Reference Guide
Trap/EventID 2299
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
PDR1101
Message Fault detected on drive arg1 .
Arguments arg1 = number
Detailed
Description
The controller detected a failure on the disk and has taken the disk offline.
Recommended
Response
Action
Remove and reseat the failed disk. If the problem persists, contact technical
support. Refer to the product documentation to choose a convenient contact
method.
Category System Health (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 2297
LCD Message Fault detected on drive <number>. Check drive.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
PDR1102
Message A predictive failure detected on drive arg1 .
Arguments arg1 = number
921