The Server Administrator Data manager service has stopped. Recommended Response Action Restart the Server Administrator Data Manager service.
OMSA Event ID 5001 OMSA Trap ID 5001 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS104 Message Server Administrator is starting. Detailed Description The Server Administrator is starting. Recommended Response Action No response action is required.
Recommended Response Action Contact your service provider. Category System Health (SYS = System Info) Severity Severity 2 (Warning) OMSA Event ID 5014 OMSA Trap ID 5014 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS106 Message An unknown system control action was initiated by the user.
SYS107 Message A system reboot was initiated by the user. Detailed Description The user initiated a system reboot. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS109 Message A system power cycle was initiated by the user. Detailed Description The user has initiated a system power cycle action. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS111 Message The actions Shutdown OS First and Power Off System were initiated by the user. Detailed Description The actions will shut down the operating system and then the system. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) OMSA Event ID 5007 OMSA Trap ID 5007 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS113 Message An invalid action was requested by the user. Detailed Description An invalid action was requested by the user. Recommended Response Action No response action is required.
Arguments arg1 = interface, arg2 = BMC, arg3 = SDR, arg4 = SEL Detailed Description IPMI is supported for identified interface, Baseboard Management Controller (BMC), Sensor Data Records (SDR), and System Event Log (SEL). Recommended Response Action If any status is not present, power cycle the system, and apply the latest firmware update packages for Lifecycle Controller and iDRAC.
SYS116 Message Unable to determine the status of the power cord. Detailed Description The status of the power cord cannot be determined because of one of the following reasons: 1) The power cable may not be connected properly or disconnected. 2) The power cord sensor in the power supply unit has failed. However, the power supply unit may still function. 3) There is an input power failure.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS118 Message The input power supply is not available. Detailed Description The input power supply is not available because of one of the following reasons: 1) The power cable may not be connected properly or disconnected. 2) There is an input power failure. Recommended Response Action Do of the following to resolve the issue: 1) Reconnect the power cord to the power supply unit.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS120 Message Unable to complete the operation because the OS Collector is taking too much time. The operation is cancelled. Detailed Description The OS Collector application did not complete its task within the maximum allowed time and the operation is cancelled. This may be because the server OS is not supported by the OS Collector application and the application is unable to function correctly.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS122 Message OS Collector: The operation to collect OS and Application Data is successfully completed. Detailed Description The operation to collect OS and Application Data is successfully completed. Recommended Response Action No response action is required.
Category System Health (SYS = System Info) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS124 Message OS Collector: The OS Collector application does not support execution in the OS installed on the server.
Recommended Response Action Do the following: 1) Make sure the user context the OS Collector application is running in has the appropriate privileges to access WMI. Make sure that firewall or security settings are set to allow access and retry the operation. 2) If the issue persists, restart the WMI service and retry the operation. 3) If the issue continues to persists, restart the server OS and retry the operation.
Detailed Description OS log data was not collected. An issue occurred while collecting OS log data because of an unknown exception. Recommended Response Action Do the following: 1) Retry the operation. 2) If the issue persists, reinstall the latest OS Collector on the iDRAC, and then retry the operation.
Detailed Description Unable to complete XML transform on the data collected because the collected data is in an unexpected format. Recommended Response Action Do the following: 1) Retry the operation. 2) If the issue persists, reinstall the latest OS Collector on the iDRAC, and then retry the operation.
Detailed Description Unable to communicate with the OS IPMI service because the service is not running. Recommended Response Action For more information about checking whether the IPMI service is running, see the iDRAC8 Users Guide.
Detailed Description An issue was encountered while creating an IPMI session. Recommended Response Action Restart the WMI service and retry the operation. Category System Health (SYS = System Info) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS134 Message OS Collector: Zip archive size exceeded the limit.
Detailed Description The user context the OS Collector is being run in does not have the necessary privileges for running the application successfully. Recommended Response Action Run the OS Collector application as administrator or as a user added to admin group or domain administrator or Local administrator.
SYS137 Message Unable to start the collection of OS and Application Data because the Lifecycle Controller is not enabled. Detailed Description Unable to start the collection of OS and Application Data because the Lifecycle Controller is not enabled. Recommended Response Action Enable the Lifecycle Controller by pressing F2 during server startup and select iDRAC Settings > Lifecycle Controller and then enable the Lifecycle Controller. Retry the operation after the server has restarted.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS139 Message Unable to start the collection of OS and Application Data because the server is in POST and has not finished startup. Detailed Description Unable to start the collection of OS and Application Data because the server is in POST and has not finished startup. Recommended Response Action Retry the operation after the server has finished starting and POST has completed.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS141 Message Lifecycle Controller data is deleted. Detailed Description The Lifecycle Controller data is deleted because of a System Erase operation. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS143 Message ePSA Diagnostics are deleted. Detailed Description ePSA Diagnostics are deleted because of a System Erase operation. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS145 Message vFlash SD Card data is deleted. Detailed Description vFlash SD Card data is deleted because of a System Erase operation. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS147 Message Starting non-secure erase-capable drive erase operations. Detailed Description Starting non-secure erase-capable drives erase operations because of a System Erase operation request. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS149 Message The process of resetting iDRAC to default settings is initiated. Detailed Description Initiating iDRAC reset to defaults operation because of a System Erase operation. The iDRAC will restart after firmware default values are restored. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS151 Message Completed System Erase Job ID: arg1 Arguments arg1 = job ID Detailed Description A System Erase job with the job ID identified in the message is completed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS153 Message Deleting hardware cache data for controller: arg1 . Arguments arg1 = device name Detailed Description The non-volatile cache of the controller identified in the message is being erased. Recommended Response Action No response action is required.
Category Configuration (SYS = System Info) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS155 Message Initiating clear operation on non-secure erase-capable drives for controller: arg1 .
Category Configuration (SYS = System Info) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS157 Message Unable to successfully complete requested System Erase tasks. Detailed Description Unable to successfully complete requested options of the System Erase operation. Retrying the System Erase operation may be required.
Recommended Response Action Retry the System Erase operation with only the hardware cache erase option selected. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS159 Message vFlash SD Card erase unsuccessful. Detailed Description The vFlash SD Card erase operation was unsuccessful.
Recommended Response Action No response action is required. Category Configuration (SYS = System Info) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS161 Message Tech Support Report related non-volatile storage deleted.
Recommended Response Action No response action is required. Category Configuration (SYS = System Info) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS163 Message The iDRAC is restarting to complete the System Erase operation. Do not restart server until the iDRAC restarts.
Detailed Description The System Erase operation attempted to access Lifecycle Controller internal storage that is already being accessed by another function. Exclusive access to the internal storage is required for the System Erase operation. The System Erase operation attempts Lifecycle Controller internal storage access for 10 minutes. After the timeout the current job completes with an unsuccessful status.
retry the operation. 4) Make sure the OS is supported by the OS Collector application. 5) Reinstall the latest OS Collector on the iDRAC, and then retry the operation. 6) For more information about the collection of OS and application data, see the iDRAC8 Users Guide. Category System Health (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS167 Message TTY Log data export did not complete within the allocated time.
Severity Severity 2 (Warning) No alerts are applicable for this message SYS170 Message The SHA256 Hash value and the clear text value for an iDRAC user password cannot be entered together. Detailed Description The SHA256 Hash value and the clear text value for an iDRAC user password cannot be used at the same time for a password configuration operation. Recommended Response Action Make sure that the user password is configured using either the clear text or the SHA256 Hash, but not both.
SYS173 Message Unable to retrieve the TTY Log because another operation is in progress on the RAID controller. Detailed Description The TTY Log cannot be retrieved because another operation is in progress on the RAID controller. Recommended Response Action Do the following: 1) View the job queue and make sure all jobs are in a completed state. 2) Retry the operation.
SYS177 Message There was an issue retrieving Hardware data. Detailed Description There was an issue retrieving Hardware data from the iDRAC internal storage. This may be because Collect System Inventory on Restart (CSIOR) feature is disabled and has never executed or the iDRAC Remote Services API status may not be in the Ready state. Recommended Response Action Make sure the Collect System Inventory on Restart (CSIOR) is enabled and has run at least once before retrying this operation.
SYS180 Message There was an issue encountered when attempted to export TTY Log data for the storage controller arg1 . Arguments arg1 = controller name Detailed Description The TTY log data of the storage controller identified in the message cannot be exported because an issue was encountered while communicating with the controller. Recommended Response Action While exporting the TTY log, make sure that the server is not in BIOS POST, and then retry the operation.
SYS182 Message Unable to collect OS and Application Data because another Lifecycle Controller operation is currently in progress. Detailed Description Collecting OS and Application Data cannot be completed because Lifecycle Controller is used by another operation. Recommended Response Action Make sure all other Lifecycle Controller operations are finished and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS184 Message Unable to compute the checksum because OS Collector files are not readable. Detailed Description The checksum cannot be computed because OS Collector files are not readable. Recommended Response Action Reinstall the OS Collector in the iDRAC and retry the operation.
SYS186 Message Unable to start the collection of TTY log data because the server is turned off. Detailed Description Unable to start the collection of TTY log data because the server OS is turned off. Recommended Response Action Turn on the server and wait until the OS finishes booting, and then retry the operation.
