Reference Guide

Arguments arg1 = bus, arg2 = device, arg3 = func
Detailed
Description
System performance may be degraded. The bus is not operating at maximum
speed or width.
Recommended
Response
Action
Cycle input power, update component drivers, if device is removable, re-install the
device.
Category System Health (PCI = PCI Device)
Severity Severity 2 (Warning)
Trap/EventID 2418
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PCI1342
Message A bus time-out was detected on a component at slot arg1 .
Arguments arg1 = number
Detailed
Description
System performance may be degraded. The device has failed to respond to a
transaction (master/target abort or completion timeout).
Recommended
Response
Action
Cycle input power, update component drivers, if device is removable, re-install the
device.
Category System Health (PCI = PCI Device)
Severity Severity 1 (Critical)
Trap/EventID 2417
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC