Reference Guide

Detailed
Description
Physical disk inserted is of the incorrect protocol. SAS or SATA mixing is not
supported in the same virtual disk.
Recommended
Response
Action
Remove drive, insert correct protocol type, and force a rebuild as imposed for
controller and system.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2367
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR7
Message arg1 has degraded.
Arguments arg1 = physical disk
Detailed
Description
A physical disk has reported an error condition and may be degraded. The physical
disk may have reported the error condition in response to a check consistency or
other operation.
Recommended
Response
Action
Replace the degraded physical disk. Identify the disk that is degraded by locating
the disk that has a red "X" for its status. Perform a rescan after replacing the disk.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2051
OMSA Trap ID 90300
980