Reference Guide
Recommended
Response
Action
Cycle input power, update component drivers, remove and re-install the device at
the next scheduled service time.
Category System Health (PCI = PCI Device)
Severity Severity 2 (Warning)
Trap/EventID 2418
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
PCI2000
Message A fatal IO error detected on a component at bus arg1 device arg2 function arg3 .
Arguments arg1 = bus, arg2 = device, arg3 = func
Detailed
Description
System performance may be degraded, or system may fail to operate.
Recommended
Response
Action
Cycle input power, update component drivers, remove and re-install the device.
Category System Health (PCI = PCI Device)
Severity Severity 1 (Critical)
Trap/EventID 2417
LCD Message Fatal IO error on bus <bus> device <device> function <func>. Contact support
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
881