Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR29
Message Rebuild on arg1 completed with error(s).
Arguments arg1 = PD Name
Detailed
Description
See A Rebuild Completes with Errors for more information.
Recommended
Response
Action
See A Rebuild Completes with Errors for more information.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
OMSA Event ID 2163
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR3
Message arg1 is not functioning correctly.
Arguments arg1 = PD Name
Detailed
Description
The RAID Controller may not be able to read/write data to the physical disk drive
indicated in the message. This may be due to a failure with the physical disk drive
or because the physical disk drive was removed from the system.
Recommended
Response
Action
Remove and re-insert the physical disk drive identified in the message and make
sure the physical disk drive is inserted properly. If the issue persists, replace the
physical disk drive.
952