Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
PCI1319
Message A high-severity issue is detected in the SSD bay arg1 , Slot arg2 .
Arguments arg1 = bay id, arg2 = slot id
Detailed
Description
A high-severity issue was detected in the SSD bay identified in the message.
Recommended
Response
Action
Remove and reinsert the component identified in the message, and then monitor
the log for a re-occurrance of the issue. If the issue persists, and occurs during
server startup, update the component firmware. If the issue persists and occurs
during OS runtime, restart the server and update the OS drivers for the component
identified in the message.
Category System Health (PCI = PCI Device)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PCI1320
Message A bus fatal error was detected on a component at bus arg1 device arg2 function
arg3 .
Arguments arg1 = bus, arg2 = device, arg3 = func
Detailed
Description
System performance may be degraded, or system may fail to operate.
Recommended
Response
Action
Cycle input power, update component drivers, if device is removable, re-install the
device.
Category System Health (PCI = PCI Device)
Severity Severity 1 (Critical)
873