Detailed Description There is no cached copy of OS and Application data in the iDRAC flash storage. Recommended Response Action Collect the OS and Application Data either manually or automatically using the iDRAC Services Module (ISM) tools and then retry the operation.
Recommended Response Action Check the Lifecycle Log report to analyze the issue. Review settings and branding information that the ID module configured, resolve the issue, and then retry the installation process. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS197 Message Unable to install the OEM ID module because of some issues. Detailed Description The OEM ID module cannot be installed because of some issues.
LC Log iDRAC ✔* CMC ✔* 1936 LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔*
62 TMP Event Messages TMP0100 Message The system board arg1 temperature is less than the lower warning threshold. Arguments arg1 = name Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
LCD Message iDRAC System board temperature is outside of range. Check Fans Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0102 Message The system board arg1 temperature is greater than the upper warning threshold. Arguments arg1 = name Detailed Description Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message System board temperature is outside of range.
TMP0105 Message The system board arg1 temperature is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC TMP0107 Message The memory module arg1 temperature is less than the lower critical threshold. Arguments arg1 = number Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
Trap/EventID iDRAC 2162 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0109 Message The memory module arg1 temperature is greater than the upper critical threshold. Arguments arg1 = number Detailed Description Ambient air temperature is too warm or one or more fans may have failed.
Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message Memory module temperature is outside of range.
TMP0112 Message The arg1 temperature is less than the lower warning threshold. Arguments arg1 = name Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* TMP0114 Message The arg1 temperature is greater than the upper warning threshold. Arguments arg1 = name Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* TMP0116 Message The arg1 temperature is outside of range. Arguments arg1 = name Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures.
Recommended Response Action No response action is required. Category System Health (TMP = Temperature) Severity Severity 3 (Informational) Trap/EventID 2163 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* TMP0118 Message The system inlet temperature is less than the lower warning threshold.
Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message Inlet temperature is lower than critical threshold.
TMP0121 Message The system inlet temperature is greater than the upper critical threshold. Detailed Description Ambient air temperature is too warm. Recommended Response Action Check system operating environment. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message Inlet temperature is greater than upper critical threshold.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* TMP0123 Message The system inlet temperature is within range. Detailed Description None Recommended Response Action No response action is required.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0125 Message Disk drive bay temperature is less than the lower critical threshold. Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
Trap/EventID iDRAC 2162 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0127 Message Disk drive bay temperature is greater than the upper critical threshold. Detailed Description Ambient air temperature is too warm or one or more fans may have failed.
Severity Severity 1 (Critical) Trap/EventID 2161 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0129 Message Disk drive bay temperature is within range. Detailed Description None Recommended Response Action No response action is required.
Category System Health (TMP = Temperature) Severity Severity 2 (Warning) Trap/EventID 2162 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy TMP0131 Message The control panel temperature is less than the lower critical threshold. Detailed Description Ambient air temperature is too cool.
Recommended Response Action Check system operating environment and review event log for fan failures.
Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures.
TMP0136 Message The system is automatically turned off because of insufficient cooling. Detailed Description The system is automatically turned off because of insufficient cooling. Recommended Response Action Replace the fans that have stopped functioning, or add the minimum number of fans recommended. For more information, see the system Owners Manual available at the support site.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC TMP0138 Message The C1 Enhance (C1E) state is disabled in the server. Increased fan speeds can be expected during high CPU workload. Detailed Description Disabling the C1E state in servers with processors that have their Thermal Design Power (TDP) value set to equal to or greater than 155 Watt results in increased fan speed during high CPU workloads. Recommended Response Action No response action is required.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0201 Message CPU arg1 temperature is less than the lower critical threshold. Arguments arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment.
Recommended Response Action Check system operating environment, fans, and heatsinks. Category System Health (TMP = Temperature) Severity Severity 2 (Warning) Trap/EventID 2162 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0203 Message CPU arg1 temperature is greater than the upper critical threshold.
TMP0204 Message CPU arg1 temperature is outside of range. Arguments arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment, fans, and heatsinks. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message CPU temperature is outside of range.
LC Log iDRAC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC TMP0300 Message The Enhanced Cooling Mode feature is enabled. Detailed Description The Enhanced Cooling Mode feature is enabled. Recommended Response Action No response action is required. Category System Health (TMP = Temperature) Severity Severity 3 (Informational) No alerts are applicable for this message TMP0301 Message The Enhanced Cooling Mode feature is disabled.
Severity Severity 2 (Warning) No alerts are applicable for this message TMP1000 Message arg1 exceeded the maximum warning threshold. Arguments arg1 = tempsensor name Detailed Description The enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot. Recommended Response Action Check for factors that may cause overheating.
Severity Severity 2 (Warning) Trap/EventID 4210 OMSA Event ID 2101 OMSA Trap ID 105300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* TMP1002 Message arg1 has exceeded the maximum failure threshold. Arguments arg1 = tempsensor name Detailed Description The enclosure is too hot.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* TMP1003 Message arg1 has crossed the minimum failure threshold. Arguments arg1 = tempsensor name Detailed Description The enclosure is too cold. Recommended Response Action Check whether the thermostat setting is too low and whether the room temperature is too cool.
Trap/EventID Filter Visibility 4211 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* TMP5 Message The temperature probe maximum warning value was changed on arg1 . Arguments arg1 = Enclosure name Detailed Description You have changed the value for the maximum temperature probe warning threshold. This alert is provided for informational purposes.
Detailed Description A temperature sensor identified in the message has failed. This condition can cause system performance issues and degradation in the monitoring capability of the system. Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC TMP502 Message The arg1 sensor has returned to a normal state with a value of arg2 degrees Celsius. Arguments arg1 = sensor name, arg2 = temperature Detailed Description The sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required.
temperature sensor (if applicable) such that it corresponds to the hardware configuration. Category System Health (TMP = Temperature) Severity Severity 2 (Warning) OMSA Event ID 5053 OMSA Trap ID 5053 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC TMP504 Message The arg1 sensor has detected an error with a value of arg2 degrees Celsius.
TMP505 Message The arg1 sensor has failed with a value of arg2 degrees Celsius. Arguments arg1 = sensor name, arg2 = temperature Detailed Description The temperature sensor identified in the message has failed. Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* TMP7 Message arg1 has failed. Arguments arg1 = Temp Sensor Name Detailed Description A device has been failed and the system is no longer functioning in optimal condition. Recommended Response Action Replace the device.
Recommended Response Action Check the chassis event log for fan issues and fix any issues present. If no fan issues are detected, check chassis ambient temperature and make sure the temperature is within operating range. Utilize the RACADM command "racadm getsensorinfo" to check the chassis ambient temperature.
Detailed Description The system has recovered from being unable to read planar board or control panel temperature sensors. Recommended Response Action No response action required.
63 TMPS Event Messages TMPS0100 Message Inlet temperature is above warning level for extended duration. Detailed Description Inlet temperature has been above the warning threshold for duration of 8% or more for the operational time during the last one year. Recommended Response Action This condition will occur if the ambient temperature is high. Make sure the ambient temperature of the environment is in normal range.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC TMPS0102 Message Inlet temperature is above warning level for extended duration. Detailed Description Inlet temperature has been above the warning threshold for duration of 10% or more for the operational time during the last one year.
Trap/EventID Filter Visibility iDRAC 2521 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC CMC 1976 ✔* LCD ✔ Reset Chassis Event Proxy
TST Event Messages 64 TST100 Message The operation was successful. Detailed Description The operation completed successfully. Recommended Response Action No response action is required. Category Configuration (TST = Test Alert) Severity Severity 3 (Informational) No alerts are applicable for this message TST101 Message Resource allocation failure. Detailed Description The operation did not complete successfully because of lack of memory or file space in the iDRAC firmware.
TST103 Message Missing parameters arg1 Arguments arg1 = parameter names Detailed Description One or more required parameters needed for the operation are missing. Recommended Response Action To provide the correct parameters, see Lifecycle Controller-Remote Services documentation. Category Configuration (TST = Test Alert) Severity Severity 2 (Warning) No alerts are applicable for this message TST104 Message SNMP traps not configured.
TST106 Message Email alert destination address not configured. Detailed Description The email alert being tested is not properly configured. Recommended Response Action Configure the email alert and retry the operation. If the failure persists, reset iDRAC.
65 UEFI Event Messages UEFI0000 Message CPU Exception Type 0x00: Divide by Zero (Software). Detailed Description A CPU type 0x00, divide by zero exception, (type 0x00) occurred in the pre-boot UEFI environment. The software attempted to do a mathematical divide by zero, an illegal operation. Recommended Response Action Recently installed hardware or updated software may cause this exception.Update or remove the hardware or software.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0004 Message CPU Exception Type 0x06: Invalid Opcode (Software). Detailed Description A CPU invalid opcode exception (type 0x06) occurred in the pre-boot UEFI environment. The software attempted to execute invalid code.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0006 Message CPU Exception Type 0x08: Double Fault (Software). Detailed Description A CPU double fault exception (type 0x08) occurred. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0008 Message CPU Exception Type 0x0A: Invalid Task Segment State Segment (TSS) (Software). Detailed Description A CPU invalid task segment state (TSS) exception (type 0x0A) occurred in the preboot UEFI environment.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0010 Message CPU Exception Type 0x0C: Stack-Segment Fault (Software). Detailed Description A CPU stack-segment fault (type 0x0C) exception occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0012 Message CPU Exception Type 0x0E: Page Fault (Software). Detailed Description A CPU page fault (type 0x0E) exception occurred in the pre-boot UEFI environment. A program accessed a page mapped in the virtual address space, but not loaded in physical memory.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0014 Message CPU Exception Type 0x11: Alignment Check (Software). Detailed Description A CPU alignment check exception (type 0x11) occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0016 Message Lifecycle Controller (LC) firmware was not accessible and is therefore in Recovery mode. Detailed Description Unable to find a Lifecycle Controller partition.
