Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR44
Message The clear operation on arg1 failed.
Arguments arg1 = physical disk
Detailed
Description
A Clear task was being performed on a physical disk but the task was interrupted
and did not complete successfully. The controller may have lost communication
with the disk, the disk was removed, or the cables may be loose or defective.
Recommended
Response
Action
Verify that the disk is present and not in a Failed state. Make sure the cables are
attached securely. See the storage hardware documentation for more information
on checking the cables. Restart the Clear task.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
OMSA Event ID 2270
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR46
Message Patrol Read found an uncorrectable media error on arg1 .
Arguments arg1 = physical disk
Detailed
Description
The Patrol Read task has encountered an error that cannot be corrected. There
may be a bad disk block that cannot be remapped.
Recommended
Response
Action
Backup your data from the disk. Start disk initialization and wait for it to complete,
then restore the data from the backup to the disk.
963