Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR60
Message Error occurred on arg1 : arg2 .
Arguments arg1 = physical disk, arg2 = error code
Detailed
Description
The reason for the error can vary depending on the situation. The firmware error
code is indicated in the message.
Recommended
Response
Action
Verify the health of attached devices. Review the Lifecycle log for significant
events. Replace faulty hardware, if required. Make sure the cables are attached
securely. Refer to the storage hardware documentation for more information on
checking the cable connections.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2346
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR61
Message The rebuild of arg1 failed due to errors on the source physical disk.
Arguments arg1 = physical disk
Detailed
Description
It is not possible to rebuild data that resides on a defective disk.
Recommended
Response
Action
Replace the source disk and restore data from backup.
974