Detailed Description Unable to locate a file required to run Lifecycle Controller. No Lifecycle Controller functionality is available while in Recovery Mode. Recommended Response Action Repair Lifecycle Controller firmware using the Lifecycle Controller Dell Update Package (DUP) or Lifecycle Controller Repair Package via iDRAC. For more information, see Lifecycle Controller Users Guide.
UEFI0019 Message Lifecycle Controller (LC) is unable to complete a requested task or function and prevented the boot process from completing on multiple attempts. LC is in Recovery Mode. Detailed Description The system boot process did not complete repeatedly due to problems encountered while performing a Lifecycle Controller task for function. No Lifecycle Controller functionality is available while in Recovery Mode.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0021 Message The Lifecycle Controller feature is disabled. Detailed Description The Lifecycle Controller feature is disabled. The feature was disabled because of one of the following conditions: 1) The feature was disabled manually using the F2 System Setup utility or through an iDRAC interface, 2) BIOS encountered an issue starting the feature and automatically disabled it.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0023 Message BIOS is unable to send the End of POST message to Management Engine because the Management Engine is not responding. Detailed Description The End of POST message could not be sent to the Management Engine because the Management Engine is not responding.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0025 Message Unable to initialize Management Engine firmware. Detailed Description The Management Engine firmware cannot be initialized. The BIOS will reset the system to retry the initialization process. Recommended Response Action Wait for the BIOS to reset the system and reinitialize the Management Engine.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0027 Message The system must be restarted for the new license to become effective. Detailed Description A license change for the system or a component in the system requires a system reset in order for the new license to take effect. Recommended Response Action Wait for the BIOS to reset the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0029 Message Unable to initialize iDRAC because of some critical issues. Detailed Description iDRAC could not be initialized because of some critical issues.
Recommended Response Action Connect a keyboard device to the system. Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0031 Message PCIe downtrain is detected on arg1 .
Detailed Description The TPM chip cannot be initialized because the TPM chip is not functioning. Recommended Response Action Remove input power from the system, wait for 30 seconds, and re-apply input power. Turn on the system.
UEFI0034 Message A CMOS battery loss is detected resulting in an invalid BIOS configuration. Detailed Description A CMOS battery loss is detected resulting in an invalid BIOS configuration. Recommended Response Action Go to the System Setup to configure system settings, system time and date.
UEFI0036 Message Unable to initialize the iDRAC Shared Memory Architecture (SMA) interface. Detailed Description The iDRAC Shared Memory Architecture (SMA) interface cannot be initialized. The BIOS will use the Keyboard Controller Style (KCS) interface. Recommended Response Action Do one of the following: 1) Remove input power from the system, wait for 30 seconds, and re-apply input power. Turn on the system. 2) Update the iDRAC firmware on the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0038 Message Unable to communicate with iDRAC because of missing interrupts on the Shared Memory Architecture (SMA) interface. Detailed Description Unable to communicate with iDRAC because an expected interrupt(s) from the iDRAC SMA (Shared Memory Architecture) interface did not happen.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0040 Message The TXT feature is disabled because of an unexpected issue. Detailed Description The TXT has been disabled due to an unexpected issue. Check the SEL (System Event Log) for details of the issue.
Recommended Response Action From System Setup, enable VT, and then enable TXT. If the issue persists, update the system BIOS firmware.
Detailed Description Unable to enable the TXT feature because the processor does not support TXT. Recommended Response Action Install a TXT-capable processor and retry the operation.
Detailed Description Unable to enable the TXT feature because a TPM chip is not present. Recommended Response Action Install a TPM chip module by following the installation procedure. Refer to the platform Owners Manual for more information or contact your service provider.
UEFI0047 Message One or more keys in the keyboard is stuck and not functional. Detailed Description One or more keys in the keyboard is stuck and not functional. Recommended Response Action Make sure that the key is not stuck in the keyboard and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0049 Message Unable to enable the Non-maskable Interrupt (NMI) button because either the NMI button is stuck or iDRAC firmware is not updated. Detailed Description The NMI button cannot be enabled because either the NMI button is stuck or iDRAC firmware is not updated. Recommended Response Action Correct the NMI button if stuck or update iDRAC firmware on the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0051 Message Brand information is successfully collected. The system is being restarted. Detailed Description Brand information is successfully collected. The system is being restarted. The rebranding process is completed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0053 Message The debranding process is started. Detailed Description The debranding process is started. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0055 Message Unable to complete the debranding operation because of the issue(s) displayed earlier. Detailed Description The debranding process cannot be completed because of the reasons identified on the computer screen. Recommended Response Action Check the screen display for details of the failure. Retry the debrand process again, or update the system BIOS and then retry.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0057 Message A Machine-Check Exception (MCE) error has occurred. Detailed Description The MCE is logged during Power-on-Self-Test (POST). MCE could have occurred during either the current or the previous POST. Recommended Response Action Check the System Event Log (SEL) to identify Machine-Check Exception (MCE) event source. Resolve the issue identified in the SEL that caused the MCE.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0059 Message The Power Supply Units (PSUs) in the system do not match. Detailed Description The Power Supply Units (PSUs) in the system do not match. Recommended Response Action Check the PSU types and make sure they are appropriately matched, and then retry the operation. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0061 Message The request to change attributes is being processed. Detailed Description The request to change one or more attribute(s) is being processed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0063 Message Unable to change an attribute because of issues in the Attribute Configuration Interface (ACI) data block. Detailed Description An attribute cannot be successfully configured because of an issue in the ACI data block. Recommended Response Action Check the ACI data block for any invalid configuration data and settings, and then retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0065 Message One or more attributes are successfully configured. The system will be automatically turned off in 5 seconds. Detailed Description One or more attributes are successfully configured. The system is automatically turned off in 5 seconds. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0067 Message A PCIe link training failure is observed in arg1 and device link is disabled. Arguments arg1 = PCIe device Detailed Description A PCIe link failure is observed in the PCIe device identified in the message and device link is disabled.
Category Configuration (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0069 Message A CMOS checksum error has occurred. CMOS is reinitialized. Detailed Description A CMOS checksum error has occurred resulting in an invalid BIOS configuration. BIOS configuration is reset to default settings.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0071 Message One or more UEFI network interfaces is not available. The corresponding UEFI network devices are disabled. Detailed Description One or more UEFI network interfaces is not available. The corresponding UEFI network devices are disabled.
certificate. The policy may also authorize hash values of individual UEFI driver images. Users can configure the Secure Boot feature and the Secure Boot policy in F2 System Setup > System BIOS > Security Settings page. Recommended Response Action If the Secure Boot feature is not desired, disable it in System Setup > System BIOS > Security Settings page. Otherwise, do the following: 1) Make sure the firmware on the failing device is up-to-date.
Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0074 Message The Secure Boot policy has been modified since the last time the system was started. Detailed Description The system BIOS logs this message after detecting a change in Secure Boot policy settings.
Detailed Description The Network Daughter Card 1 is not detected. Recommended Response Action Install a Network Daughter Card in the system. Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0076 Message One or more Corrected Machine Check(CMC) errors have occurred.
Detailed Description One or more PCIe device errors occurred in the previous boot. Recommended Response Action Check the System Event Log (SEL) to identify the PCIe device with errors, and then update its firmware.
Detailed Description One or more Uncorrectable Memory errors occurred in the previous boot. Recommended Response Action Check the System Event Log (SEL) to identify the non-functional DIMM, and then replace the DIMM.
UEFI0081 Message Memory size has changed from the last time the system was started. Detailed Description Memory size has changed from the last time the system was started. No action is required if memory was added or removed. Recommended Response Action If the change is expected, no action is necessary. Otherwise, check the DIMM population inside the system and memory settings in System Setup for configuration changes. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0083 Message One or more PCI System errors (SERR) have occurred. Detailed Description One or more PCI System errors (SERR) have occurred. Recommended Response Action Check the System Event Log (SEL) to identify the PCI device that caused the SERR. Update the identified device firmware. If the issue persists, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0085 Message One or more chipset errors have occurred. Detailed Description One or more chipset errors have occurred. Recommended Response Action Check the System Event Log (SEL) to identify the chipset error. Do one of the following: 1) Turn off the input power to the system and turn on again. 2) Update the PCIe device firmware. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0087 Message Unsupported 4Gb technology DIMM module is installed on memory slot: arg1 . Arguments arg1 = slot number Detailed Description Unsupported 4Gb technology DIMM module is installed on the memory slot identified in the message.
Category Configuration (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0089 Message Incompatible x16 data bus width DIMM is installed on memory slot: arg1 . Arguments arg1 = slot number Detailed Description Incompatible x16 data bus width DIMM is installed on the memory slot identified in the message.
Recommended Response Action Remove the unsupported DIMM module from the identified memory slot and replace it with a supported module. For more information, see the platform Owners Manual.
