Reference Guide
Recommended
Response
Action
Add a SAS disk that is large enough to be used as the hot spare and assign the new
disk as a hot spare.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2206
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔ ✔*
PDR36
Message The only hot spare available is a SAS disk arg1 .
Arguments arg1 = PD Name
Detailed
Description
The only physical disk available to be assigned as a hot spare is using SAS
technology. The physical disks in the virtual disk are using SATA technology.
Because of this difference in technology, the hot spare cannot rebuild data if one
of the physical disks in the virtual disk fails.
Recommended
Response
Action
Add a SATA disk that is large enough to be used as the hot spare and assign the
new disk as a hot spare.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2207
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC ✔ ✔* ✔ ✔*
957