Reference Guide
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
OMSA Event ID 2160
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔ ✔*
PDR28
Message Dedicated hot spare unassigned from arg1 .
Arguments arg1 = PD Name
Detailed
Description
A physical disk that was assigned as a hot spare has been unassigned and is no
longer functioning as a hot spare. The physical disk was unassigned by a user or
automatically unassigned by Storage Management. Storage Management unassigns
hot spares that have been used to rebuild data. Once data is rebuilt onto the hot
spare, the hot spare becomes a member of the virtual disk and is no longer
assigned as a hot spare. Assign a new hot spare to maintain data protection in this
situation.
Recommended
Response
Action
Although this alert is provided for informational purposes, you may need to assign
a new hot spare to the virtual disk. Refer to product documentation and see the
section Protecting Your Virtual Disk with a Hot Spare for more information.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
OMSA Event ID 2161
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC ✔ ✔* ✔ ✔*
951