Reference Guide

Recommended
Response
Action
1) Rerun the command. 2) Reset iDRAC
Category Configuration (OSD = OS Deployment)
Severity Severity 1 (Critical)
No alerts are applicable for this message
OSD23
Message Unable to continue with DetachISOImage - another command is in the process of
exposing the ISO Image and booting to it.
Detailed
Description
Cannot continue with DetachISOImage because another command is in the
process of exposing the ISO image and booting to it.
Recommended
Response
Action
See the ConcreteJob status to make sure that the current running process is
complete and then run DetachISOImage.
Category Configuration (OSD = OS Deployment)
Severity Severity 3 (Informational)
No alerts are applicable for this message
OSD24
Message Unable to continue with DetachDrivers - UnPackAndAttach is in progress.
Detailed
Description
Unable to continue with DetachDrivers - UnPackAndAttach is in progress.
Recommended
Response
Action
Wait until UnpackAndAttach finishes and then run DetachDrivers. This can take
more than 5 minutes.
Category Configuration (OSD = OS Deployment)
Severity Severity 3 (Informational)
No alerts are applicable for this message
OSD25
Message Unable to detach USB device containing operating system drivers.
Detailed
Description
Detaching the USB device (that contains drivers for the operating system
installation) from the host has failed. The device may be detached, or iDRAC may
not be operating normally.
840