Reference Guide
Cause and Action Cause: A device that was previously in an error state has returned to a normal state.
For example, if an enclosure became too hot and subsequently cooled down, you
may receive this alert. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2121 is a clear alert for alert 2048.
Related Alert Number: 2050, 2065, 2158
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
752,802, 852, 902, 952, 1002,1052, 1102, 1152, 1202
Event ID — 2122
Description Redundancy degraded.
Severity Warning / Non-critical
Cause and Action Cause: One or more of the enclosure components has failed.
For example, a fan or power supply may have failed. Although the enclosure is
currently operational, the failure of additional components could cause the
enclosure to fail.
Action: Identify and replace the failed component. To identify the failed
component, select the enclosure in the tree view and click the Health subtab. Any
failed component is identified with a red X on the enclosure’s Health subtab.
Alternatively, you can select the Storage object and click the Health subtab.
The controller status displayed on the Health subtab indicates whether a controller
has a Failed or Degraded component.
See the enclosure documentation for information on replacing enclosure
components and for other diagnostic information.
Related Alert
Information
Clear Alert Number: 2124
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
1305
Event ID — 2123
Description Redundancy lost.
Severity Warning / Non-critical
86