Reference Guide
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
OMSA Event ID 2443
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PDR1116
Message Drive arg1 is removed.
Arguments arg1 = number
Detailed
Description
The controller detected a drive removal
Recommended
Response
Action
If unintended, verify drive installation. Remove and reseat the indicated disk. If the
problem persists, contact technical support. Refer to the product documentation
to choose a convenient contact method.
Category System Health (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 2297
LCD Message Drive <number> is removed. Check drive
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
926