UEFI0092 Message The number of DIMM ranks has exceeded the maximum allowed ranks per channel limit. Detailed Description The number of DIMM ranks has exceeded the maximum allowed ranks per channel limit. Recommended Response Action Check the total number of ranks in each channel to make sure it does not exceed the maximum allowed limit. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0094 Message Unsupported Non-ECC memory module is installed on memory slot: arg1 . Arguments arg1 = slot number Detailed Description Unsupported Non-ECC memory module is installed on the memory slot identified in the message. Recommended Response Action Remove all Non-ECC DIMMs and replace them with ECC DIMMs. For more information, see the platform Owners Manual.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0096 Message Unable to enable the Advanced ECC memory operating mode because the current DIMM population or system configuration does not support Advanced ECC mode.
Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0098 Message The memory Built-In Self-test (BIST) has detected one or more errors on the DIMM installed on memory slot: arg1 . As a result, the corresponding DIMM has been disabled.
Detailed Description The Memory Mirroring feature cannot be enabled because the current DIMM population or hardware configuration does not support the feature. Recommended Response Action Check the DIMM population and hardware configuration to make sure the Memory Mirroring feature can be supported. For more information, see platform Owners Manual.
UEFI0101 Message Total amount of installed memory has exceeded limit. Detailed Description The total amount of installed memory has exceeded the amount supported by the platform. Recommended Response Action Remove memory modules from the system to reduce the total amount of installed memory. For more information on installed memory limit, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0103 Message One or more memory initialization errors have occurred on memory slot: arg1 . Arguments arg1 = slot Detailed Description One or more memory initialization error have occurred on the memory slot identified in the message. Recommended Response Action Replace the faulty memory module identified in the message.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0105 Message Unable to enable the Cluster on Die (COD) feature because of an unsupported memory configuration. Detailed Description The Cluster on Die (COD) feature cannot be enabled because of an unsupported memory configuration.
Category System Health (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0107 Message One or more memory errors have occurred on memory slot: arg1 . Arguments arg1 = slot Detailed Description One or more memory errors have occurred on the memory slot identified in the message.
Recommended Response Action Remove input power to the system, reseat the DIMM module and restart the system. If the issues persist, then replace the faulty memory module identified in the message.
Arguments arg1 = slot Detailed Description One or more memory errors have occurred on memory slot identified in the message. The error occurred during Write DQ/DQS initialization. Recommended Response Action Remove input power to the system, reseat the DIMM module and restart the system. If the issues persist, then replace the faulty memory module identified in the message.
UEFI0112 Message One or more memory errors have occurred on memory slot: arg1 . Arguments arg1 = slot Detailed Description One or more memory errors have occurred on memory slot identified in the message. The error occurred during the LRDIMM interface initialization. Recommended Response Action Remove input power to the system, reseat the DIMM module and restart the system. If the issues persist, then replace the faulty memory module identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0114 Message Unable to enable the Fault Resilient Memory (FRM) operating mode because of mismatches in DIMM channel configurations. Detailed Description The Fault Resilient Memory (FRM) operating mode cannot be enabled because of mismatches in DIMM channel configurations. Recommended Response Action Make sure identical memory modules in corresponding slots of channel pairs are populated.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0116 Message One or more boot drivers have reported issue(s). Detailed Description One or more boot drivers have reported issue(s) via the UEFI Driver Health Protocol. Recommended Response Action Check the Driver Health Menu in Boot Manager for details.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0118 Message Card identification signature is not present on Internal Dual Secure Digital Module (IDSDM) SD card 2. Detailed Description Card identification signature is not present on Internal Dual Secure Digital Module (IDSDM) SD card 2.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0120 Message Both of the Internal Dual Secure Digital Module (IDSDM) SD card media are missing, or not responding. Detailed Description Both of the Internal Dual Secure Digital Module (IDSDM) SD card media are missing, or not responding.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0122 Message The secondary SD card is missing, not responding, or in write-protected mode. Detailed Description The secondary SD card is missing, not responding, or in write-protected mode. Recommended Response Action Do one of the following: 1) Install a SD card media in the secondary SD card slot.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0124 Message The size and speed of the secondary SD card do not match those of the primary SD card. Detailed Description The size and speed of the primary SD card do not match those of the secondary SD card. The secondary SD card needs to have equal or greater capacity and speed than the primary SD card.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0126 Message The primary SD card is in write-protected mode. Detailed Description The primary SD card is in write-protected mode. Recommended Response Action No response action is required if this is intentional.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0128 Message Both the primary and secondary SD cards are in write-protected mode. Detailed Description Both the primary and secondary SD cards are in write-protected mode. Recommended Response Action No response action is required if this is intentional.
Recommended Response Action Do one of the following: 1) Update the system BIOS. 2) Update the iDRAC firmware. 3) Reseat or replace the SD card media. Restart the system and retry the operation. If the issue persists, contact your service provider.
Recommended Response Action Do one of the following: 1) Remove unused PCIe card(s) to free up option ROM space. 2) Disable unused boot protocol instances (such as PXE, iSCSI, etc.) from applicable PCIe card(s) option ROM configurations. 3) If possible, install and run the Operating System in UEFI boot mode.
UEFI0133 Message Unable to perform PXE boot because the VLAN settings conflict with that of the iSCSI device settings. Detailed Description Unable to perform PXE boot because the VLAN settings conflict with that of the iSCSI device settings. Recommended Response Action Do one of the following: 1) Go to System Setup and change the VLAN configuration for the PXE device to match that of the iSCSI device.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0135 Message Unable to execute CSIOR (Collect System Inventory on Restart) because the Lifecycle Controller (LC) firmware was not accessible. Detailed Description The CSIOR (Collect System Inventory on Restart) operation cannot be executed because the Lifecycle Controller (LC) firmware was not accessible. This issue is caused by LC partition attach issues.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0137 Message Unable to execute CSIOR (Collect System Inventory on Restart) because the Lifecycle Controller (LC) firmware was not accessible. Detailed Description The CSIOR (Collect System Inventory on Restart) operation cannot be executed because the Lifecycle Controller (LC) firmware was not accessible.
Category System Health (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0139 Message Unable to enter System Service Mode (SSM) because the Lifecycle Controller (LC) firmware was not accessible.
Recommended Response Action Do one of the following: 1) Restart the system and retry the operation. 2) Update the iDRAC firmware. If the issue persists, contact your service provider.
Detailed Description The System Service Mode (SSM) cannot be entered because the Lifecycle Controller (LC) firmware was unable to complete a requested task or function. Recommended Response Action Do one of the following: 1) Restart the system and retry the operation. 2) Update the iDRAC firmware. If the issue persists, contact your service provider.
Detailed Description One or more memory errors have occurred on memory slot identified in the message. The error happens during the identification of memory module type or memory size. Recommended Response Action Remove input power to the system, reseat the DIMM module and restart the system. If the issues persist, replace the faulty memory module identified in the message.
UEFI0146 Message Unable to verify the chassis type via iDRAC and CMC. System configuration may be incorrect as a result. Detailed Description Unable to verify the chassis type via iDRAC and CMC. System configuration may be incorrect as a result. Recommended Response Action Do one of the following: 1) Restart the system. 2) Update the iDRAC firmware and then restart the system. If the issue persists, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0148 Message The SAS cable arg1 for the primary SAS expander daughter card is missing or misconfigured. Arguments arg1 = label number Detailed Description The SAS cable for the primary SAS expander daughter card is missing or misconfigured. Recommended Response Action Check the cable configuration. For more information, see the platform Owners Manual.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0150 Message The system has detected a storage backplane that is not supported in this system or configuration. The backplanes functionality may be degraded or disabled. Detailed Description The system has detected a storage backplane that is not supported in this system or configuration.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0152 Message This BIOS is for testing purpose only. Detailed Description This is a test BIOS and must not be used in production environment. Recommended Response Action Do not use this BIOS in production.
Recommended Response Action Do one of the following: 1) Reload the license. 2) Remove input power from the system, wait for 30 seconds, and re-apply input power. Turn on the system. 3) Update the iDRAC firmware.
UEFI0155 Message Unable to find the Dell Processor Acceleration Technology (DPAT) Enterprise license after three consecutive boots. The Number of Cores per Processor BIOS setup configuration is being reverted to default because of the absent license. Detailed Description Unable to find the Dell Processor Acceleration Technology (DPAT) Enterprise license after three consecutive boots. The Number of Cores per Processor BIOS setup configuration is being reverted to default because of the absent license.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0157 Message The iDRAC request to reset BIOS to default settings is successfully completed. Detailed Description The request to reset BIOS to default settings is successfully completed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0159 Message Unsupported Unregistered Dual In-line Memory Module (UDIMM) memory is installed on memory slot: arg1 Arguments arg1 = slot number Detailed Description Unsupported 4Gb technology DIMM module is installed on the memory slot identified in the message.
Recommended Response Action Check the total number of ranks in the channel to make sure it does not exceed the maximum allowed limit. For more information, see the platform Owners Manual.
Detailed Description An incompatibility has been detected between an installed memory buffer and the downstream DDR channel design. Recommended Response Action Contact your service provider.
