OSD61
Message IP Address format is invalid.
Detailed
Description
The IP Address format is invalid and cannot be validated. The specified IP address
may not be a valid IPv4 or IPv6 address.
Recommended
Response
Action
Verify the IP address format and retry the operation.
Category Configuration (OSD = OS Deployment)
Severity Severity 2 (Warning)
No alerts are applicable for this message
OSD7
Message Unable to retrieve Lifecycle Controller handle.
Detailed
Description
Unable to connect to Lifecycle Controller because of an existing open connection
or an internal error.
Recommended
Response
Action
Reset iDRAC, and rerun the command to correct the problem.
Category Configuration (OSD = OS Deployment)
Severity Severity 1 (Critical)
No alerts are applicable for this message
OSD8
Message Setting Boot to PXE through IPMI failed.
Detailed
Description
The BIOS boot order set to PXE using a standard IPMI command has failed.
Recommended
Response
Action
1) Check BIOS PXE settings. 2) Rerun the command. 3) Reset iDRAC and rerun the
command.
Category Configuration (OSD = OS Deployment)
Severity Severity 1 (Critical)
No alerts are applicable for this message