Reference Guide
PDR207
Message Unable to assign arg1 as a dedicated hot spare.
Arguments arg1 = physical disk name
Detailed
Description
Unable to assign the physical disk as a dedicated hot spare because the selected
disk size does not meet the size requirements of the target Virtual Disk.
Recommended
Response
Action
Select a physical disk that matches the size required for the disks used in the target
Virtual Disk, and retry the operation.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
OMSA Event ID 2386
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
PDR208
Message Instant Secure Erase operation successfully completed on arg1 .
Arguments arg1 = physical disk name
Detailed
Description
The secure erase operation successfully completed on the Self-Encrypting Drive
(SED) identified in the message.
Recommended
Response
Action
No response action is required.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
OMSA Event ID 2390
OMSA Trap ID 90100
941