UEFI0164 Message Unable to enable the Advanced ECC memory operating mode because of mismatches in the DIMM channel configurations on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description The Advanced ECC memory operating mode cannot be enabled because of mismatches in the DIMM channel configurations. Recommended Response Action Make sure identical memory modules in corresponding slots of channel pairs are populated. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0166 Message Unable to configure memory interleaving on DIMM modules on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description Memory could not be interleaved because the number of allowable Target Address Decode (TAD) rules exceeded during memory initialization. Recommended Response Action Check the DIMM population and hardware configuration to make sure interleaving can be supported.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0168 Message Unable to configure memory interleaving on DIMM modules on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description Memory could not be interleaved because a negative Target Address Decode (TAD) offset was calculated during memory initialization.
Recommended Response Action Check the DIMM population and hardware configuration to make sure interleaving can be supported. For more information, see the platform Owners Manual.
UEFI0171 Message A Dual Rank DIMM module is installed on memory slot arg1 after a Single Rank DIMM module. Arguments arg1 = slot number Detailed Description A memory population violation has been detected on the identified DIMM slot. Recommended Response Action Dual Rank DIMM modules must be installed before Single Rank DIMM modules on the channel. Populate memory modules in a supported configuration. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0173 Message A Quad Rank DIMM module is installed on memory slot arg1 after a Dual Rank DIMM module. Arguments arg1 = slot number Detailed Description A memory population violation has been detected on the identified DIMM slot. Recommended Response Action Quad Rank DIMM modules must be installed before Dual Rank DIMM modules on the channel. Populate memory modules in a supported configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0175 Message A Octal Rank DIMM module is installed on memory slot arg1 after a Quad Rank DIMM module. Arguments arg1 = slot number Detailed Description A memory population violation has been detected on the identified DIMM slot.
Recommended Response Action Only a single Quad Rank DIMM module can be installed on a channel. Populate memory modules in a supported configuration. For more information, see the platform Owners Manual.
UEFI0178 Message One or more memory correctable training errors have occurred on memory slot: arg1 . Arguments arg1 = slot number Detailed Description One or more memory correctable training errors have occurred on the memory slot identified in the message. A corrected Read DQ/DQS error was detected. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0180 Message One or more memory correctable training errors have occurred on memory slot: arg1 . Arguments arg1 = slot number Detailed Description One or more memory correctable training errors have occurred on the memory slot identified in the message. A corrected Write Leveling error was detected.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0182 Message One or more memory correctable training errors have occurred on memory slot: arg1 . Arguments arg1 = slot number Detailed Description One or more memory correctable training errors have occurred on the memory slot identified in the message. A corrected Early Vref Centering error was detected.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module identified in the message.
UEFI0185 Message Load Reduced DIMM (LR-DIMM) training errors have occurred on memory riser arg1 . Arguments arg1 = riser letter Detailed Description A Load-Reduced DIMM (LR-DIMM) buffer initialization failure was detected during memory initialization. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0187 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Clock Detection phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0189 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Transmit DQS DCC phase.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0191 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 .
Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Clock Alignment phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system. For more information, see the platform Owners Manual.
UEFI0194 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Fine Command Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0196 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Error Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0198 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Read Level Fine Training phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module identified in the message.
UEFI0201 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Write Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0203 Message A failing memory buffer has been detected during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description A failing memory buffer has been identified on the memory riser identified in the message. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0205 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Command Clock Training - Group 0 phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0208 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Command Clock Training - Group All phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0210 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Receive Buffer Vref Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0212 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Early Command Training phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0215 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Basic Write Level Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0217 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Basic Write DQ/DQS Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0219 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Read Timing Centering 2D Training phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0222 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Round Trip Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0224 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Transmit Buffer Per Bit Deskew Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0226 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the DDR4 LR-DIMM Transmit Buffer Training phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0229 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Memory Buffer Receive Enable Training - Calibration phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0231 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Memory Buffer Write Leveling Training - Configuration Read phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0233 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Memory Buffer Write Leveling Training - FIFO Reset phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0236 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Write DQ/DQS Training - FIFO Reset phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0238 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Write DQ/DQS Training - Calibration phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0240 Message An error occurred during Voltage Regulator (VR) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Memory Voltage Regulator initialization during the VR0 SVID Ramp phase.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0242 Message Unable to enable the requested Partial Mirror size of arg1 GB due to the current DIMM population or hardware configuration does not support the requested size. arg2 GB was allocated instead.
Arguments arg1 = riser letter Detailed Description The Scalable Memory Interconnect (SMI) channel identified in the message is operating at a degraded width. This allows continued uptime although indicates an error condition requiring further investigation. This maybe an early indication of upcoming memory riser failure. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system.
UEFI0245 Message Quick Path Interconnect (QPI) link initialization error detected. Detailed Description Quick Path Interconnect (QPI) initialization failed to configure all installed processors to the maximum common frequency. Recommended Response Action Reseat all processors in the system and ensure all processors are matching. If the issue persists, contact your service provider.
UEFI0247 Message Quick Path Interconnect (QPI) initialization error detected. Detailed Description Quick Path Interconnect (QPI) initialization encountered a programmatic error. The requested Memory Mapped IO (MMIOH) size is not supported. MMIOH allocation was forced instead. Recommended Response Action Reseat all processors in the system and ensure all processors are matching. If the issue persists, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0249 Message Quick Path Interconnect (QPI) initialization error detected. Detailed Description Quick Path Interconnect (QPI) initialization encountered a programmatic error. A requested resource could not be allocated. Resource was forced to maximum possible value instead. Recommended Response Action Reseat all processors in the system and ensure all processors are matching.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0251 Message Memory riser arg1 is populated behind an empty processor socket. Arguments arg1 = riser number Detailed Description A memory riser was detected behind an empty processor socket. Memory must be installed behind a populated processor socket in order to be recognized by the system and available for usage. Check to make sure processors and memory are installed in a supported configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0253 Message Unable to enable NUMA Fault Resilient Memory (FRM) feature due to the current configuration does not support it. Detailed Description Unable to enable NUMA Fault Resilient Memory (FRM) feature due to the current configuration does not support it.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0255 Message Network Daughter Card 1 and Network Daughter Card 2 in the system do not match. Detailed Description Network Daughter Card 1 and Network Daughter Card 2 in the system do not match. Recommended Response Action Check the Network Daughter Cards and make sure they are the same type.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0257 Message Unable to boot to Service Partition because the target Service Partition was not found in the boot list. Detailed Description Cannot boot to Service Partition because the target Service Partition was not found in the boot list.
Category Configuration (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0263 Message Unable to perform iSCSI boot on connection arg1 because the network cable is not connected.
UEFI0265 Message Unable to perform iSCSI boot on connection arg1 because the iSCSI initiator IPv4 address is invalid. Arguments arg1 = number Detailed Description Unable to perform iSCSI boot on the connection identified in the message because the iSCSI initiator IPv4 address is invalid. Recommended Response Action Go to System Setup > Network Settings > iSCSI Device Settings page, make sure there is no typographical error in the Initiator IP address field, and retry the operation.
Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) No alerts are applicable for this message UEFI0268 Message Unable to perform iSCSI boot on connection arg1 because the iSCSI target name is invalid. Arguments arg1 = number Detailed Description Unable to perform iSCSI boot on the connection identified in the message because the iSCSI target name is invalid.
Detailed Description Unable to perform iSCSI boot on the connection identified in the message because the network connection to DHCPv4 server is not established. Recommended Response Action Check the network cable connection of the initiator or the DHCPv4 server and retry the operation.
UEFI0273 Message Unable to perform iSCSI boot on connection arg1 because the iSCSI target configuration data obtained from DHCPv4 server is invalid. Arguments arg1 = number Detailed Description Unable to perform iSCSI boot on the connection identified in the message because the iSCSI target configuration data obtained from DHCPv4 server is invalid. Recommended Response Action Do one of the following: 1) Reconfigure the DHCPv4 server root path option, and note that server name must be specified.
Recommended Response Action Do the following: 1) Make sure the iSCSI target system is online with the firewall configured to allow TCP access. 2) Make sure the server network infrastructure is configured to allow access to the iSCSI target. 3) Go to System Setup > Network Settings > iSCSI Device Settings > Connection Settings page, make sure the iSCSI initiator settings (iSCSI, DHCP, VLAN, initiator/target IP addresses) are configured correctly. 4) Retry the operation.
66 USR Event Messages USR0001 Message arg1 Arguments arg1 = message Detailed Description No detailed description is required. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0005 Message Login failed from arg1 : arg2 Arguments arg1 = username, arg2 = ip_address Detailed Description Login failed from UserID: IP Address Recommended Response Action Contact the iDRAC administrator and ensure the username and password credentials used are correct.
Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing ✔ CMC LC Log iDRAC Reset Chassis Event Proxy ✔* CMC USR0008 Message The Default Login Warning feature is disabled. Detailed Description The Default Login Warning feature is disabled. No warning is provided if any local user is configured with default credentials, Recommended Response Action No response action is required.
No alerts are applicable for this message USR0014 Message The current user session is invalid. Detailed Description The user session which is currently in use is invalid. Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) No alerts are applicable for this message USR0015 Message The specified user does not exist. Detailed Description The specified user does not exist.
Detailed Description There are no active sessions on the iDRAC for the specified user. Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) No alerts are applicable for this message USR0018 Message No active sessions currently exist. Detailed Description There are no active sessions on the iDRAC which can be displayed. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) No alerts are applicable for this message USR0021 Message Unable to close session with the specified ID Detailed Description The session could not be closed. A possible reason is that the session does not exist. Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 1 (Critical) No alerts are applicable for this message USR0022 Message The specified user already exists.
