Reference Guide
SNMP Trap
Numbers
854
Event ID — 2303
Description The enclosure cannot support both SAS and SATA physical disks. Physical disks
may be disabled.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2304
Description An attempt to hot plug an EMM has been detected. This type of hot plug is not
supported.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2211
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2305
Description The physical disk is too small to be used for a rebuild.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk is too small to rebuild the data.
Action: Remove the physical disk and insert a new physical disk that is the same
size or larger than the disk that is being rebuilt. The new physical disk must also use
the same technology (for example, SAS or SATA) as the disk being rebuilt. If the
154