Reference Guide

OSD45
Message Cannot delete ISO image from VFlash.
Detailed
Description
The ISO Image present in VFlash is attached to the host system. The ISO Image
cannot be deleted from VFlash.
Recommended
Response
Action
Execute DetachISOFromVFlash() before running DeleteISOFromVFlash()
Category Configuration (OSD = OS Deployment)
Severity Severity 2 (Warning)
No alerts are applicable for this message
OSD46
Message VFlash in use.
Detailed
Description
Another process (iDRAC GUI /racadm/iDRAC configuration utility) is currently
accessing VFlash.
Recommended
Response
Action
Wait until the access to VFlash is relinquished and then retry this command.
Category Configuration (OSD = OS Deployment)
Severity Severity 3 (Informational)
No alerts are applicable for this message
OSD47
Message Inaccessible network share.
Detailed
Description
Unable to access the network share using the credentials specified or the firewall
might be enabled and is preventing access to the share.
Recommended
Response
Action
Make sure that the firewall is disabled, and that the credentials (username,
password) are correct.
Category Configuration (OSD = OS Deployment)
Severity Severity 2 (Warning)
No alerts are applicable for this message
848