USR0030 Message Successfully logged in using arg1 , from arg2 and arg3 . Arguments arg1 = username, arg2 = IP address, arg3 = interface name Detailed Description Successful login for the username, IP address, and interface identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0032 Message The session for arg1 from arg2 using arg3 is logged off. Arguments arg1 = username, arg2 = IP address, arg3 = interface name Detailed Description The session for the username, IP address, and interface identified in the message is logged off. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0034 Message Login attempt alert for arg1 from arg2 using arg3 , IP will be blocked for arg4 seconds.
Detailed Description The VNC client is connected from the IP address identified in the message to the iDRAC VNC Server. Recommended Response Action No response action is required.
USR0152 Message Unable to connect the remote VNC session, because an incorrect VNC password was entered from the IP arg1 . Arguments arg1 = IP address Detailed Description Could not successfully connect to the remote VNC session, because an incorrect VNC password was entered from the IP address identified in the message. Recommended Response Action Enter the correct VNC password and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0170 Message The Front Panel USB port is attached to iDRAC Disk.USBFront. arg1 . Device details: Device class arg2 , Vendor ID arg3 , Manufacturer Name arg4 , Product ID arg5 , Product Name arg6 , Serial Number arg7 .
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0172 Message The Front Panel USB Management Port Mode setting is changed from arg1 to arg2 . Arguments arg1 = previous mode, arg2 = new mode Detailed Description The Front Panel USB Management Port Mode setting is changed as identified in the message.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0174 Message The Front Panel USB device is removed from the operating system. Detailed Description The Front Panel USB device is removed from the operating system. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 8490 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC USR0176 Message The Front Panel USB Port Over Current condition is cleared for the attached device Disk.USBFront. arg1 .
Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0180 Message The Quick Sync feature is enabled because the activate button on the bezel was pressed.
Detailed Description The Quick Sync feature is deactivated because the inactivity timeout limit was reached. Recommended Response Action Press the activate button on the bezel to activate the iDRAC Quick Sync feature.
Detailed Description A bezel with the iDRAC Quick Sync feature is detected. Recommended Response Action No response action is required.
Arguments arg1 = sensor type Detailed Description The peak value of the sensor identified in the message is reset. Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR100 Message The command was successful.
USR102 Message Invalid parameter value for arg1 . Arguments arg1 = parameter name Detailed Description The value provided for the specified parameter is invalid. Recommended Response Action To provide the correct value for the specified parameter, see Lifecycle ControllerRemote Services documentation. Category Configuration (USR = User Tracking) Severity Severity 2 (Warning) No alerts are applicable for this message USR103 Message Missing parameters arg1 .
USR105 Message The account is not configured. Detailed Description The user account used as credentials to access iDRAC is not enabled or configured to perform the operation. Recommended Response Action Retry the operation after creating the user account. Category Configuration (USR = User Tracking) Severity Severity 2 (Warning) No alerts are applicable for this message USR106 Message arg1 unauthorized for arg2 on arg3 .
USR8500 Message Excessive login failures from arg1 ; blocked for arg2 seconds. Arguments arg1 = IP address, arg2 = number Detailed Description Multiple login attempts were unsuccessful from the identified IP address. After detecting this error condition, this IP address will be blocked from login for the duration specified in the message.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* USR8502 Message Successfully closed Session: pid= arg1 sid= arg2 Arguments arg1 = process ID, arg2 = session ID Detailed Description The operation to close a user session using the session ID identified in the message was successful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔ CMC ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* USR8504 Message The IP address specified is out of range. Detailed Description The IP range filter feature is enabled in CMC. The IP address from where the login attempt was made is not in the specified range of IP address that can access the CMC.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔ CMC ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* USR8506 Message Successfully closed Session: sid= arg1 Arguments arg1 = session ID Detailed Description The operation to invalidate the Session identified in the message was successful. Recommended Response Action No response action is required.
Category Audit (USR = User Tracking) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔ CMC ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* USR8508 Message arg1 login was not successful (username= arg2 , ip= arg3 , reason= arg4 ) Arguments arg1 = Session type, arg2 = user name, arg3 = ip address, arg4 = failure reason Detailed Description The login attempt with
Recommended Response Action Contact the administrator and ensure the username and password credentials used are correct. Retry the operation with valid credentials.
Detailed Description Successful login from IP address by Username identified in the message. Recommended Response Action No response action is required.
Arguments arg1 = username, arg2 = IP address, arg3 = session type Detailed Description Successful login from IP address identified in the message by username identified in the message. Recommended Response Action No response action is required.
67 VDR Event Messages VDR1 Message arg1 failed. Arguments arg1 = VD Name Detailed Description A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency. Recommended Response Action Replace the failed component. You can identify which component has failed by locating the component that has a red "X" for its status.
Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2059 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ VDR100 Message arg1 is unavailable because of incompatibilities with the current controller.
VDR101 Message Virtual Adapter mapping reported for arg1 . Virtual Adapter 1 is now arg2 . Virtual Adapter 2 is now arg3 . Virtual Adapter 3 is now arg4 . Virtual Adapter 4 is now arg5 Arguments arg1 = Virtual Disk Name, arg2 = Access Policy 1, arg3 = Access Policy 2, arg4 = Access Policy 3, arg5 = Access Policy 4 Detailed Description Indicates the Virtual Disk to Virtual Adapter Mapping for audit purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR103 Message Hot Spare Protection policy deviation with severity set at Critical level occurred for arg1 .
Detailed Description The secure virtual disk operation was successful on the security capable virtual disk identified in the message. A security capable virtual disk is created using only SelfEncrypting Drives (SED). Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR106 Message arg1 on spun down power save mode drives is not available. Arguments arg1 = virtual disk name Detailed Description This alert is generated after successfully configuring a virtual disk on at least one spundown drive. The virtual disk creation is not yet complete on the remaining spundown drives because the drives are still spinning up. Recommended Response Action No response action is required.
OMSA Event ID 2412 OMSA Trap ID 120100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR108 Message Successfully created Controller Enhanced cache ( arg1 ). Arguments arg1 = virtual disk name Detailed Description The Controller Enhanced cache identified in the message was successfully created.
Detailed Description The Controller Enhanced cache identified in the message was successfully deleted. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ VDR110 Message Unrecoverable storage medium error detected on arg1 . Arguments arg1 = virtual disk name Detailed Description This alert is generated when an unrecoverable storage medium error is detected on the virtual disk. This error can be a prelude to the physical disk becoming nonfunctional.
OMSA Event ID 2418 OMSA Trap ID 120100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR112 Message Deleted the arg1 . Arguments arg1 = virtual disk Detailed Description The controller removed a virtual disk because of a delete virtual disk operation or a reset configuration operation. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2063 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ VDR13 Message arg1 rebuild has started.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* VDR14 Message The consistency check on arg1 was cancelled. Arguments arg1 = virtual disk Detailed Description A user cancelled the consistency check operation for a virtual disk. Recommended Response Action No response action is required.
Trap/EventID 4355 OMSA Event ID 2070 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR16 Message Consistency check of arg1 failed. Arguments arg1 = virtual disk Detailed Description A physical disk included in the virtual disk failed or there is an error in the parity information.
VDR17 Message arg1 format failed. Arguments arg1 = VD Name Detailed Description A physical disk included in the virtual disk failed. Recommended Response Action Replace the failed physical disk. Identify the failed physical disk by locating the disk that has a red "X" for its status. Rebuild the physical disk. When finished, restart the virtual disk format operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR19 Message Reconfiguration of arg1 has failed. Arguments arg1 = virtual disk Detailed Description The reconfiguration operation was not completed. This may be due to a user action or a physical disk failure.
Recommended Response Action No response action is required. Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR20 Message arg1 rebuild failed.
VDR21 Message Consistency check for arg1 has completed. Arguments arg1 = virtual disk Detailed Description This message is generated after a consistency check completes on a virtual disk. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR23 Message Initialization of arg1 has completed. Arguments arg1 = virtual disk Detailed Description This message is generated after initialization completes on a virtual disk. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2090 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR25 Message arg1 rebuild is completed.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* VDR26 Message The check consistency on a arg1 has been paused (suspended). Arguments arg1 = VD Name Detailed Description You paused the Check Consistency operation on a virtual disk. Recommended Response Action To resume the Check Consistency operation, right-click the virtual disk in the Storage Management tree view and select Resume Check Consistency.
Trap/EventID 4355 OMSA Event ID 2115 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR28 Message A virtual disk and its mirror have been split. Detailed Description A user has caused a mirrored virtual disk to be split.
VDR29 Message A mirrored virtual disk has been un-mirrored. Detailed Description A mirrored virtual disk is un-mirrored. When a virtual disk is mirrored, its data is copied to another virtual disk to maintain redundancy. After being un-mirrored, the disk formerly used as the mirror returns to being a physical disk and becomes available for inclusion in another virtual disk. Recommended Response Action This alert is provided for informational purposes.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR30 Message arg1 write policy has changed. Arguments arg1 = virtual disk Detailed Description A user changed the write policy for a virtual disk. Recommended Response Action This alert is provided for informational purposes.
