Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
MEM6004
Message Memory device status is critical. Memory device location: arg1 , Possible memory
module event cause: arg2 .
Arguments arg1 = location, arg2 = cause
Detailed
Description
The memory module may not be correctly seated, wrongly configured, or has
failed.
Recommended
Response
Action
Review the Embedded System Management (ESM) Log for memory exceptions. Re-
install the memory modules at the identified location .
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
OMSA Event ID 5404
OMSA Trap ID 5404
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔* ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
MEM6005
Message Memory device has failed. Memory device location: arg1 , Possible memory
module event cause: arg2 .
Arguments arg1 = location, arg2 = cause
Detailed
Description
The memory module failed because of an irrecoverable error.
Recommended
Response
Action
Review the Embedded System Management (ESM) Log for memory exceptions.
Remove the old memory module and install a new memory module at the
identified location .
807