Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
MEM9008
Message Intel DDR Memory interconnect arg1 has a non-recoverable issue.
Arguments arg1 = link number
Detailed
Description
A non-recoverable issue was detected in the propagation of signals on the Intel
DDR memory interconnect identified in the message.
Recommended
Response
Action
Reseat all DIMMs on the memory riser, reseat the memory riser, and restart the
server. If the issue persists, contact your service provider.
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message Intel DDR interconnect <number> has fatal error. Reseat mem riser.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
MEM9009
Message Intel DDR Memory interconnect arg1 has a correctable error.
Arguments arg1 = link number
Detailed
Description
A correctable error was detected in the propagation of signals on the Intel DDR
memory interconnect identified in the message.
Recommended
Response
Action
Do the following: 1) Reseat all DIMMs on the memory riser, 2) Reseat the memory
riser, and 3) Restart the server. If the issue persists, contact your service provider.
Category System Health (MEM = Memory)
Severity Severity 2 (Warning)
817