Reference Guide

Trap/EventID 2417
LCD Message Bus fatal error on bus <bus> device <device> function <func>. Power cycle system.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
PCI1321
Message A high-severity issue is detected in a component of the bus arg1 , device 0,
function arg2 .
Arguments arg1 = bus ID, arg2 = function ID
Detailed
Description
A high-severity issue is detected in the component identified in the message.
Recommended
Response
Action
Remove and reinsert the component identified in the message, and then monitor
the log for a re-occurrance of the issue. If the issue persists, and occurs during
server startup, update the component firmware. If the issue persists and occurs
during OS runtime, restart the server and update the OS drivers for the component
identified in the message.
Category System Health (PCI = PCI Device)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PCI1322
Message Bus performance degraded for a component at bus arg1 device arg2 function
arg3 .
874