Recommended Response Action Try importing foreign disks, if any. Check if the enclosure containing the Virtual Disk is disconnected from the controller. Insert any disks that are reported missing or failed. If the enclosure or disks were removed intentionally, the preserved cache can be discarded. See storage hardware documentation for more information on performing these steps.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* VDR33 Message Background initialization was cancelled for arg1 . Arguments arg1 = virtual disk Detailed Description Background initialization of a virtual disk was cancelled. This may be due to user action. This operation may automatically restart. Recommended Response Action No response action is required.
Trap/EventID 4353 OMSA Event ID 2129 OMSA Trap ID 120400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR35 Message Background initialization has completed for arg1 . Arguments arg1 = virtual disk Detailed Description Background initialization of a virtual disk completed.
VDR36 Message arg1 initialization is in-progress arg2 . Arguments arg1 = VD Name, arg2 = progresspercent Detailed Description Virtual disk initialization is in-progress. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR38 Message arg1 is renamed. Arguments arg1 = VD Name Detailed Description A user renamed a virtual disk. This alert is provided for informational purposes. Recommended Response Action No response action is required.
remapped the disk block to restore data consistency. This alert is provided for informational purposes. Recommended Response Action No response action is required. As a precaution, monitor the Log for other errors related to this virtual disk. If problems persist, contact technical support.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* VDR40 Message The reconfiguration of arg1 has resumed. Arguments arg1 = virtual disk Detailed Description This message is generated after the reconfiguration of a virtual disk resumes. Recommended Response Action No response action is required.
Trap/EventID 4355 OMSA Event ID 2194 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR42 Message Dedicated hot spare assigned physical disk arg1 . Arguments arg1 = args Detailed Description This alert is provided for informational purposes.
VDR43 Message Dedicated hot spare unassigned physical disk arg1 . Arguments arg1 = args Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR45 Message arg1 blink has been initiated. Arguments arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2245 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR47 Message A disk media error was corrected on arg1 .
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* VDR48 Message arg1 has inconsistent data. Arguments arg1 = VD Name Detailed Description This alert is provided for informational purposes. The virtual disk has inconsistent data. This may be caused when a power loss or system shutdown occurs while data is being written to the virtual disk. Recommended Response Action No response action is required.
Category Storage (VDR = Virtual Disk) Severity Severity 1 (Critical) Trap/EventID 4353 OMSA Event ID 2310 OMSA Trap ID 120400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR5 Message arg1 was deleted. Arguments arg1 = virtual disk Detailed Description The controller removed a virtual disk.
VDR50 Message Background Initialization (BGI) completed with uncorrectable errors on arg1 . Arguments arg1 = virtual disk Detailed Description The background initialization task encountered errors that cannot be corrected. The virtual disk contains physical disks that have unusable disk space or disk errors that cannot be corrected. Recommended Response Action Review other messages to identify whether the physical disk that has errors.
OMSA Event ID 2341 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR52 Message The consistency check found inconsistent parity data on arg1 . Arguments arg1 = virtual disk Detailed Description The data on physical disk members of the virtual disk does not match. Redundancy may be lost.
VDR53 Message The consistency check logging of inconsistent parity data is disabled for arg1 . Arguments arg1 = virtual disk Detailed Description The consistency check can no longer report errors in the parity data. Recommended Response Action See the storage hardware documentation for more information on consistency check operation. Contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR55 Message arg1 initialization has failed. Arguments arg1 = VD Name Detailed Description The controller cannot communicate with attached devices. A disk may be removed or contain errors. Cables may also be loose or defective.
Detailed Description This message occurs when a physical disk in the disk group was removed or when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt. Typically, the virtual disk (E.g. RAID 6) has multiple redundant disks and there is a problem with one of them. Recommended Response Action Replace the missing or failed physical disk.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* VDR58 Message Bad block medium error is detected at block arg1 on arg2 . Arguments arg1 = args, arg2 = VD Name Detailed Description Virtual disk bad blocks are due to presence of unrecoverable bad blocks on one or more member physical disks. Recommended Response Action Recovering a physical disk bad block depends on the RAID level and state of the virtual disk.
Severity Severity 3 (Informational) Trap/EventID 4355 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR6 Message arg1 configuration has changed. Arguments arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Arguments arg1 = initialization type, arg2 = virtual disk Detailed Description There are two modes of virtual disk initialization, full and fast. This initialization type identified in the message is running on the virtual disk identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* VDR8 Message arg1 has become degraded. Arguments arg1 = virtual disk Detailed Description This message occurs when a physical disk in the disk group was removed or when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt.
Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2058 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR91 Message Consistency check for arg1 has detected multiple uncorrectable medium errors.
VDR92 Message Consistency check for arg1 has completed with uncorrectable errors. Arguments arg1 = virtual disk Detailed Description This message occurs if there are medium errors in the physical drives. Recommended Response Action Replace the failed drives.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR94 Message Controller preserved cache was recovered for arg1 . Arguments arg1 = virtual disk Detailed Description This message occurs if the controller pinned cache is recovered. Recommended Response Action No response action is required.
Recommended Response Action Replace the disk in the Virtual disk, generating this alert and restore from backup. You may have lost data.
VDR97 Message Patrol Read corrected a media error on arg1 . Arguments arg1 = VD Name Detailed Description The Patrol Read task has encountered an error such as a bad disk block and remapped data to correct the error. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR99 Message arg1 is unavailable because of an ID conflict in the fault-tolerant pair. Arguments arg1 = virtual disk Detailed Description The virtual disk identified in the message cannot be used because of an ID conflict with another virtual disk.
VF Event Messages 68 VF001 Message Command successful. Detailed Description The command was successful Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF002 Message General failure Detailed Description The operation did not complete successfully because of an internal issue with the firmware.
No alerts are applicable for this message VF004 Message Invalid value for the parameter: arg1 Arguments arg1 = parameter name Detailed Description The value of the input parameter identified in the message is not a valid value. Recommended Response Action Refer the iDRAC and Lifecycle Controller User Guides for the required input parameters for this method.
VF0060 Message Unable to perform the requested operation. Make sure the SD card is inserted and enabled. Detailed Description The SD card was not detected. Therefore, the requested operation cannot be completed. Recommended Response Action Verify whether the SD card is inserted and enabled, then re-try.
Detailed Description The specified partition was formatted. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF010 Message Partition formatting did not complete successfully. Detailed Description Formatting the specified partition did not complete successfully.
Severity Severity 2 (Warning) No alerts are applicable for this message VF013 Message SD card locked Detailed Description The SD card is locked by another operation. Recommended Response Action Rerun the command after about 2 minutes Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF014 Message vFlash not disabled Detailed Description Enabling vFlash was not successful because the vFlash feature is not disabled.
VF016 Message SD card is read only Detailed Description The SD card is not writable. Recommended Response Action Check the write-protection tab of the SD card. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF017 Message SD card not initialized Detailed Description The SD card is not initialized. Recommended Response Action In order to perform this operation, first initialize the SD Card.
Detailed Description The SD card is full. Recommended Response Action Check all the partitions, delete the ones that are not necessary and try this operation again. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF020 Message Exceeded maximum number of partitions Detailed Description The number of partitions exceeded the maximum number allowed on a SD card.
Severity Severity 3 (Informational) No alerts are applicable for this message VF023 Message Partition label not unique Detailed Description Partition with this label exists. Duplicate labels are not supported. Recommended Response Action Try a different partition label. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF024 Message Partition locked Detailed Description The partition is locked by another operation.
VF026 Message Partition index in use Detailed Description This partition index has already been used. Recommended Response Action This partition index has already been used. Try a different index. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF027 Message Partition already attached Detailed Description This partition is attached and attempts to attach it will fail.
Detailed Description The user account credentials provided for this vFlash operation do not have the correct privileges. Virtual Media Access privilege is required to perform vFlash SD Card media operations. Recommended Response Action Use a different user account the has Virtual Media Access privilege.
Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF033 Message Invalid partition format type. Detailed Description The specified format type is not a valid type. Recommended Response Action Try a format type that is supported. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF034 Message Invalid partition access type.
VF036 Message Attach partition successful. Detailed Description The partition was attached. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF037 Message Attach partition operation did not complete successfully. Detailed Description The attaching partition operation did not complete successfully. Recommended Response Action No response action is required.
Detailed Description The detaching partition operation did not complete successfully. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF040 Message Image hash verification was not successful. Detailed Description The downloaded image did not successfully complete the hash verification. Recommended Response Action Try the download again.
Severity Severity 2 (Warning) No alerts are applicable for this message VF043 Message Remote file too large. Detailed Description The file size is too large to be used. Recommended Response Action Try a smaller file. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF044 Message TFTP download operation was not successful. Detailed Description File transfer was not successful.
VF046 Message HTTP download operation was not successful. Detailed Description File transfer was not successful. This could be because of network problems or an operational problem with the file server. Recommended Response Action Try the download again. If the issue persists, validate that the network share is operational. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF047 Message Unsupported SD Card.
Detailed Description The initializing SD card operation did not complete successfully. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF050 Message Export partition successful. Detailed Description The partition was copied. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) No alerts are applicable for this message 2223
VFL Event Messages 69 VFL0001 Message The vFlash SD Card operation is successful. Detailed Description The requested operation for the vFlash SD Card completed successfully. Recommended Response Action No response action is required. Category Configuration (VFL = vFlash Event) Severity Severity 3 (Informational) No alerts are applicable for this message VFL0002 Message Unable to query the vFlash media status.
No alerts are applicable for this message VFL0004 Message Unable to perform the vFlash media operation. Detailed Description The requested vFlash media operation could not be performed, because some of the iDRAC services are busy. Recommended Response Action Retry the operation. If the issue persists, restart the iDRAC and retry the operation. If the issue continues to persist, contact your service provider.
Detailed Description Unable to access the vFlash media, because another operation is currently using the vFlash media. Recommended Response Action Wait until the vFlash media is available for the requested operation, and then retry the operation. Category System Health (VFL = vFlash Event) Severity Severity 2 (Warning) No alerts are applicable for this message VFL0010 Message An operation is in progress on the SD card.
Severity Severity 3 (Informational) No alerts are applicable for this message VFL0013 Message The vFlash SD Card is in read-only mode. Detailed Description The request could not be successfully completed, because the vFlash SD Card is in read-only mode. Write operations cannot be performed on the card. Recommended Response Action Change the access mode on the vFlash SD Card to read-write.
VFL0016 Message vFlash media partition is already in attached state. Detailed Description The requested vFlash media partition is already attached to the host operating system. Recommended Response Action No response action is required. Category Configuration (VFL = vFlash Event) Severity Severity 3 (Informational) No alerts are applicable for this message VFL0017 Message Unable to perform the vFlash media operation because the vFlash media partition is corrupted.
Detailed Description The requested vFlash media partition is already detached from the host operating system. Recommended Response Action No response action is required. Category System Health (VFL = vFlash Event) Severity Severity 3 (Informational) No alerts are applicable for this message VFL0020 Message vFlash SD card is not ready. Detailed Description The vFlash SD card is currently in use by another operation.
Category Configuration (VFL = vFlash Event) Severity Severity 3 (Informational) No alerts are applicable for this message VFL0704 Message SD card is not present and could not be initialized. Detailed Description None Recommended Response Action Insert the SD card and try again. Category Configuration (VFL = vFlash Event) Severity Severity 1 (Critical) No alerts are applicable for this message VFL0705 Message Error occurred and SD card could not be initialized.
VFL0710 Message vFlash is not enabled; the SD card could not be initialized. Detailed Description none Recommended Response Action Enable vFlash and try again. Category Configuration (VFL = vFlash Event) Severity Severity 1 (Critical) No alerts are applicable for this message VFL0711 Message SD card is write-protected and could not be initialized. Detailed Description An error occurred while initializing the SD card because the SD card writeprotection feature is enabled.
Detailed Description none Recommended Response Action Detach the partitions and try again. Category Configuration (VFL = vFlash Event) Severity Severity 1 (Critical) No alerts are applicable for this message VFL0714 Message SD card is not ready and could not be initialized. Detailed Description none Recommended Response Action Retry after a few minutes.
Severity Severity 1 (Critical) No alerts are applicable for this message VFL0719 Message One or more partitions are in use; the SD card could not be initialized. Detailed Description The SD card is in use by another process. Initialization requires exclusive access to the SD card to complete the initialization. Recommended Response Action The SD card is in use by another process. Retry after a few minutes.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC VFL1002 Message Removable Flash Media arg1 is IPMI-function ready. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1004 Message Removable Flash Media arg1 is ready. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Category System Health (VFL = vFlash Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1006 Message Removable Flash Media arg1 is offline.
Recommended Response Action No response action is required. Category System Health (VFL = vFlash Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1008 Message Failure detected on Removable Flash Media arg1 . Arguments arg1 = name Detailed Description An error is reported during a SD card read or write.
VFL1009 Message Removable Flash Media arg1 is operating normally. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VFL1011 Message Removable Flash Media arg1 was deactivated. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1013 Message Removable Flash Media arg1 has finished booting. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 2506 LCD Message Removable Flash Media is write protected. Check SD Card iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VFL1015 Message Removable Flash Media arg1 is writable.
Detailed Description The SD card is not detected or not installed. Recommended Response Action If unintended, reinstall the flash media. Category System Health (VFL = vFlash Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1017 Message Media is present for Removable Flash Media arg1 .
70 VFLA Event Messages VFLA1000 Message Removable Flash Media arg1 is absent. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
71 VLT Event Messages VLT0100 Message Processor module arg1 voltage is less than the lower warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins.
Category System Health (VLT = Voltage) Severity Severity 1 (Critical) LCD Message Processor module voltage is outside of range. Contact support Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VLT0102 Message Processor module arg1 voltage is greater than the upper warning threshold.
Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0105 Message Processor module arg1 voltage is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action 1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* VLT0202 Message The system board arg1 voltage is greater than the upper warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Category System Health (VLT = Voltage) Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message The system board voltage is outside of range. Contact support Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* VLT0204 Message The system board arg1 voltage is outside of range.
VLT0205 Message The system board arg1 voltage is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0207 Message The memory module arg1 arg2 voltage is less than the lower critical threshold. Arguments arg1 = number, arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0210 Message The memory module arg1 arg2 voltage is outside of range. Arguments arg1 = number, arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module.
Trap/EventID iDRAC 2171 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC VLT0212 Message The disk drive bay arg1 voltage is less than the lower warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0215 Message The disk drive bay arg1 voltage is greater than the upper critical threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions.
Category System Health (VLT = Voltage) Severity Severity 1 (Critical) Trap/EventID 2169 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0217 Message The disk drive bay arg1 voltage is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* VLT0220 Message The arg1 voltage is greater than the upper warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Category System Health (VLT = Voltage) Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message The voltage is outside of range. Contact support Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* VLT0222 Message The arg1 voltage is outside of range.
VLT0223 Message The arg1 voltage is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0225 Message The memory module arg1 voltage is less than the lower critical threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0228 Message The memory module arg1 voltage is outside of range. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module.
Trap/EventID iDRAC 2171 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC VLT0230 Message The mezzanine card arg1 arg2 voltage is less than the lower warning threshold. Arguments arg1 = number, arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0233 Message The mezzanine card arg1 arg2 voltage is greater than the upper critical threshold. Arguments arg1 = number, arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions.
Severity Severity 1 (Critical) Trap/EventID 2169 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0235 Message The mezzanine card arg1 arg2 voltage is within range. Arguments arg1 = number, arg2 = name Detailed Description None Recommended Response Action No response action is required.
Detailed Description Low voltages may be the result of a problem with the voltage regulator or a problem with the processor. The low voltage may cause the processor to fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0302 Message CPU arg1 arg2 voltage is greater than the upper warning threshold. Arguments arg1 = number, arg2 = name Detailed Description High voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may result in damage to the processor or other electronic components inside the system.
Category System Health (VLT = Voltage) Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message CPU voltage is outside of range. Reseat CPU iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0304 Message CPU arg1 arg2 voltage is outside of range.
VLT0305 Message CPU arg1 arg2 voltage is within range. Arguments arg1 = number, arg2 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VLT401 Message Unable to read arg1 sensor value. Arguments arg1 = sensor name Detailed Description A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the monitoring capability of the system.
Arguments arg1 = sensor name, arg2 = voltage Detailed Description The voltage sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VLT404 Message The arg1 sensor detected an error with a value of arg2 Volts. Arguments arg1 = sensor name, arg2 = voltage Detailed Description The voltage sensor identified in the message is faulty, or the voltage exceeds the preset critical threshold.
VLT405 Message The arg1 sensor has failed with a value of arg2 Volts. Arguments arg1 = sensor name, arg2 = voltage Detailed Description A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the monitoring capability of the system. Recommended Response Action Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults.
72 VME Event Messages VME0001 Message Virtual Console session started. Detailed Description Virtual Console session started. Recommended Response Action No response action is required. Category Audit (VME = Virtual Media) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VME0002 Message Virtual Media session started.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VME0003 Message Virtual Console session fails to start. Detailed Description Virtual Console session fails to start. Recommended Response Action Retry the Virtual Console session initiation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VME0005 Message Virtual Console session exited. Detailed Description Virtual Console session exited. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VME0007 Message Virtual Console session created. Detailed Description Virtual Console session created. Recommended Response Action No response action is required.
LC Log iDRAC CMC 2282 ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
VRM Event Messages 73 VRM0009 Message No Virtual Media devices are currently connected. Detailed Description No virtual media was found to disconnect. Recommended Response Action No response action is required. Category System Health (VRM = Virtual Console) Severity Severity 1 (Critical) No alerts are applicable for this message VRM0010 Message Unable to disconnect Virtual Media devices. Detailed Description The virtual media could not be disconnected.
VRM0012 Message The Virtual Media image server is already connected. Detailed Description The Virtual Media server is already connected. Recommended Response Action No response action is required. Category System Health (VRM = Virtual Console) Severity Severity 3 (Informational) No alerts are applicable for this message VRM0013 Message Virtual Media services is currently attached to the USB interface. It must be detached before the image server can be connected.
Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (VRM = Virtual Console) Severity Severity 3 (Informational) No alerts are applicable for this message VRM0016 Message Virtual Console is DISABLED Detailed Description Success message. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) No alerts are applicable for this message VRM0019 Message Remote Image is now Configured Detailed Description The Remote Image is now configured and ready to use. Recommended Response Action No response action is required. Category System Health (VRM = Virtual Console) Severity Severity 3 (Informational) No alerts are applicable for this message VRM0020 Message Unable to determine current Remote Image state.