Reference Guide

rebuild does not start automatically after you have inserted a suitable physical disk,
then run the Rebuild task. See the Server Administrator Storage Management User’s
Guide for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2326
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2306
Description Bad block table is 80% full.
Severity Warning / Non-critical
Cause and Action Cause: The bad block table is used for remapping bad disk blocks. This table fills, as
bad disk blocks are remapped. When the table is full, bad disk blocks can no longer
be remapped, and disk errors can no longer be corrected. At this point, data loss
can occur. The bad block table is now 80% full.
Action: Back up your data. Replace the disk generating this alert and restore from
back up.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2307
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2307
Description Bad block table is full. Unable to log block %1.
Severity Critical / Failure / Error
Cause and Action Cause: The bad block table is used for remapping bad disk blocks. This table fills, as
bad disk blocks are remapped. When the table is full, bad disk blocks can no longer
be remapped and disk errors can no longer be corrected. At this point, data loss
can occur. The %1 indicates a substitution variable. The text for this substitution
variable is displayed with the alert in the alert log and can vary depending on the
situation.
Action: Replace the disk generating this alert. If necessary, restore your data from
backup.
155