Reference Guide
Detailed
Description
The controller detected that the drive was removed.
Recommended
Response
Action
Verify drive installation. Remove and reseat the failed drive. If the problem persists,
contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 2297
LCD Message Drive <number> removed from disk drive bay <bay>. Check drive.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
PDR1017
Message Drive arg1 in disk drive bay arg2 is operating normally.
Arguments arg1 = number, arg2 = bay
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 2299
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
910