Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
PDR107
Message The physical disk drive arg1 is assigned as a global hot-spare.
Arguments arg1 = physical disk drive name
Detailed
Description
The physical disk drive identified in the message is assigned as a global hot-spare.
Recommended
Response
Action
No response action is required.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
PDR108
Message The physical disk drive arg1 is unassigned as a global hot spare.
Arguments arg1 = physical disk drive name
Detailed
Description
The physical disk identified in the message that had been assigned as a hot spare
has been unassigned and is no longer functioning as a hot spare. The physical disk
was unassigned by a user or automatically by the storage management software.
When one of the disks in a virtual disk fails, data is rebuilt onto the hot spare, The
hot spare becomes a member of the virtual disk and is no longer assigned as a hot
spare. In this situation, assigning a new hot spare to maintain data protection in
recommended.
918