Reference Guide

Recommended
Response
Action
Reset iDRAC to detach this device automatically.
Category Configuration (OSD = OS Deployment)
Severity Severity 1 (Critical)
No alerts are applicable for this message
OSD26
Message Unable to continue with BootToPXE - another command is running.
Detailed
Description
Unable to continue with BootToPXE command because another process is using
Lifecycle Controller.
Recommended
Response
Action
See ConcreteJob status to make sure that the running process is complete, and
then run BootToPXE.
Category Configuration (OSD = OS Deployment)
Severity Severity 2 (Warning)
No alerts are applicable for this message
OSD27
Message Copying drivers for selected operating system failed.
Detailed
Description
Copying drivers for selected operating system failed. The Driver Pack may be
unusable.
Recommended
Response
Action
Update the Driver Pack using USC or DUP and then rerun the command.
Category Configuration (OSD = OS Deployment)
Severity Severity 3 (Informational)
No alerts are applicable for this message
OSD28
Message Hash verification on the ISO image failed.
Detailed
Description
Hash verification on the ISO image has failed. The hash value specified in the
command is either incorrect or the ISO image has been changed.
Recommended
Response
Action
1) Verify that the hash value specified in the command is correct. 2) Make sure that
the ISO has not been changed 3) Replace the ISO image on the share and rerun the
command.
841