Reference Guide

Event ID — 2162
Description Communication regained.
Severity OK / Normal / Informational
Cause and Action Cause: Communication with an enclosure has been restored. This alert is for
informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2162 is a clear alert for alerts 2137 and 2292.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2163
Description Rebuild completed with errors.
Severity OK / Normal / Informational
Cause and Action Cause: During a rebuild one or more blocks of data was not recoverable due to
missing parity information. Some data loss may have occurred.
Action: Perform a check to verify the built array. Any files that are impacted should
be restored from a backup. See the Storage Management online help for more
information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2164
Description See the Readme file for a list of validated controller driver versions.
Severity OK / Normal / Informational
Cause and Action Cause: Storage Management is unable to determine whether the system has the
minimum required versions of the RAID controller drivers. This alert is for
informational purposes.
102